Phoenix Contact菲尼克斯 PI-EX-SD-24-48 驱动器-产品快照
- 品牌:
- Phoenix Contact
- 型号:
- PI-EX-SD-24-48
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
菲尼克斯(中国)投资有限公司 | 025-52121888 | |
西连电气(上海)有限公司 | 021-80181890 | 工业连接器供应商 |
上海积进自动化设备有限公司 | 021-34273201 | |
上海北上自动化设备有限公司 | 400 7720 262 | |
南京瀚德电子科技有限公司 | 025-86368030 | 电气连接解决方案 |
工控网(北京)电子商务有限公司 | 400-102-5068 | |
上海贸泽电子有限公司 | ||
欧时电子元件(上海)有限公司 | ||
深圳市仕达威实业有限公司 | 400-800-8619 | 德国工业品一站式采购 |
众业达电气股份有限公司 | 4008018988 | |
福州福大自动化科技有限公司 | 0591-28482265 | |
北京京北通宇电子元件有限公司 | 010-82743622 | 国际电子元器件采购服务 |
产品介绍
Phoenix Contact菲尼克斯 PI-EX-SD-24-48 驱动器
PI-EX-SD-24-48 2865298 PHOENIX CONTACT Ex-i solenoid driver, pluggable. To control intrinsically safe soleno..
PHOENIX_CONTACT
Ex-i solenoid driver, pluggable. To control intrinsically safe solenoid valves, alarm modules as well as simple electric equipment installed in Ex areas. For Group IIC gases, loop-powered. Electrical isolation.
Dimensions Width 12.4 mm Height 145 mm Depth 147 mm Ambient conditions Ambient temperature (operation) -20 °C ... 55 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (relative humidity, non-condensing) Degree of protection IP20 Output data Output characteristic curve: Output resistor ≤ 278 Ω (Internal resistance R i ) Response time < 30 ms Compatible valves Note This is an extract of possible combinations of valves and solenoid drivers. Compatible valve ASCO Coil 195 ASCO Coil 302 (12 V) Bürkert Coil AC 10 standard Bürkert Coil AC 10 high resistance Bürkert Coil AC 21 standard 700 mW / 65°C Bürkert Coil AC 21 high resistance 700 mW / 65°C Bürkert Coil AC 21 standard 900 mW / 45°C Bürkert Coil AC 21 high resistance 900 mW / 45°C Bürkert Coil AC 21 standard 900 mW / 60°C Bürkert Coil AC 21 high resistance 900 mW / 60°C Bürkert Coil G1 642735 standard 800 mW / 40°C Bürkert Coil G1 642735 high resistance 800 mW / 40°C Bürkert Coil G1 642735 standard 1000 mW / 40°C Bürkert Coil G1 642735 high resistance 1000 mW / 40°C FESTO Coil MFH-...IA-SA-EX GBXE022AIAD03 FESTO Coil (J)MFH-...BIA-SA-EX GBXE022AIAD03 Norgren Herion Coil 2050 Norgren Herion Coil 2051 Norgren Herion Coil 2052 Norgren Herion Coil 2053 Norgren Herion Coil 2080 / 2082 Norgren Herion Coil 2081 / 2083 Norgren Herion Coil 2084 Norgren Herion Coil 3039 Nass Coil 1259 30.1-00 Nass Coil 1259 50.1-00 Parker Coil VZ07 488650.01 Parker Coil VZ33 494035.10 Parker Coil VZ08 488660.01 Parker Coil VZ09 488670.01 Parker Coil VZ95 482160.01 EEx ia IIB T6 Parker Coil VZ23 482870.01 Samson Coil 3701-12 (12 V) Samson Coil 3701-13 (24 V) Samson Coil 3963-12 (12 V) Samson Coil 3963-13 (24 V) Samson Coil 3964-12 (12 V) Samson Coil 3964-13 (24 V) Seitz Pilot valve PV 12F73 Ci oH Seitz Pilot valve PV 12F73 Xi oH Seitz Pilot valve PV 12F73 Xi oH-2 Seitz Solenoid coil 11 G 52 Power supply Max. current consumption < 110 mA (at 24 V) Power consumption max. 1.5 W (at 24 V) General Maximum temperature coefficient 0.01 %/K Status display Yellow LED (status display) Red LED (line errors) Flammability rating according to UL 94 V0 Housing material PBT and polyamide PA non-reinforced Color green Designation Input/output Electrical isolation 375 V (Peak value as per EN 50020 / EN 60079-11) 2.5 kV (50 Hz, 1 min., test voltage) Conformance CE-compliant ATEX Ex II (1) GD [Ex ia] IIC / IIB / IIA Ex II 3 G Ex nA II T4 X Functional Safety (SIL) SIL 3 Safety characteristic data Integrity requirement IEC 61508 - Low demand Equipment type Type A Safety Integrity Level (SIL) 3 Safe Failure Fraction (SFF) 100 % λ SU 2.84 x 10 -7 (284 FIT) λ SD 0 λ DU 0 λ DD 0 Probability of a hazardous failure on demand (PFD AVG ) 0 (1 year) 0 (5 years) 0 (10 years) Diagnostic coverage (DC) DC S = 0%, DC D = 0% Safety data Max. output voltage U o 27.7 V Max. output current I o 101 mA Max. output power P o 697 mW Group IIA Max. external inductivity L o 20 mH Max. external capacity C o 0.44 µF Group IIB Max. external inductivity L o 2 mH Max. external capacity C o 0.29 µF Group IIC Max. external inductivity L o 0.5 mH Max. external capacity C o 0.067 µF Max. ratio L o /R o 51.1 µH/Ω Additional text Please follow the technical data regarding the connecting cables used. Safety-related maximum voltage U m 250 V AC (125 V DC)
Categories: Programmable Logic Controllers Plcs INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT MSR Components for Ex areas - PHOENIX CONTACT