产品介绍
ABB UA26-30-10 交流接触器
UA26-30-10 1SBL241022R3410 ABB UA26-30-10 175V 50Hz / 208V 60Hz Contactor
ABB
UA26-30-10 175V 50Hz / 208V 60Hz Contactor
UA26 3-pole contactors for capacitor switching, can be used for the switching of capacitor banks whose inrush current peaks are less than or equal to 100 times nominal rms current. The table below gives the permissible powers according to operational voltage and temperature close to the contactor. It also specifies the maximum peak current Î values accepted by the contactor. The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. In these conditions, electrical durability of contactors is equal to 100 000 operating cycles. The UA.. series 3-pole contactors are of the block type design. - Main poles and auxiliary contacts: 3 main poles, 1 built-in auxiliary contact - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available. Ordering EAN: 3471522069344 Minimum Order Quantity: 1 piece Customs Tariff Number: 85369085 Dimensions Product Net Width: 54 mm Product Net Depth: 93.6 mm Product Net Height: 90 mm Product Net Weight: 0.600 kg Container Information Package Level 1 Units: 1 piece Package Level 1 Width: 101 mm Package Level 1 Length: 115 mm Package Level 1 Height: 61 mm Package Level 1 Gross Weight: 0.6 kg Package Level 1 EAN: 3471522069344 Package Level 2 Units: 63 piece Package Level 3 Units: 576 piece Technical Number of Main Contacts NO: 3 Number of Main Contacts NC: 0 Number of Auxiliary Contacts NO: 1 Number of Auxiliary Contacts NC: 0 Rated Operational Voltage: Main Circuit 690 V Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz Conventional Free-air Thermal Current (I th ): acc. to IEC 60947-5-1, q = 40 °C 16 A Rated Operational Current AC-15 (I e ): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 1.5 ... 1.8 A Rated Short-time Withstand Current (I cw ): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 210 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 45 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 90 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 110 A for 0.1 s 140 A for 1 s 100 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A Rated Operational Current DC-13 (I e ): (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A Rated Insulation Voltage (U i ): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V Rated Impulse Withstand Voltage (U imp ): 8 kV Maximum Mechanical Switching Frequency: 3600 cycles per hour Coil Operating Limits: (acc. to IEC 60947-4-1)0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C Rated Control Circuit Voltage (U c ): 50 Hz 175 V 60 Hz 208 V Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 50 Hz 120 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 140 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 3 W Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 3 W Average Holding Value 50 Hz 12 V·A Average Holding Value 50 Hz 3 W Average Holding Value 60 Hz 12 V·A Average Holding Value 60 Hz 3 W Average Pull-in Value 50 Hz 120 V·A Average Pull-in Value 60 Hz 140 V·A Operate Time: Between Coil Energization and NO Contact Closing 8 ... 21 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Connecting Capacity-Main Circuit: Flexible with Cable End0.75 ... 4 mm² Rigid Cable1.5 ... 6 mm² Connecting Capacity-Auxiliary Circuit: Flexible with Cable End0.75 ... 2.5 mm² Rigid Cable1 ... 4 mm² Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 Connecting terminals (delivered in open position) Main poles: M 4 (+,-) pozidriv 2 screws with cable clamp Terminal Type: Screw Terminals Environmental Ambient Air Temperature: Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C Near Contactor for Operation in Free Air (Uc) -40 ... +70 °C Close to Contactor for Storage -60 ... +80 °C Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II Maximum Operating Altitude Permissible: 3000 m RoHS Status: No declaration needed Certificates and Declarations (Document Number) CB Certificate: CB_FR2880_60002378 CCC Certificate: CCC_2003010304060095 CSA Certificate: CSA_1033838_LR056745 cUL Certificate: UL_071301E39231 Declaration of Conformity - CE: 1SBD250809C2000 EAC Certificate: EAC_RU C-FR ME77 B01010 GOST Certificate: GOST_POCCFRME77B07175 RoHS Information: 1SBC101059D0201 UL Certificate: UL_071301E39231 Classifications ETIM 5: EC001079 - Capacitor magnet contactor UNSPSC: 39121529
Categories: Contactor Relays Contactors and overload relays Contactors "A" FRCTLP