Siemens西门子 3RT1015-1BW42 直流接触器-产品快照
- 品牌:
- Siemens
- 型号:
- 3RT1015-1BW42
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
众业达电气(深圳)有限公司 | 0755-89314987 | irene.li@zyd.cn,13509669211 |
大连鼎宏科技有限公司 | 0411-83693111 | |
东莞市欧能自动化设备有限公司 | 18680502757 | |
福建萤光电气科技发展有限公司 | 18359060969 | |
福州福大自动化科技有限公司 | 0591-28482265 | |
广州锋力五金机电有限公司 | 020-87359185 | |
广州汇尼克机电设备有限公司 | 020-85549829 | |
广州市黄埔区科技开发总公司 | ||
海格曼商贸(上海)有限公司 | 4008215282 | |
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
深圳市行健自动化股份有限公司 | 0755-86336499 | |
深圳市昊普锐科技有限公司 | 0755-82127363 | |
深圳市朗助机电有限公司 | 0755-83975718 | |
深圳市曼伯特实业发展有限公司 | 0755-82032366 | |
苏州工品汇信息科技有限公司 | 4000496999 |
产品介绍
Siemens西门子 3RT1015-1BW42 直流接触器
3RT1015-1BW42 SIEMENS CONTACTOR, AC-3 3 KW/400 V, 1 NC, DC 48 V, 3-POLE, SIZE S00, SCREW CONNECTION
SIEMENS
CONTACTOR, AC-3 3 KW/400 V, 1 NC, DC 48 V, 3-POLE, SIZE S00, SCREW CONNECTION
product brand name SIRIUS Product designation power contactor General technical data: Size of contactor S00 Degree of pollution 3 Protection class IP ● on the front IP20 ● of the terminal IP20 Mechanical service life (switching cycles) ● of contactor typical 30 000 000 ● of the contactor with added electronics-compatible auxiliary switch block typical 5 000 000 ● of the contactor with added auxiliary switch block typical 10 000 000 Ambient conditions: Installation altitude at height above sea level maximum 2 000 m Ambient temperature ● during operation -25 ... +60 °C Main circuit: Number of NO contacts for main contacts 3 Number of NC contacts for main contacts 0 Operating current ● at AC-1 at 400 V — at ambient temperature 40 °C rated value 18 A ● at AC-1 — up to 690 V at ambient temperature 40 °C rated value 18 A — up to 690 V at ambient temperature 60 °C rated value 16 A ● at AC-3 — at 400 V rated value 7 A Operating current ● at 1 current path at DC-1 — at 24 V rated value 15 A — at 110 V rated value 1.5 A ● with 2 current paths in series at DC-1 — at 24 V rated value 15 A — at 110 V rated value 8.4 A ● with 3 current paths in series at DC-1 — at 24 V rated value 15 A — at 110 V rated value 15 A Operating current ● at 1 current path at DC-3 at DC-5 — at 24 V rated value 15 A — at 110 V rated value 0.1 A ● with 2 current paths in series at DC-3 at DC-5 — at 110 V rated value 0.25 A — at 24 V rated value 15 A ● with 3 current paths in series at DC-3 at DC-5 — at 110 V rated value 15 A — at 24 V rated value 15 A Operating power ● at AC-1 — at 400 V rated value 11 kW ● at AC-2 at 400 V rated value 3 kW ● at AC-3 — at 400 V rated value 3 kW — at 500 V rated value 3.5 kW — at 690 V rated value 4 kW Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor 0.42 W Control circuit/ Control: Type of voltage of the control supply voltage DC Control supply voltage at DC ● rated value 48 V Operating range factor control supply voltage rated value of magnet coil at DC 0.85 ... 1.1 Closing power of magnet coil at DC 3.3 W Holding power of magnet coil at DC 3.3 W Auxiliary circuit: Number of NC contacts ● for auxiliary contacts — instantaneous contact 1 Number of NO contacts ● for auxiliary contacts — instantaneous contact 0 Operating current at AC-12 maximum 10 A Operating current at AC-15 ● at 230 V rated value 6 A ● at 400 V rated value 3 A Operating current at DC-12 ● at 60 V rated value 6 A ● at 110 V rated value 3 A ● at 220 V rated value 1 A Operating current at DC-13 ● at 24 V rated value 10 A ● at 60 V rated value 2 A ● at 110 V rated value 1 A ● at 220 V rated value 0.3 A Contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) Short-circuit protection Design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required fuse gL/gG: 35 A — with type of assignment 2 required fuse gL/gG: 20 A ● for short-circuit protection of the auxiliary switch required fuse gL/gG: 10 A Installation/ mounting/ dimensions: Mounting type screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 ● Side-by-side mounting Yes Height 57.5 mm Width 45 mm Depth 72 mm Required spacing ● for grounded parts — at the side 6 mm Connections/Terminals: Type of electrical connection ● for main current circuit screw-type terminals ● for auxiliary and control current circuit screw-type terminals Type of connectable conductor cross-sections ● for main contacts — solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²) — single or multi-stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²) — finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) ● at AWG conductors for main contacts 2x (20 ... 16), 2x (18 ... 14), 1x 12 Type of connectable conductor cross-sections ● for auxiliary contacts — solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²) — finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) ● at AWG conductors for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14), 1x 12
Categories: Contactors for switching motors