EATON伊顿 EASY600-POW 交流稳压电源-产品快照
- 品牌:
- EATON
- 型号:
- EASY600-POW
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 EASY600-POW 交流稳压电源
EASY600-POW 262399 EATON MOELLER Power Supply 100-240VAC / 24VDC (4.2A)
EATON - MOELLER
Power Supply 100-240VAC / 24VDC (4.2A)
Delivery programme Product range Control relays easyRelay Multi-function-display MFD-Titan Product range Switched-mode power supply units easyPOW Description primary chopper controlled Phases Single-phase Input voltage range 85 - 264 V AC Nominal input voltage 100 - 240 V AC Rated output voltage 24 V DC (± 3%) Rated output current A 4.2 For use with easy500 easy700 easy800 MFD-CP8 EC4P ES4P Technical data General Standards EN 55011, EN 55022, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27 Dimensions (W x H x D) mm 107.5 (6 PE) x 90 x 58 Weight kg 0.3 Mounting Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories) Terminal capacities Solid mm 2 0.2/4 (AWG 22 - 12) Flexible with ferrule mm 2 0.2/2.5 (AWG 22 - 12) Standard screwdriver mm 3.5 x 0.8 Max. tightening torque Nm 0.6 Climatic environmental conditions Operating ambient temperature °C -25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 Condensation Take appropriate measures to prevent condensation Storage °C - 40 - 70 Relative humidity, non-condensing (IEC/EN 60068-2-30) % Air humidity, non-condensing, min. % 5 Air humidity, non-condensing, max. % 95 Air pressure (operation) hPa 795 - 1080 Max. installation altitude above sea level, observe derating with higher altitudes m 2000 Ambient conditions, mechanical Protection type (IEC/EN 60529, EN50178, VBG 4) IP20 Vibrations (IEC/EN 60068-2-6) Hz Constant amplitude 0.15 mm Hz 10 - 57 Constant acceleration 2 g Hz 57 - 150 Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms Impacts 18 Drop to IEC/EN 60068-2-31 Drop height mm 50 Free fall, packaged (IEC/EN 60068-2-32) m 1 Mounting position Horizontal, terminals top Electromagnetic compatibility (EMC) Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD) kV Air discharge kV 8 Contact discharge kV 6 Electromagnetic fields (RFI) to IEC EN 61000-4-3 V/m 10 Radio interference suppression EN 55011 Class B, EN 55022 Class B Burst pulses (IEC/EN 61000-4-4, level 3) kV 2 Power pulses (surge) (IEC/EN 61000-4-5) kV 2 (supply cables, symmetrical) High-energy pulses (surge) (IEC/EN 61000-4-5, level 2), 24 V kV 0.5 (outgoer cables symmetrical, EASY…DC) Immunity to line-conducted interference to (IEC/EN 61000-4-6) V 10 Surge voltage (EN 50178), 24 V kV 6 Insulation resistance Clearance in air and creepage distances EN 50178 Insulation resistance EN 50178 Protection class U out to U in Class II to IEC 60536 Potential isolation primary/secondary Yes, SELV (VDE 0100 Part 410; IEC 60364-4-41, HD 384.4.41 S2) EN 60950, EN 50178 Input voltage Rated input voltage DC V 100/120/230/240 (-15/+10 %) Protective switches AC FAZ-C2/1 oder FAZ-B6/1 Rated input voltage DC V DC 85 264 DC protective switches FAZ-C2/1-DC Voltage range V AC 85 - 264 Frequency range Hz 47 - 63 Mains failure bridging 115/230 V (IEC/EN 61000-4-11) ms > 20/> 40 Fuse 115/230 V A 2/1 slow Rating data Efficiency % > 85 Power consumption W Normally 115 Power loss P W Normally 18 Note on heat dissipation Current consumption at 240 V DC Input current Input current nominal115/240 V A Approx. 1/0.5 Inrush current at 25 °C 230 V A < 30 Output voltage 24 V DC Rated value V DC 24 Tolerance % ± 3 Switching peaks 115/230 mV PP < 5 Effect of input voltage % ± 1 Effect with 25 - 100 % load change % ± 2 Can be connected in parallel to increase power Yes Output current 24 V DC Output current A 0 - 4.2 Effectiveness of current limitation A > 4.8 Reduction of output voltage after current limitation V < 18 Overload proof Yes, by current limitation Proof against sustained short circuit Yes, hickup mode, approx. 2 Hz Displays Indication of output voltage (LED, continuous green light = OK) V DC 24 Design verification as per IEC/EN 61439 (Show features) (Hide features) Technical data for design verification Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 55 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Meets the product standard's requirements. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 (Show features) (Hide features) PLC's (EG000024) / PLC system power supply (EC000599) Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / SPS system power supply ( [email protected] [AKE532011]) Input voltage at AC 50 Hz V 85 - 264 Input voltage at AC 60 Hz V 85 - 264 Input voltage at DC V 0 - 0 Type of voltage (input voltage) AC Max. input current AC 50 Hz A 0 Max. input current AC 60 Hz A 0 Max. input current DC A 0 Type of output voltage DC Output voltage at AC 50 Hz V 0 - 0 Output voltage at AC 60 Hz V 0 - 0 Output voltage at DC V 0 - 0 Max. output current AC 50 Hz A 0 Max. output current AC 60 Hz A 0 Max. output current DC A 4.2 Redundancy No Suitable for safety functions No Width mm 72 Height mm 90 Depth mm 60 Approvals Product Standards IEC/EN see Technical Data; UL 508; CSA C22.2 No. 107.1-01; CE marking UL File No. E300415 UL Category Control No. NMTR, NMTR7 CSA File No. UL report applies to both US and Canada CSA Class No. 3211-87, 3211-07 North America Certification UL listed, certified by UL for use in Canada Degree of Protection IEC: IP20, UL/CSA Type: - Dimensions IL05012003Z (AWA2727-1869) Power supply unit >>
Categories: