Siemens西门子 3RT1024-3AL20 交流接触器-产品快照
- 品牌:
- Siemens
- 型号:
- 3RT1024-3AL20
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
众业达电气(深圳)有限公司 | 0755-89314987 | irene.li@zyd.cn,13509669211 |
大连鼎宏科技有限公司 | 0411-83693111 | |
东莞市欧能自动化设备有限公司 | 18680502757 | |
福建萤光电气科技发展有限公司 | 18359060969 | |
福州福大自动化科技有限公司 | 0591-28482265 | |
广州锋力五金机电有限公司 | 020-87359185 | |
广州汇尼克机电设备有限公司 | 020-85549829 | |
广州市黄埔区科技开发总公司 | ||
海格曼商贸(上海)有限公司 | 4008215282 | |
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
深圳市行健自动化股份有限公司 | 0755-86336499 | |
深圳市昊普锐科技有限公司 | 0755-82127363 | |
深圳市朗助机电有限公司 | 0755-83975718 | |
深圳市曼伯特实业发展有限公司 | 0755-82032366 | |
苏州工品汇信息科技有限公司 | 4000496999 |
产品介绍
Siemens西门子 3RT1024-3AL20 交流接触器
3RT1024-3AL20 SIEMENS CONTACTOR, AC-3 5,5 KW/400 V, AC 230 V 50/60 HZ, 3-POLE, SIZE S0, CAGE CLAMP CONNECTI..
SIEMENS
CONTACTOR, AC-3 5,5 KW/400 V, AC 230 V 50/60 HZ, 3-POLE, SIZE S0, CAGE CLAMP CONNECTION
product brand name SIRIUS Product designation power contactor General technical data: Size of contactor S0 Degree of pollution 3 Protection class IP ● on the front IP20 ● of the terminal IP20 Mechanical service life (switching cycles) ● of contactor typical 10 000 000 ● of the contactor with added electronics-compatible auxiliary switch block typical 5 000 000 ● of the contactor with added auxiliary switch block typical 10 000 000 Ambient conditions: Installation altitude at height above sea level maximum 2 000 m Ambient temperature ● during operation -25 ... +60 °C Main circuit: Number of NO contacts for main contacts 3 Number of NC contacts for main contacts 0 Operating current ● at AC-1 at 400 V — at ambient temperature 40 °C rated value 40 A ● at AC-1 — up to 690 V at ambient temperature 40 °C rated value 40 A — up to 690 V at ambient temperature 60 °C rated value 35 A ● at AC-3 — at 400 V rated value 12 A Operating current ● at 1 current path at DC-1 — at 24 V rated value 35 A — at 110 V rated value 4.5 A ● with 2 current paths in series at DC-1 — at 24 V rated value 35 A — at 110 V rated value 35 A ● with 3 current paths in series at DC-1 — at 24 V rated value 35 A — at 110 V rated value 35 A Operating current ● at 1 current path at DC-3 at DC-5 — at 24 V rated value 20 A — at 110 V rated value 2.5 A ● with 2 current paths in series at DC-3 at DC-5 — at 110 V rated value 15 A — at 24 V rated value 35 A ● with 3 current paths in series at DC-3 at DC-5 — at 110 V rated value 35 A — at 24 V rated value 35 A Operating power ● at AC-1 — at 400 V rated value 23 kW ● at AC-2 at 400 V rated value 5.5 kW ● at AC-3 — at 400 V rated value 5.5 kW — at 500 V rated value 7.5 kW — at 690 V rated value 7.5 kW Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor 0.5 W Control circuit/ Control: Type of voltage of the control supply voltage AC Control supply voltage at AC ● at 50 Hz rated value 230 V ● at 60 Hz rated value 230 V Control supply voltage frequency 1 rated value 50 Hz Control supply voltage frequency 2 rated value 60 Hz Operating range factor control supply voltage rated value of magnet coil at AC ● at 50 Hz 0.8 ... 1.1 ● at 60 Hz 0.85 ... 1.1 Apparent pick-up power of magnet coil at AC 64 V·A Inductive power factor with closing power of the coil 0.72 Apparent holding power of magnet coil at AC 8.4 V·A Inductive power factor with the holding power of the coil 0.24 Auxiliary circuit: Number of NC contacts ● for auxiliary contacts — instantaneous contact 0 Number of NO contacts ● for auxiliary contacts — instantaneous contact 0 Operating current at AC-12 maximum 10 A Operating current at AC-15 ● at 230 V rated value 6 A ● at 400 V rated value 3 A Operating current at DC-12 ● at 60 V rated value 6 A ● at 110 V rated value 3 A ● at 220 V rated value 1 A Operating current at DC-13 ● at 24 V rated value 10 A ● at 60 V rated value 2 A ● at 110 V rated value 1 A ● at 220 V rated value 0.3 A Contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) Short-circuit protection Design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required fuse gL/gG: 63 A — with type of assignment 2 required fuse gL/gG: 25 A ● for short-circuit protection of the auxiliary switch required fuse gL/gG: 10 A Installation/ mounting/ dimensions: Mounting type screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 ● Side-by-side mounting Yes Height 85 mm Width 45 mm Depth 90 mm Required spacing ● for grounded parts — at the side 6 mm Connections/Terminals: Type of electrical connection ● for main current circuit screw-type terminals ● for auxiliary and control current circuit spring-loaded terminals Type of connectable conductor cross-sections ● for main contacts — solid 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), max. 2x 10 mm² — single or multi-stranded 2x (1 ... 2,5 mm²), 2x (2,5 ... 6 mm²), max. 2x 10 mm² — finely stranded with core end processing 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²) ● at AWG conductors for main contacts 2x (16 ... 12), 2x (14 ... 10), 1x 8 Type of connectable conductor cross-sections ● for auxiliary contacts — solid 2x (0.25 ... 2.5 mm²) — finely stranded with core end processing 2x (0.25 ... 1.5 mm²) — finely stranded without core end processing 2x (0.25 ... 2.5 mm²) ● at AWG conductors for auxiliary contacts 2x (24 ... 14)
Categories: Contactors for switching motors