产品介绍
Phoenix Contact菲尼克斯 VAL-MS 580/3+0 交流稳压电源
VAL-MS 580/3+0 2920450 PHOENIX CONTACT Surge arrester for 4-conductor power supply systems (L1, L2, L3, PEN)..
PHOENIX_CONTACT
Surge arrester for 4-conductor power supply systems (L1, L2, L3, PEN), consisting of a base element and protective connectors, for mounting on NS 35.
Dimensions Height 90 mm Width 53.4 mm Depth 44 mm Horizontal pitch 3 Div. Ambient conditions Degree of protection IP20 (only when all terminal points are used) Ambient temperature (operation) -40 °C ... 80 °C Ambient temperature (storage/transport) -40 °C ... 80 °C Altitude ≤ 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 25g (half sinus / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) General Standards/specifications IEC 61643-11 2011 EN 61643-11 2012 IEC test classification II T2 EN type T2 IEC power supply system TN-C IT Number of ports One SPD design Voltage-limiting type Mode of protection L-PEN L-PE Mounting type DIN rail: 35 mm Color jet black RAL 9005 Housing material PA 6.6 PBT Pollution degree 2 Distance between live and grounded parts 5 mm Flammability rating according to UL 94 V-0 Type DIN rail module, two-section, divisible Number of positions 3 Surge protection fault message optical Additional descriptions Note Usable in all low-voltage systems between L-N or L-PEN.Only usable in IT Systems between L-PE, if the exposed-conductive-parts (bodies) of the equipment of the low-voltage installation is connected to the earthing arrangement of the transformer substation. (interconnected earthing arrangement of the HV-transformer substation with the bodies of the LV-installation. R E = R A accordance to IEC 60364-4-442 / VDE 0100-442 Fig. 44D / Example a) Protective circuit Nominal voltage U N 400/690 V AC (TN-C) 500 V AC (IT) Nominal frequency f N 50 Hz (60 Hz) Maximum continuous voltage U C 580 V AC Rated load current I L 80 A Residual current I PE ≤ 0.75 mA Standby power consumption P C ≤ 450 mVA Nominal discharge current I n (8/20) µs 15 kA Maximum discharge current I max (8/20) µs 30 kA Short-circuit current rating I SCCR 25 kA Voltage protection level U p ≤ 2.5 kV Residual voltage U res ≤ 2.5 kV (at I n ) ≤ 2.3 kV (at 10 kA) ≤ 2.1 kV (at 5 kA) ≤ 1.9 kV (at 3 kA) TOV behavior at U T (L-PEN) 690 V AC (5 s / withstand mode) Response time t A ≤ 25 ns Max. backup fuse with branch wiring 125 A AC (gG) Max. backup fuse with V-type through wiring 80 A AC (gG) Connection data Connection method Screw connection Conductor cross section flexible min. 1.5 mm² Conductor cross section flexible max. 25 mm² Conductor cross section solid min. 1.5 mm² Conductor cross section solid max. 35 mm² Conductor cross section AWG 15 ... 2 Screw thread M5 Tightening torque 4.5 Nm Stripping length 16 mm UL specifications SPD Type 4CA Maximum continuous operating voltage MCOV (L-L) 1160 V AC Maximum continuous operating voltage MCOV (L-G) 580 V AC Nom. voltage 400/690 V AC Mode of protection L-L L-G Power distribution system 3D Nominal frequency 50/60 Hz Measured limiting voltage MLV (L-L) 4270 V Measured limiting voltage MLV (L-G) 2310 V Nominal discharge current I n (L-L) 10 kA Nominal discharge current I n (L-G) 10 kA
Categories: Overvoltage Protection Over Voltage TRABTECH Power and Signal Quality - PHOENIX CONTACT Surge protection - PHOENIX CONTACT