ABB BC7-30-01-P-2,4 直流接触器-产品快照
- 品牌:
- ABB
- 型号:
- BC7-30-01-P-2,4
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
众业达电气(深圳)有限公司 | 0755-89314987 | irene.li@zyd.cn,13509669211 |
上海锝秉工控设备有限公司 | 021-39520660 | 工业自动化控制 |
南京蒂尔斯科技发展有限公司 | 025-84572847 | |
佛山市路加机电贸易有限公司 | ||
杭州和枫电气有限公司 | ||
上海乐利自动化科技有限公司 | ||
成都立大电气有限公司 | ||
福建富通达电气技术有限公司 | ||
广州昊永机电设备有限公司 | 020-82030832 | |
高捷联电源环保科技(苏州)有限公司 | 0512-62622223 | |
中山市凯昌机电设备有限公司 | ||
广州申控电气技术有限公司 | ||
成都乾诚自动化设备有限公司 | 028-66017989 | |
西安合纵电气自动化有限公司 | 029-8524 5169 | |
浙江中研电气有限公司 |
产品介绍
ABB BC7-30-01-P-2,4 直流接触器
BC7-30-01-P-2,4 GJL1313009R5011 ABB BC7-30-01-P-2.4-51 Mini Contactor 17-32VDC, 2.4W
ABB
BC7-30-01-P-2.4-51 Mini Contactor 17-32VDC, 2.4W
The BC7-30-01-P mini contactor is a compact 3 pole contactor with 1 auxiliary contact and soldering pins. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A / 690 V (AC-1) or switching of control signals. Due to the low coil consumption, this device can be directly controlled by a PLC. Further features are the noiseless and hum-free coil and a switch position indication. Ordering EAN: 4013614192258 Minimum Order Quantity: 1 piece Customs Tariff Number: 85365080 Dimensions Product Net Width: 47.5 mm Product Net Height: 45.5 mm Product Net Depth: 51.5 mm Product Net Weight: 0.17 kg Container Information Package Level 1 Units: 10 piece Package Level 1 Width: 108 mm Package Level 1 Height: 69 mm Package Level 1 Length: 247 mm Package Level 1 Gross Weight: 1.775 kg Package Level 1 EAN: 4013614418761 Technical Number of Poles: 4 Mini Contactor Type: Interface Mini Contactor Rated Operational Voltage: Auxiliary Circuit 12 ... 240 V DC Auxiliary Circuit 12 ... 500 V AC/DC Main Circuit 12 ... 690 V AC/DC Main Circuit 690 V AC Rated Frequency (f): Control Circuit DC Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC Rated Impulse Withstand Voltage (U imp ): Auxiliary Circuit 6 kV Main Circuit 6 kV Rated Insulation Voltage (U i ): 690 V acc. to UL/CSA 600 V Number of Main Contacts NC: 0 Number of Main Contacts NO: 3 Rated Operational Current AC-1 (I e ): (220 / 240 V) 40 °C 12 A (220 / 240 V) 55 °C 12 A (380 / 440 V) 40 °C 12 A (380 / 440 V) 55 °C 12 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A Rated Operational Power AC-3 (P e ): (220 / 230 / 240 V) 3 kW (400 V) 5.5 kW (400 V) Three Phase 5.5 kW (440 V) 5.5 kW (500 V) 5.5 kW (690 V) 3 kW Rated Short-time Withstand Current (I cw ): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A Number of Auxiliary Contacts NC: 1 Number of Auxiliary Contacts NO: 0 Rated Operational Current AC-15 (I e ): (120 V) 4 A (220 / 240 V) 4 A (24 V) 4 A (380 / 400 V) 3 A (500 V) 2 A Rated Operational Current DC-13 (I e ): (110 V) 0.7 A (220 / 240 V) 0.4 A (24 V) 2.5 A Conventional Free-air Thermal Current (I th ): Main Circuit 12 A Rated Control Circuit Voltage (U c ): 17 ... 32 V DC Coil Operating Limits: (acc. to IEC 60947-4-1) for DC supply Uc Min. ... Uc Max. (at θ ≤ 55 °C) Degree of Protection: Auxiliary Circuit Terminals IP20 Control Circuit Terminals IP20 Main Circuit Terminals IP20 Mechanical Durability: 10000000 cycle Minimum Switching Capacity: 17 V 5 mA Maximum Electrical Switching Frequency: AC-1 300 cycles per hour AC-15 600 cycles per hour AC-3 600 cycles per hour DC-1 600 cycles per hour DC-13 600 cycles per hour DC-3 600 cycles per hour Mounting on DIN Rail: TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 Power Loss: at Rated Operating Conditions per Pole 2 W Standards: IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 Remarks: No CA6 or CAF6 mountable Environmental Ambient Air Temperature: Operation -20 ... +55 °C Storage -40 ... +80 °C Maximum Operating Altitude Permissible: 2000 m Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 15g Resistance to Vibrations acc. to IEC 60068-2-6: 5g / 5 ... 150 Hz RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment Technical UL/CSA Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC Full Load Amps Motor Use: (240 V AC) Single Phase 10 A (440 ... 480 V AC) Three Phase 7.6 A Horsepower Rating UL/CSA: (208 V AC) Three Phase 3 Hp (220 ... 240 V AC) Single Phase 1.5 Hp (220 ... 240 V AC) Three Phase 3 Hp (440 ... 480 V AC) Three Phase 5 Hp (550 ... 600 V AC) Three Phase 5 Hp General Use Rating UL/CSA: (600 V AC) 16 A Certificates and Declarations (Document Number) BV Certificate: 1SAA938000-0203 CB Certificate: 1SAA938000-2002 CCC Certificate: 1SAA938001-3804 cUL Certificate: 1SAA938003-1701 Declaration of Conformity - CE: 1SAD938509-0001 DNV Certificate: 1SAA938000-0305 EAC Certificate: 1SAA920000-2702 GL Certificate: 1SAA938000-0403 LR Certificate: 1SAA938000-0503 RMRS Certificate: 1SAA938000-0703 RoHS Information: 1SAA938003-4403 UL Certificate: 1SAA938000-1604 Classifications Object Classification Code: Q eClass: 7.0 27371003 ETIM 4: EC000066 - Magnet contactor, AC-switching ETIM 5: EC000066 - Magnet contactor, AC-switching UNSPSC: 39121529
Categories: Contactor Relays Contactors and overload relays Minicontactors B6-B7