Phoenix Contact菲尼克斯 EMM 3-230AC/500AC-IFS 交流电机-产品快照
- 品牌:
- Phoenix Contact
- 型号:
- EMM 3-230AC/500AC-IFS
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
菲尼克斯(中国)投资有限公司 | 025-52121888 | |
西连电气(上海)有限公司 | 021-80181890 | 工业连接器供应商 |
上海积进自动化设备有限公司 | 021-34273201 | |
上海北上自动化设备有限公司 | 400 7720 262 | |
南京瀚德电子科技有限公司 | 025-86368030 | 电气连接解决方案 |
工控网(北京)电子商务有限公司 | 400-102-5068 | |
上海贸泽电子有限公司 | ||
欧时电子元件(上海)有限公司 | ||
深圳市仕达威实业有限公司 | 400-800-8619 | 德国工业品一站式采购 |
众业达电气股份有限公司 | 4008018988 | |
福州福大自动化科技有限公司 | 0591-28482265 | |
北京京北通宇电子元件有限公司 | 010-82743622 | 国际电子元器件采购服务 |
产品介绍
Phoenix Contact菲尼克斯 EMM 3-230AC/500AC-IFS 交流电机
EMM 3-230AC/500AC-IFS 2297507 PHOENIX CONTACT Electronic motor management for operation with external curren..
PHOENIX_CONTACT
Electronic motor management for operation with external current transformer- active power measurement for overload and underload monitoring of motors and systems for optimum protection for all performance classes. Freely parameterizable switching and signaling thresholds.
Dimensions Width 22.5 mm Height 99 mm Depth 114.5 mm Ambient conditions Ambient temperature (operation) -25 °C ... 70 °C Ambient temperature (storage/transport) -25 °C ... 70 °C Degree of protection IP20 Input data Input name Device supply Rated control circuit supply voltage U S 230 V AC Voltage range with reference to U S 0.4 ... 1.1 Rated control supply current I S 10 mA Switching threshold 48 V AC (“0” signal) 96 V AC (“1” signal) Operating voltage display Green LED Status display LED yellow right rotation (R), LED yellow left rotation (L), LED green data communication Indication Red LED Input name Digital inputs (IN1 - IN4) Rated actuating voltage U C 230 V AC Rated actuating current I C 3.5 mA Input name Voltage measuring input V1, V2, V3 Input voltage range 42 V AC ... 575 V AC Typical input current at U N < 0.5 mA Input name Current measuring input L1/T1, L2/T2, L3/T3 Typical input current at U N 5 A (Secondary external converter) Output data Output name Acknowledging contacts O1-O4 Note The meaning of the acknowledgement outputs can be freely parameterized, see user manual Number of outputs 4 Nominal output voltage 230 V AC (relay output/500 mA) Continuous load current 500 mA Measuring technology and signaling contact Designation Current measurement Measuring via External push-through current transformers connected upstream Basic accuracy typ. 0.5 % Designation Voltage measurement/phase-to-neutral voltage Voltage range 0 V AC ... 350 V AC (Phase-to-neutral voltage) Basic accuracy typ. 0.75 % Designation Power measurement Power range 4.5 kW () Basic accuracy typ. 2 % Connection data, control circuit Connection name Control circuits Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 General Test voltage input/output 8 kV Mounting position Vertical (horizontal DIN rail) Assembly instructions In rows with zero spacing Operating mode 100% operating factor Designation Air clearances and creepage distances between the power circuits Standards/regulations DIN EN 50178 Insulation safe isolation Pollution degree 2 Overvoltage category III Designation Standards/regulations Standards/regulations EN 60947 EN 60947-4-2
Categories: Core End Sleeves Cable Crimp INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT Solid state relays and power electronics. Relay - PHOENIX CONTACT