EATON伊顿 RASP-304AI1S0-C320S1 pid控制器-产品快照
- 品牌:
- EATON
- 型号:
- RASP-304AI1S0-C320S1
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 RASP-304AI1S0-C320S1 pid控制器
RASP-304AI1S0-C320S1 169806 EATON MOELLER RASP-304AI1S0-C320S1 Rapid Link speed controller up to 3.3 A
EATON - MOELLER
RASP-304AI1S0-C320S1 Rapid Link speed controller up to 3.3 A
Delivery programme Product range Speed controller Description integrated PTC thermistor monitoringand Thermoclick with safe isolation Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation Connection of supply voltage via adapter cable on round or flexible busbar junction Diagnostics and reset on device and via AS-Interface with AUTO - OFF/RESET - HAND key switches 3 fixed speeds and 1 potentiometer speed can be switched over from U/f to (vector) speed control Two sensor inputs through M12 sockets with Y-connector (optional) for creep speed with selector switch REV - OFF - FWD selectable: with quick stop on failure of the external 24 V Repair switch without manual override switch Fan without fan Braking resistance without braking resistance Rated operational voltage U e 400 V AC, 3-phase Output voltage with V e U 2 400 V AC, 3-phase Mains voltage (50/60Hz) U LN V 380 (-10%) - 480 (+10%) At 150% overload I e A 3.3 Control voltage external brake (50/60 Hz) V AC 400 Mains voltage (50/60Hz) U LN V 380 (-10%) - 480 (+10%) assigned motor rating P Note at 400 V, 50 Hz 150 % Overload P kW 1.1 Note at 440 - 480 V, 60 Hz 150 % Overload P HP 1.5 Note for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm -1 at 50 Hz or 1800 min -1 at 60 Hz AS-Interface profile cable S-7.4 for 31 modules Instructions for actuation of motors with mechanical brake Technical data General Standards EN 61800-5-1 EN 61800-3 Directive 2002/95/EG (RoHS) CE approval Climatic proofing ρ w % < 95%, non-condensing IEC/EN 50178 Ambient temperature Storage ϑ °C -30 - +70 Overvoltage category III Rated impulse withstand voltage U imp kV 2 Radio interference level Environment (EMC) 2. Environment, Class C3 maximum motor cable length I m 5 Mechanical shock resistance g 1000 shocks per shaft, semi-sinusoidal 15 g/11 ms IEC/EN 60068-2-27 Vibration Oscillation frequency: 10 - 150 Hz Amplitude 0.15 mm: 6 Hz Amplitude transition frequency on acceleration: 57 Hz IEC/EN 60068-2-6 Mounting position Vertical Altitude m 0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 2000 m Degree of Protection IP65 IEC/EN 60529 Main circuit Supply Rated operational voltage U e 400 V AC, 3-phase Mains voltage (50/60Hz) U LN V 380 (-10%) - 480 (+10%) Input current (150% overload) I LN A 4 System configuration AC voltage Center-point earthed star network (TN-S network) Phase-earthed AC supply systems are not permitted. Supply frequency f LN Hz 50/60 Frequency range f LN Hz 47 - 66 Hz (± 0%) Mains switch-on frequency Maximum of one time every 60 seconds Mains current distortion THD % > 120 Rated conditional short-circuit current I q kA < 5 Short-circuit protection for output circuits, external Type 1 coordination via the power bus' feeder unit Power section Function Frequency inverter with internal DC link and IGBT inverter On-delay t ON ms 30 - 50 Off-delay t OFF ms 15 - 35 Overload current (150% overload) I L A 5 Note regarding overload current at 40 °C Note about max. starting current for 2 seconds at 40 °C Output voltage with V e U 2 400 V AC, 3-phase Output Frequency f 2 Hz 0 - 50/60 (max. 320) Switching frequency f PWM kHz 6 adjustable 1.5 - 16 Operation Mode linear, parameterizable Frequency resolution (setpoint value) Δf Hz 0.01 Rated operational current At 150% overload I e A 3.3 Note Rated operational current at an operating frequency of 6 kHz and an ambient air temperature of +40 °C Motor current limit I A 0.66 - 6.6 adjustable Efficiency η % 0.95 Maximum leakage current to ground (PE) without motor I PE mA 3.5 Fan internal, temperature controlled optional RASP-FAN-S1 on heat sink, temperature-controlled Fitted with without manual override switch without fan without braking resistance Motor feeder Note for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm -1 at 50 Hz or 1800 min -1 at 60 Hz Note at 400 V, 50 Hz 150 % Overload P kW 1.1 Note at 440 - 480 V, 60 Hz 150 % Overload P HP 1.5 Actuator for external motor brake Breaking voltage U V 400 V AC -15% / +10% Braking current I A ≤ 0.6 A (max. 6 A for 120 ms) Braking function DC braking % I/I e border=1> >IL03406020Z Rapid Link: Speed Control Unit MN03406003Z Rapid Link 4.0 >border=1> >MN03406003Z Rapid Link 4.0 - Deutsch >border=1> >MN03406003Z Rapid Link 4.0 - English >border=1>>CA04020001Z-DE Sortimentskatalog: Antriebstechnik effizient gestalten, Motoren starten und steuern
Categories: