BECKHOFF倍福 BKH-BK7150 I / O系统总线耦合器K-Bus总线耦合器 - 紧凑-产品快照
- 品牌:
- BECKHOFF倍福
- 型号:
- BKH-BK7150
- 重量:
- 0.1 kg
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
毕孚自动化设备贸易(上海)有限公司 | 4008207388 | |
广州永邦机电科技有限公司 | 020-38480341 | |
厦门鹭腾兴电气有限公司 | 0592-5507926 | |
上海欧沁机电工程技术有限公司 | 021-52910098 | |
深圳市丰德锐科技有限公司 | 0755-82526060 |
产品介绍
BECKHOFF倍福 BKH-BK7150 I / O系统总线耦合器K-Bus总线耦合器 - 紧凑
BK7150 Bus Coupler-Compact CC-Link
BECKHOFF倍福
Beckhoff BK7150 Bus Terminal Bus Coupler Compact Bus Coupler CC-Link for up to 64 Bus Terminals (255 with K-bus extension), Data transfer rates: 156kbaud...10Mbaud, Bus interface: 1x open style connector, 5-pin, included, Analog signals: 16 inputs/outputs, Digital signals: 112 inputs/outputs, Max. bytes fieldbus: 32 byte input and 32 byte output General Description The Compact Bus Coupler BK7150 connects the CC-Link system to the electronic terminal blocks, which can be extended in modular fashion. One unit consists of the Bus Coupler, any number of up to 64 terminals and one end terminal. The K-bus extension technology allows the connection of up to 255 spatially distributed Bus Terminals to one Bus Coupler. The Bus Coupler recognises the connected terminals and automatically generates the affiliations of the inputs/outputs to the bytes of the process image. The first input/output signal is inserted in the first bit of one byte (LSB), beginning from the left. The Bus Coupler inserts further signals in this byte. Inputs and outputs are clearly separated. The Bus Coupler automatically begins a further byte if the number of controller inputs or outputs exceeds 8 bits. CC-Link is an open fieldbus system. Baud rates up to 10 Mbaud can be selected via a switch, so that the transfer speed can be adapted to the requirement of the technical process. Complex signal processing for analog I/Os, position measurement The BK7150 Bus Coupler supports the operation of all Bus Terminals. As far as the user is concerned, handling of the analog inputs/outputs is not different to other series. The information is available in the process image of the controller for processing in the form of a byte array. The analog and multi-functional Bus Terminals can be adapted to each specific application using the KS2000 configuration set. Depending on the type, the analog Bus Terminals' registers contain temperature ranges, gain values and linearisation characteristics. With the KS2000, the required parameters can be set on a PC. The Bus Terminals store settings permanently and in a fail-safe manner. Optionally, the Bus Terminals can also be controlled by the control system. Via function blocks (FBs), the programmable logic controller (PLC) or the Industrial PC (IPC) handles configuration of the complete periphery during the start-up phase. If required, the controller can upload the decentrally created configuration data in order to centrally manage and store this data. Therefore, new adjustments are not necessary in the event of replacement of a Bus Terminal. The controller carries out the desired setting automatically after switching on.
I/O Systems Bus Coupler K-Bus Bus Coupler-Compact