供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 OPTC8 模块
OPTC8 125072 EATON MOELLER Field bus module Modbus RS485 with socket SUB-D 9-pole for variable frequency dri..
EATON - MOELLER
Field bus module Modbus RS485 with socket SUB-D 9-pole for variable frequency drive SVX and SPX
Delivery programme Part group reference (e.g. DIL) SVX SPX Bus protocol Modbus RS485 Description The field bus module is plugged into the variable-frequency drive. For use with SVX, SPX Connection technique SUB-D 9 pole, socket Design verification as per IEC/EN 61439 (Show features) (Hide features) IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Approvals Product Standards UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking UL File No. E134360 UL Category Control No. NMMS, NMMS2, NMMS7. NMMS8 CSA File No. UL report applies to both US and Canada North America Certification UL listed, certified by UL for use in Canada Specially designed for North America No Suitable for Branch circuits Additional product information (links) IL04012011Z Instructions for Expansion cards for frequency inverter 9000X >>
Categories: Variable Adjustable Frequency Speed Drives Inverters Vfd Vvvf Voltage Frequency inverters SVX-SPX - EATON - MOELLER