产品介绍
EATON伊顿 IZMX40B3-U10F 断路器
IZMX40B3-U10F 149678 EATON MOELLER Circuit-breaker, 3p, 1000 A, fixed
EATON - MOELLER
Circuit-breaker, 3p, 1000 A, fixed
Delivery programme Product range Air circuit-breakers/switch-disconnectors Product range Open circuit-breakers Current Range Up to 4000 A Protective function Universal protection Installation type Fixed Construction size IZMX40 Release system Electronic release Standard/Approval IEC Number of poles 3 pole Degree of Protection IP20, IP55 with protective cover, IP41 door sealing frame suitable for zone selectivity suitable for communication integrated system monitor and 4-character display optionally fittable by user with comprehensive accessories Rated current = rated uninterrupted current I n = I u A 1000 Breaking capacity Icu = Ics to 440 V 50/60 Hz I cu kA 66 Breaking capacity Ics to 440 V 50/60 Hz I cs kA 66 Overload release, min. I r A 500 Overload release, max. I r A 1000 Non-delayed General Standards IEC/EN 60947 Ambient temperature Storage ϑ °C -25 - +70 (device with LCD-display -20 - +70) Operating (open) °C -25 - +70 (device with LCD-display -20 - +70) Mounting position Technical data for design verification Rated operational current for specified heat dissipation I n A 1000 Equipment heat dissipation, current-dependent P vid W 55 Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 70 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228) Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ( [email protected] [AJZ716010]) Rated permanent current Iu A 1000 Rated voltage V 690 - 690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz kA 66 Overload release current setting A 500 - 1000 Adjustment range short-term delayed short-circuit release A 2000 - 10000 Adjustment range undelayed short-circuit release A 2000 - 12000 Integrated earth fault protection No Type of electrical connection of main circuit Rail connection Device construction Built-in device fixed built-in technique Suitable for DIN rail (top hat rail) mounting No DIN rail (top hat rail) mounting optional No Number of auxiliary contacts as normally closed contact 0 Number of auxiliary contacts as normally open contact 0 Number of auxiliary contacts as change-over contact 2 Switched-off indicator available Yes With under voltage release No Number of poles 3 Position of connection for main current circuit Back side Type of control element Push button Complete device with protection unit Yes Motor drive integrated No Motor drive optional Yes Degree of protection (IP) IP20
Categories: Circuit Breakers Electrical Power