EATON伊顿 DILM25-10(RDC60) 直流接触器-产品快照
- 品牌:
- EATON
- 型号:
- DILM25-10(RDC60)
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 DILM25-10(RDC60) 直流接触器
DILM25-10(RDC60) 277147 EATON MOELLER Contactor, 3p + 1N / O, 11kW / 400V / AC3
EATON - MOELLER
Contactor, 3p + 1N / O, 11kW / 400V / AC3
Delivery programme Product range Contactors Application Contactors for Motors Subrange Contactors up to 170 A, 3 pole Utilization category AC-1: Non-inductive or slightly inductive loads, resistance furnaces NAC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching General Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated Operations x 10 6 10 DC operated Operations x 10 6 10 Operating frequency, mechanical AC operated Operations/h 5000 DC operated Operations/h 5000 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open °C -25 - +60 Enclosed °C - 25 - 40 Storage °C - 40 - 80 Mounting position Technical data for design verification Rated operational current for specified heat dissipation I n A 25 Heat dissipation per pole, current-dependent P vid W 1.4 Equipment heat dissipation, current-dependent P vid W 4.2 Static heat dissipation, non-current-dependent P vs W 0.9 Heat dissipation capacity P diss W 0 Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 60 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 (Show features) (Hide features) Low-voltage industrial components (EG000017) / Power contactor, AC switching (EC000066) Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Power contactor, AC switching ( [email protected] [AAB718012]) Rated control supply voltage Us at AC 50HZ V 0 - 0 Rated control supply voltage Us at AC 60HZ V 0 - 0 Rated control supply voltage Us at DC V 48 - 60 Voltage type for actuating DC Rated operation current Ie at AC-1, 400 V A 45 Rated operation current Ie at AC-3, 400 V A 25 Rated operation power at AC-3, 400 V kW 11 Rated operation current Ie at AC-4, 400 V A 13 Rated operation power Ie at AC-4, 400 V kW 6 Modular version No Number of auxiliary contacts as normally open contact 1 Number of auxiliary contacts as normally closed contact 0 Type of electrical connection of main circuit Screw connection Number of normally closed contacts as main contact 0 Number of main contacts as normally open contact 3 Approvals Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking UL File No. E29096 UL Category Control No. NLDX CSA File No. 012528 CSA Class No. 2411-03, 3211-04 North America Certification UL listed, CSA certified Specially designed for North America No Characteristics IL03407014Z (AWA2100-2127) Contactor >>
Categories: Contactor Relays DIL Contactors up to 170A - EATON - MOELLER