opto22奥普图  OPTOEMU-SNR-DR2

opto22奥普图 OPTOEMU-SNR-DR2-产品快照

品牌:
opto22奥普图
型号:
OPTOEMU-SNR-DR2

* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.


供应商名称 电话 备注
深圳市格雷创科技有限公司 400-811-6961 微信及邮件咨询,官网:www.gchane.com

OPTO22供应商或现货商入驻,请点击>>

产品介绍

opto22奥普图 OPTOEMU-SNR-DR2

opto22/奥普图 OPTOEMU-SNR-DR2

opto22奥普图

Energy monitoring unit with Demand Response capability (wired Ethernet) ; The OPTOEMU-SNR-DR2 energy monitoring unit monitors the electrical energy used in your facility and then signals electrical equipment to turn on or off in response to a request from an electric utility, demand response aggregator, or curtailment service provider (CSP). To reduce peak energy use that triggers demand charges, electrical equipment loads can also be shed on predefined usage thresholds. OPTOEMU-SNR-DR2 monitors up to two KY or KYZ pulsing devices, such as a pulsing meter or submeter, and up to 64 data inputs from Modbus devices over serial and Ethernet. The unit sends this data to an online service of your choosing, so you can see and analyze energy usage. The unit can also send energy data to control systems and company databases. The unit's four signal relay outputs can be used to automatically respond to a DR event by signaling equipment such as HVAC fans and chillers to turn on or off, or signaling existing energy or building management systems to perform load shedding. Each Form C output can be wired for normally open or normally closed. The OPTOEMU-SNR-DR2 communicates with online services and computer networks over a standard 10/100 Mbps wired Ethernet network. An easy-to-use utility program for configuring the unit is included. You can download this OptoEMU Sensor Manager for free; it also comes on a CD with the unit. If you need wireless communications, see the OPTOEMU-SNR-DR1 . If you need to monitor voltage and current directly from an electrical panel or electrical equipment (not through a pulsing meter or Modbus device), see the OPTOEMU-SNR-3V .

OPTOEMU-SNR-DR1 OPTOEMU-SNR-DR2 Power Requirements 100–240 VAC, 47–63 Hz, 0.4 A maximum, 8 W 100–240 VAC, 47–63 Hz, 0.4 A maximum, 8 W Dimensions Overall 2.45" w x 8.08" h x 4.76" d (6.23 cm x 20.53 cm x 12.09 cm) Overall 2.45" w x 8.08" h x 4.76" d (6.23 cm x 20.53 cm x 12.09 cm) Enclosure Sturdy metal case Sturdy metal case Removable storage MicroSD card slot (for future use) MicroSD card slot (for future use) Backup battery Rechargeable (recharges whenever the unit has power), 3-year power-off data retention Rechargeable (recharges whenever the unit has power), 3-year power-off data retention Ethernet Communication (wired) Two independent 10/100 Mbps Ethernet network interfaces (RJ-45 connectors), each with a sepa­rate IP address (separate subnets). Two independent 10/100 Mbps Ethernet net­work interfaces (RJ-45 connectors), each with a separate IP address (separate subnets). Ethernet Comm (wireless) Wireless LAN interface with separate IP address (separate subnet). Security: AES - Compatible with WPA2 Personal (802.11i); TKIP - Compatible with WPA Personal Frequency 802.11a: 5.180–5.240 GHz, 5.745–5.825 GHz Frequency 802.11b/g: 2.412–2.472 GHz, 2.484 GHz Transmit Power: 15 dBm maximum Antenna Connector: Reverse polarity SMA (RP-SMA or RSMA) Roaming: Supported within an SSID (Service Set Identifier) only No wireless capability Serial Communication One serial port, software configurable for RS-232 (TX, RX, COM, DTR, DCD, RTS, CTS) or RS-485 (2-wire, 4-wire, optional termination, optional biasing). One serial port, software configurable for RS-232 (TX, RX, COM, DTR, DCD, RTS, CTS) or RS-485 (2-wire, 4-wire, optional termination, optional biasing). Indicators Status of unit Wireless: WLAN activity Serial: Receiving, Transmitting (future use) Ethernet interfaces (2): Link, Activity Pulse inputs: On/Off status Mechanical relay outputs: On/Off status Status of unit Serial: Receiving, Transmitting (future use) Ethernet interfaces (2): Link, Activity Pulse inputs: On/Off status Mechanical relay outputs: On/Off status Other features Real-time clock Real-time clock Operating Temperature 0 to 60 °C (32 to 140° F) 0 to 60 °C (32 to 140° F) Storage Temperature -25 to 85 °C (-13 to 185° F) -25 to 85 °C (-13 to 185° F) Humidity 0% to 95% relative humidity, non-condensing 0% to 95% relative humidity, non-condensing Agency Approvals UL, cUL, DFARS Wireless: U.S., FCC Part 15 Subpart C; Canada, IC RSS-210 UL, cUL, CE, RoHS, DFARS Warranty 30 months 30 months Open Circuit Voltage (Switch Open) 15 VDC typical (supplied by OptoEMU Sensor DR) Short Circuit Current (Switch Closed) 7 milliamps nominal Minimum Off Resistance >20 K ohms Maximum Allowable ON Resistance (Wire + Contact Resistance) 500 ohms Turn-on Time 5 msec Turn-off Time 25 msec Input-to-output Isolation 1500 VAC/VDC Minimum Pulse Width >=7 milliseconds Maximum Frequency <=30 Hz Status indicators 1 LED per channel Contact Configuration SPDT relay (with NO and NC contacts) Line Voltage - Range 0–240 VAC or 0–30 VDC Current Rating 100 mA switching @ 0 240 VAC or 0 100 VDC Surge Current 600 mA Minimum Load 0.1 VDC, 5 mA Contact Resistance ≤ 100 milliohms Peak Blocking Voltage 250 VAC/VDC Channel-to-channel isolation 300 VAC (1500 V transient) Turn-on Time 6 milliseconds Turn-off Time 6 milliseconds Temperature 0 to 70 °C, operating -30 to 85 °C, storage Mechanical Life 5 x 10 6 operations Operational Life 1 x 10 3 operations Status indicators 1 LED per channel

Opto 22 Home Products SNAP PAC System Product Selector I/O Energy Management All Not Categorized

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌: