EATON伊顿 CS-2520/150-产品快照
- 品牌:
- EATON
- 型号:
- CS-2520/150
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 CS-2520/150
CS-2520/150 111646 EATON MOELLER Wall enclosure, +mounting plate, HxWxD 250x200x150mm
EATON - MOELLER
Wall enclosure, +mounting plate, HxWxD=250x200x150mm
Delivery programme Product range Wall-mounting housing CS Product function Wall-mounting housing with mounting plate Degree of Protection IP66 IP23 (with ventilating plates) Description Foamed polyurethane sealing throughout. Impact resistance category IK09 to EN 62262. Sheet steel mounting plate Bottom plate with foamed gasket. Single door, door stop on the right, door opening angle 120° Door hinge pins with quick change technology. Standardized locking system with sash fastener. Powder coating RAL 7035 inside and outside Material Steel plate Dimensions Width mm 200 Height mm 250 Depth mm 150 Locks Number 1 Hinges Number 2 Door profile molding Number 1 Flange plates Width x Depth mm 112 x 182 Max. F3A flanges Number - Mounting plates Height mm 220 Width mm 150 Weight kg 3.4 Information about equipment supplied Lock, 3 mm double ward key Including M6 threaded welded studs for earth conductor connections in the door Technical data General Standards IEC/EN 60529, IEC 62262, IEC/EN 62208 RoHS In accordance with Directive 2002/95/EC of the European Parliament and Council RoHS (in accordance with Directive 2002/95/EC of the European Parliament and Council) yes Climatic proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30 Ambient temperature °C -40 - +70 Degree of Protection IP66 IP23 (with ventilating plates) Installation conditions Indoor-/outdoor installation Power loss Power loss P v [W] for fully enclosed sheet steel enclosure CS without internal partitions for wall mounting. Example: max. ambient temperature 35°C; Overtemperature ΔT = 20 K; Relative humidity = 75%. Max. heat dissipation Individual enclosure for wall mounting P V W 11 Starting enclosure for wall mounting P V W 10 Middle enclosure for wall mounting P V W 9 Material characteristics Material Steel plate Surface treatment Structured powder spray polyester based paint finish Surface finish Semi-textured Colour RAL 7035, light grey Finish Gloss Material thickness mm Body mm 1.2 Mounting plate mm 2 Door mm 1 Bottom plate mm 1.5 Material properties Mechanical Impact resistance IK09 according to EN 62262 max. assembly weights Total of Weight of fitted components kg 150 Mounting plate kg 125 Door kg 25 500 kg payload, when brackets fitted in all four enclosure corners (vertically or horizontally) and the weights are symmetrically distributed within the enclosure. Description/standard features Construction Canted and seam welded, including two M6 threaded bolts for earth conductor connections inside the enclosure. Back plate 9 mm drilling dimensions for wall mounting Side plates Without apertures Top plate Without apertures Bottom plate Enclosed, foamed gasket, can be unscrewed for F3A-… flanges or for assembly by user Mounting plate, material Sheet steel, hot-galvanized Door, Engineering Including M6 threaded welded studs for earth conductor connections in the door: Information about equipment supplied Lock, 3 mm double ward key Including M6 threaded welded studs for earth conductor connections in the door If electrical apparatus is to be installed in the door, a continuous, permanent protective ground contactor connection must be established with a protective ground cable. The threaded welded studs on the door and on the cabinet side wall must be used as connecting points for the ground leads. Door hinges On the right, can be converted by user Type Door Door hinges right can be converted by user door opening angle 120° Door interlock Protection insulated turn-buckle Standard closure 3 mm double-ward key Locks Number 1 Design verification as per IEC/EN 61439 (Show features) (Hide features) Technical data for design verification Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees, calculated as per IEC 60890 Individual enclosure for wall mounting P V CO 13 Starting enclosure for wall mounting P V CO 12 Middle enclosure for wall mounting P V CO 11 Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees, calculated as per IEC 60890 Individual enclosure for wall mounting P V CO 25 Starting enclosure for wall mounting P V CO 23 Middle enclosure for wall mounting P V CO 21 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply to enclosures without lifting aids. 10.2.6 Mechanical impact IK09 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES IP66_x 10.4 Clearances and creepage distances Is the panel builder's responsibility. 10.5 Protection against electric shock < 0.1 Ω; meets the product standard's requirements. 10.6 Incorporation of switching devices and components Is the panel builder's responsibility. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength U i = 1000 V AC 10.9.3 Impulse withstand voltage Does not apply to basic enclosures as defined in EN 62208. 10.9.4 Testing of enclosures made of insulating material Does not apply to metal enclosures. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. 10.13 Mechanical function Meets the product standard's requirements. Approvals Product Standards UL 508A; CSA-C22.2 No.14; IEC/EN 60529; CE marking UL File No. E336299 UL Category Control No. NITW CSA File No. – CSA Class No. – North America Certification Request filed for CSA Conditions of Acceptability Series CS may be provided with metal sub-panel. No back mounted components are allowed between sub-panel and the back sheet metal enclosure Specially designed for North America No Suitable for Industrial Control Panels Degree of Protection IEC: IP66, indoor and outdoor; UL/CSA Types 1, 12, indoor only. Dimensions >Dimensions CAD data >Product-specific CAD data > 3D Preview Additional product information (links) AWA4300-2521 CS wall-mounted sheet steel enclosures with mounting plate >>
Categories: Control Cabinets Switch Boxes Distribution Enclosures CS Accessories - EATON - MOELLER
更多产品:
- AR25FSB2V0N610,CPC,直线导轨,直线导轨
- 74271722 Ferritkerne
- W26-8-PO
- AWG max.: 12 · AWG min.: 28 · Anschluss (Bauelemente): Federklemme · Anzahl Reihen: 1 · Farbe: Orange · Gehäuse-Material: Polyamid · Herst.-Teilenr.: 731-637/019-000 · Industrieware: Ja · Inhalt: 25 St. · Isolationsmaterial: Polyamid · Kontaktmaterial: El
- MS25089-3EWL
- SRB-301-SQ
- 42912219
- 5601SE1P5A4RV45S
- Zentrierung bis Ø 3,70 mm beidseitig mit 90° Vollspitze, darüber mit Innenzentrierung, mit geradem Schaft-Ø für die standardisierte Aufnahme in Hydrodehnspannfutter und Hochgenauigkeitsspannfutter. Durch die enge Toleranz der Schäfte wird die Spanngenauig
- 02155550
- F355J1-311
- TEN 6-4811WIN 变压器
- R433070590
- DXP-M203SM-B