Phoenix Contact菲尼克斯 CB E1 24DC/6A NO P 直流断路器-产品快照
- 品牌:
- Phoenix Contact
- 型号:
- CB E1 24DC/6A NO P
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
菲尼克斯(中国)投资有限公司 | 025-52121888 | |
西连电气(上海)有限公司 | 021-80181890 | 工业连接器供应商 |
上海积进自动化设备有限公司 | 021-34273201 | |
上海北上自动化设备有限公司 | 400 7720 262 | |
南京瀚德电子科技有限公司 | 025-86368030 | 电气连接解决方案 |
工控网(北京)电子商务有限公司 | 400-102-5068 | |
上海贸泽电子有限公司 | ||
欧时电子元件(上海)有限公司 | ||
深圳市仕达威实业有限公司 | 400-800-8619 | 德国工业品一站式采购 |
众业达电气股份有限公司 | 4008018988 | |
福州福大自动化科技有限公司 | 0591-28482265 | |
北京京北通宇电子元件有限公司 | 010-82743622 | 国际电子元器件采购服务 |
产品介绍
Phoenix Contact菲尼克斯 CB E1 24DC/6A NO P 直流断路器
CB E1 24DC/6A NO P 2800905 PHOENIX CONTACT Electronic device circuit breaker, 1-pos., active current limitat..
PHOENIX_CONTACT
Electronic device circuit breaker, 1-pos., active current limitation, 1 N/O contact, plug for base element.
General Installation instructions When mounted in rows without convection cooling, the nominal device current should only be led to a maximum of 80% due to the thermal effect during continuous operation (100% operating factor).Special precautionary measures must be taken in systems or machines, to prevent components from restarting (e.g., use of a safety PLC).Parallel connection of multiple circuit breakers is not permitted. Flammability rating according to UL 94 V0 Mounting type On base element Color gray Number of positions 1 Pollution degree 2 Type Male Electrical data Fuse type Electronic Rated surge voltage 0.5 kV Operating voltage 24 V DC 18 V DC ... 30 V DC Nominal current I N 6 A Required backup fuse not required, integrated failsafe element Active current limitation typ. 1.25 x I N Contact type Without electrical isolation Closed circuit current I 0 typ. 8 mA (When switched on) typ. 17 mA (With alarm output) Power dissipation 1.19 W (Nominal operation) Temperature derating 5 A (at 50°C) Tripping method E (electronic) Dielectric strength max. 30 V DC (Load circuit) Voltage drop 130 mV (at I N ) Contact type Without electrical isolation Shutdown time load circuit 130 ms (see time/current characteristic curve) Undervoltage shutdown load circuit < 14 V (typ. OFF) > 17 V (typ. ON) Max. capacitive load load circuit 20000 µF Auxiliary type of contact floating signal contact Minimum auxiliary contact operating voltage 10 V DC Maximum auxiliary contact operating voltage 30 V DC Minimum auxiliary contact operating current 10 mA Maximum auxiliary contact operating current 0.5 A Dimensions Height 45 mm Width 12.3 mm Depth 52 mm Complete module height 90 mm Complete module width 12.3 mm Complete module depth 77.3 mm Ambient conditions Ambient temperature (operation) -25 °C ... 50 °C (non-condensing) Ambient temperature (storage/transport) -40 °C ... 70 °C Humidity test 96 h, 95% RH, 40°C Degree of protection IP30 (Actuation area) Standards and Regulations Standards/specifications UL 2367 UL recognized UL 508 UL/C-UL listed EMV EN 61000-6-3 Noise emission EMV EN 61000-6-2 Noise immunity
Categories: Programmable Logic Controllers Plcs TRABTECH Power and Signal Quality - PHOENIX CONTACT Over Current Protection