EATON伊顿  CS-2520/150

EATON伊顿 CS-2520/150-产品快照

品牌:
EATON
型号:
CS-2520/150

* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.


供应商名称 电话 备注
深圳市格雷创科技有限公司 400-811-6961 微信及邮件咨询,官网:www.gchane.com
上海亦翔电气技术有限公司 021-61488548
深圳市欧捷诚科技有限公司 0755-26650315
苏州哈德控制技术有限公司
上海沪朗电气有限公司 15905696881
杭州捍特电气有限公司 021-51720278
伊顿(中国)投资有限公司 021-52000099

EATON供应商或现货商入驻,请点击>>

产品介绍

EATON伊顿 CS-2520/150

CS-2520/150 111646 EATON MOELLER Wall enclosure, +mounting plate, HxWxD 250x200x150mm

EATON - MOELLER

Wall enclosure, +mounting plate, HxWxD=250x200x150mm

Delivery programme Product range Wall-mounting housing CS Product function Wall-mounting housing with mounting plate Degree of Protection IP66 IP23 (with ventilating plates) Description Foamed polyurethane sealing throughout. Impact resistance category IK09 to EN 62262. Sheet steel mounting plate Bottom plate with foamed gasket. Single door, door stop on the right, door opening angle 120° Door hinge pins with quick change technology. Standardized locking system with sash fastener. Powder coating RAL 7035 inside and outside Material Steel plate Dimensions Width mm 200 Height mm 250 Depth mm 150 Locks Number 1 Hinges Number 2 Door profile molding Number 1 Flange plates Width x Depth mm 112 x 182 Max. F3A flanges Number - Mounting plates Height mm 220 Width mm 150 Weight kg 3.4 Information about equipment supplied Lock, 3 mm double ward key Including M6 threaded welded studs for earth conductor connections in the door Technical data General Standards IEC/EN 60529, IEC 62262, IEC/EN 62208 RoHS In accordance with Directive 2002/95/EC of the European Parliament and Council RoHS (in accordance with Directive 2002/95/EC of the European Parliament and Council) yes Climatic proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30 Ambient temperature °C -40 - +70 Degree of Protection IP66 IP23 (with ventilating plates) Installation conditions Indoor-/outdoor installation Power loss Power loss P v [W] for fully enclosed sheet steel enclosure CS without internal partitions for wall mounting. Example: max. ambient temperature 35°C; Overtemperature ΔT = 20 K; Relative humidity = 75%. Max. heat dissipation Individual enclosure for wall mounting P V W 11 Starting enclosure for wall mounting P V W 10 Middle enclosure for wall mounting P V W 9 Material characteristics Material Steel plate Surface treatment Structured powder spray polyester based paint finish Surface finish Semi-textured Colour RAL 7035, light grey Finish Gloss Material thickness mm Body mm 1.2 Mounting plate mm 2 Door mm 1 Bottom plate mm 1.5 Material properties Mechanical Impact resistance IK09 according to EN 62262 max. assembly weights Total of Weight of fitted components kg 150 Mounting plate kg 125 Door kg 25 500 kg payload, when brackets fitted in all four enclosure corners (vertically or horizontally) and the weights are symmetrically distributed within the enclosure. Description/standard features Construction Canted and seam welded, including two M6 threaded bolts for earth conductor connections inside the enclosure. Back plate 9 mm drilling dimensions for wall mounting Side plates Without apertures Top plate Without apertures Bottom plate Enclosed, foamed gasket, can be unscrewed for F3A-… flanges or for assembly by user Mounting plate, material Sheet steel, hot-galvanized Door, Engineering Including M6 threaded welded studs for earth conductor connections in the door: Information about equipment supplied Lock, 3 mm double ward key Including M6 threaded welded studs for earth conductor connections in the door  If electrical apparatus is to be installed in the door, a continuous, permanent protective ground contactor connection must be established with a protective ground cable. The threaded welded studs on the door and on the cabinet side wall must be used as connecting points for the ground leads. Door hinges On the right, can be converted by user Type Door Door hinges right can be converted by user door opening angle 120° Door interlock Protection insulated turn-buckle Standard closure 3 mm double-ward key Locks Number 1 Design verification as per IEC/EN 61439 (Show features) (Hide features) Technical data for design verification Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees, calculated as per IEC 60890 Individual enclosure for wall mounting P V CO 13 Starting enclosure for wall mounting P V CO 12 Middle enclosure for wall mounting P V CO 11 Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees, calculated as per IEC 60890 Individual enclosure for wall mounting P V CO 25 Starting enclosure for wall mounting P V CO 23 Middle enclosure for wall mounting P V CO 21 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply to enclosures without lifting aids. 10.2.6 Mechanical impact IK09 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES IP66_x 10.4 Clearances and creepage distances Is the panel builder's responsibility. 10.5 Protection against electric shock < 0.1 Ω; meets the product standard's requirements. 10.6 Incorporation of switching devices and components Is the panel builder's responsibility. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength U i = 1000 V AC 10.9.3 Impulse withstand voltage Does not apply to basic enclosures as defined in EN 62208. 10.9.4 Testing of enclosures made of insulating material Does not apply to metal enclosures. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. 10.13 Mechanical function Meets the product standard's requirements. Approvals Product Standards UL 508A; CSA-C22.2 No.14; IEC/EN 60529; CE marking UL File No. E336299 UL Category Control No. NITW CSA File No. – CSA Class No. – North America Certification Request filed for CSA Conditions of Acceptability Series CS may be provided with metal sub-panel. No back mounted components are allowed between sub-panel and the back sheet metal enclosure Specially designed for North America No Suitable for Industrial Control Panels Degree of Protection IEC: IP66, indoor and outdoor; UL/CSA Types 1, 12, indoor only. Dimensions >Dimensions CAD data >Product-specific CAD data > 3D Preview Additional product information (links) AWA4300-2521 CS wall-mounted sheet steel enclosures with mounting plate >>

Categories: Control Cabinets Switch Boxes Distribution Enclosures CS Accessories - EATON - MOELLER

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。