EATON伊顿  DILA-22(110VDC) 直流接触器

EATON伊顿 DILA-22(110VDC) 直流接触器-产品快照

品牌:
EATON
型号:
DILA-22(110VDC)

* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.


供应商名称 电话 备注
深圳市格雷创科技有限公司 400-811-6961 微信及邮件咨询,官网:www.gchane.com
上海亦翔电气技术有限公司 021-61488548
深圳市欧捷诚科技有限公司 0755-26650315
苏州哈德控制技术有限公司
上海沪朗电气有限公司 15905696881
杭州捍特电气有限公司 021-51720278
伊顿(中国)投资有限公司 021-52000099

EATON供应商或现货商入驻,请点击>>

产品介绍

EATON伊顿 DILA-22(110VDC) 直流接触器

DILA-22(110VDC) 276417 EATON MOELLER Contactor relay, 2N/O+2N/C, DC current

EATON - MOELLER

Contactor relay, 2N/O+2N/C, DC current

Delivery programme Product range DILA relays Application Contactor relays Description Basic devices with positive operation contacts Connection technique Screw terminals Rated operational current AC-15 220 V 230 V 240 V I e A 4 380 V 400 V 415 V I e A 4 Contacts N/O = Normally open 2 N/O N/C = Normally closed 2 NC Contact sequence Code number and version of combination Distinctive number 22D Can be combined with auxiliary contact module DILA-XHI(V)… Actuating voltage 110 V DC Voltage AC/DC DC operation Suppressor circuit built-in Instructions Contact numbers to EN 50011 Coil terminal markings to EN 50005 built-in suppressor circuit' Technical data General Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated Operations x 10 6 20 DC operated Operations x 10 6 20 Maximum operating frequency Ops./h Maximum operating frequency Operations/h 9000 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open °C -25 - +60 Enclosed °C - 25 - 40 Ambient temperature, storage °C - 40 - 80 Mounting position Mounting position Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock, 10 ms Basic unit with auxiliary contact module g N/O contact g 7 N/C contact g 5 Degree of Protection IP20 Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Weight AC operated kg 0.23 DC operated kg 0.28 Terminal capacities mm 2 Screw terminals Solid mm 2 1 x (0,75 - 4) 2 x (0,75 - 2,5) Flexible with ferrule mm 2 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) Solid or stranded AWG 18 - 14 Terminal screw M3.5 Pozidriv screwdriver Size 2 Standard screwdriver mm 0.8 x 5.5 1 x 6 Max. tightening torque Nm 1.2 Spring-loaded terminals Solid mm 2 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) Flexible with or without ferrule DIN 46228 mm 2 1 x (0,75 - 1.5) 2 x (0,75 - 1.5) Solid or stranded AWG 18 - 14 Standard screwdriver mm 0.6 x 3.5 Contacts Positive operating contacts to ZH 1/457, including auxiliary contact module Yes Rated impulse withstand voltage U imp V AC 6000 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V AC 690 Rated operational voltage U e V AC 690 Rated operational current A Conventional free air thermal current, 3 pole, 50 - 60 Hz Open Conv. thermal current I th A 16 AC-15 220 V 230 V 240 V I e A 4 380 V 400 V 415 V I e A 4 500 V I e A 1.5 DC current DC-13 L/R - 15 ms Contacts in series: A 1 24 V A 10 1 60 V A 6 2 60 V A 10 1 110 V A 3 3 110 V A 6 1 220 V A 1 3 220 V A 5 DC L/R50 ms Contacts in series: A 3 24 V A 4 3 60 V A 4 3 110 V A 2 3 220 V A 1 Conv. thermal current I th A 16 Safe isolation to EN 61140 between coil and auxiliary contacts V AC 400 between the auxiliary contacts V AC 400 Control circuit reliability Failure rate λ <10 -8 , < one failure at 100 million operations (at U e = 24 V DC, U min = 17 V, I min = 5.4 mA) Short-circuit rating without welding Maximum overcurrent protective device 220 V 230 V 240 V PKZM0 4 380 V 400 V 415 V PKZM0 4 Short-circuit protection maximum fuse 500 V A gG/gL 10 Current heat loss at I th AC operated W 0.3 DC operated W 0.3 Magnet systems Voltage tolerance x U c AC operated x U c Pick-up x U c 0.8 - 1.1 DC operated x U c Pick-up x U c 0.8 - 1.1 at 24 V: without auxiliary contact component (40 °C) Pick-up x U c 0.7 - 1.3 Power consumption 50 Hz Pick-up VA 24 50 Hz Sealing VA 3.4 50 Hz Sealing W 1.2 60 Hz Pick-up VA 30 60 Hz Sealing VA 4.4 60 Hz Sealing W 1.4 50/60 Hz Pick-up VA 27 25 50/60 Hz Sealing VA 4.2 3.3 50/60 Hz Sealing W 1.4 1.2 DC operated Pull-in = sealing W 3 duty factor % DF 100 Switching times at 100 % U c (approximate values) AC operated closing delay ms 15 - 21 AC operated N/O contact opening delay ms 9 - 18 DC operated closing delay ms Switching times, DC operated, max. closing delay ms 31 DC operated N/O contact opening delay ms Switching times, DC actuated make contact Opening delay, max. ms 12 Notes Notes Making and breaking conditions to DC-13, time constant as stated Smoothed DC, three-phase bridge rectifiers or smoothed double-wave rectification Design verification as per IEC/EN 61439 (Show features) (Hide features) Technical data for design verification Rated operational current for specified heat dissipation I n A 15.5 Heat dissipation per pole, current-dependent P vid W 1 Equipment heat dissipation, current-dependent P vid W 0 Static heat dissipation, non-current-dependent P vs W 2.6 Heat dissipation capacity P diss W 0 Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 60 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 (Show features) (Hide features) Low-voltage industrial components (EG000017) / Contactor relay (EC000196) Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Contactor relay ( [email protected] [AAB716011]) Rated control supply voltage Us at AC 50HZ V 0 - 0 Rated control supply voltage Us at AC 60HZ V 0 - 0 Rated control supply voltage Us at DC V 110 - 110 Voltage type for actuating DC Rated operation current Ie , 400 V A 4 Connection type auxiliary circuit Screw connection Mounting method DIN-rail/screw Interface No Number of auxiliary contacts as normally closed contact 2 Number of auxiliary contacts as normally open contact 2 Number of auxiliary contacts as normally closed contact, delayed switching 0 Number of auxiliary contacts as normally open contact, leading 0 With LED indication No Number of auxiliary contacts as change-over contact 0 Manual operation possible No Approvals Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 012528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Specially designed for North America No Characteristics 1: Suppressor 2: Auxiliary contact module Component lifespan (operations) Ie = Rated operational current Component lifespan (operations) Ie = Rated operational current

Categories: Contactor Relays Contactor Relays DILA - EATON - MOELLER

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。