EATON伊顿 S811+N66P3S 软启动器-产品快照
- 品牌:
- EATON
- 型号:
- S811+N66P3S
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 S811+N66P3S 软启动器
S811+N66P3S 168979 EATON MOELLER Soft starter, 3p, 66A, Ue 200-600VAC
EATON - MOELLER
Soft starter, 3p, 66A, Ue= 200-600VAC
Delivery programme Description With internal bypass contacts Function Soft starter for three-phase loads, with control unit and pump algorithm Mains supply voltage (50/60 Hz) U LN V AC 200 - 600 Supply voltage U s 24 V DC Control voltage U C 24 V DC Assigned motor rating (Standard connection, In-Line) at 400 V, 50 Hz P kW 30 at 460 V, 60 Hz P HP 50 Rated operational current AC-53 I e A 66 AC-53, In-Delta I e A 114 Startup class CLASS 10 (star-delta replacement) CLASS 20 (heavy starting duty 3 x I e for 45 s) CLASS 30 (6 x I e for 30 s) Rated operational voltage U e 200 V 230 V 400 V 480 V 600 V Connection to SmartWire-DT no Frame size N Technical data General Standards IEC/EN 60947-4-2 UL 508 CSA22.2-14-1995 GB14048 Approvals CE Approvals UL CSA C-Tick CCC Climatic proofing Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-10 Ambient temperature Operation ϑ °C -30 - +50 Storage ϑ °C -50 - +70 Altitude m 0 - 2000 m, above that each 100 m 0.5% Derating Mounting position As required Degree of protection Degree of Protection IP20 (terminals IP00) Integrated Protection type IP40 can be achieved on all sides with covers SS-IP20-N. Protection against direct contact Finger- and back-of-hand proof Overvoltage category/pollution degree II/3 Shock resistance 15 g Radio interference level (IEC/EN 55011) A Static heat dissipation, non-current-dependent P vs W 25 Weight kg 2.6 Main conducting paths Rated operating voltage U e V AC 200 - 600 Supply frequency f LN Hz 50/60 Rated operational current I e A AC-53, In-Delta I e A 114 AC-53 I e A 66 Assigned motor rating (Standard connection, In-Line) at 230 V, 50 Hz P kW 18.5 at 400 V, 50 Hz P kW 30 at 500 V, 50 Hz P kW 45 at 200 V, 60 Hz P HP 20 at 230 V, 60 Hz P HP 20 at 460 V, 60 Hz P HP 50 at 600 V, 60 Hz P HP 60 Assigned motor rating (delta connection) at 230 V, 50 Hz P kW 30 at 400 V, 50 Hz P kW 55 at 500 V, 50 Hz P kW 75 at 230 V, 60 Hz HP 40 at 480 V, 60 Hz HP 75 at 600 V, 60 Hz P HP 100 Overload cycle to IEC/EN 60947-4-2 AC-53a 66 A: AC-53a: 4.0 - 32: 99 - 3 Internal bypass contacts Technical data for design verification Rated operational current for specified heat dissipation I n A 66 Heat dissipation per pole, current-dependent P vid W 0 Equipment heat dissipation, current-dependent P vid W 25 Static heat dissipation, non-current-dependent P vs W 25 Heat dissipation capacity P diss W 0 Operating ambient temperature min. °C -30 Operating ambient temperature max. °C 50 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 (Show features) (Hide features) Low-voltage industrial components (EG000017) / Soft starter (EC000640) Electric engineering, automation, process control engineering / Low-voltage switch technology / Load breakout, motor breakout / Semiconductor motor controller or soft starter ( [email protected] [ACO300008]) Rated operation current Ie at 40 °C Tu A 66 Rated operating voltage Ue V 200 - 600 Rated power three-phase motor, inline, at 230 V kW 18.5 Rated power three-phase motor, inline, at 400 V kW 30 Rated power three-phase motor, inside delta, at 230 V kW 30 Rated power three-phase motor, inside delta, at 400 V kW 55 Internal bypass Yes With display Yes Torque control No Rated surrounding temperature without derating °C 50 Rated control supply voltage Us at AC 50HZ V 0 - 0 Rated control supply voltage Us at AC 60HZ V 0 - 0 Rated control supply voltage Us at DC V 24 - 24 Voltage type for actuating DC Integrated motor overload protection Yes Approvals Product Standards IEC/EN 60947-4-2; UL 508; CSA C22.2 No. 14; CE marking UL File No. E202571 UL Category Control No. NMFT CSA File No. LR 353 CSA Class No. 3211-06, 2411-01 North America Certification UL listed, CSA certified Suitable for Branch Circuits, not as BCPD Max. Voltage Rating 600 Vac Degree of Protection IP20 with kit Dimensions >
Categories: Softstarters Soft Starters Motor S8 Soft starters - EATON - MOELLER