供应商名称 | 电话 | 备注 |
---|---|---|
北京市京浙电子技术有限公司 | 010-82665209 | |
东莞市科威自动化设备有限公司 | 4006699083 | |
东莞市欧能自动化设备有限公司 | 18680502757 | |
东莞市中昊自动化科技有限公司 | 0769-22882481 | 传感器解决方案 |
东莞运通工业器材有限公司 | 0769-28056288 | |
福州倍德福工业自动化设备有限公司 | 0591-83500620 | |
福州福大自动化科技有限公司 | 0591-28482265 | |
广州科韵商贸发展有限公司 | 020-87508653 | |
广州市振欣自动化系统有限公司 | 020-85267788 | |
买道传感科技(上海)有限公司 | 021-51872140 | |
上海行之达电子有限公司 | 021-66988928 | |
上海欧龙翰邦自动化系统有限公司 | 021-32515208 | |
深圳市华光行电工器材有限公司 | ||
深圳市明琪宏科技有限公司 | 0755-82873757 | |
苏州工品汇信息科技有限公司 | 4000496999 |
产品介绍
OMRON欧姆龙 ZS-XC8A 张力传感器
ZS-XC8A 180558 OMRON Advanced Sensors, Extension Cable 8 meters
OMRON
Advanced Sensors, Extension Cable 8 meters
Ordering information Sensors ZS-HL-series sensor heads Optical system Sensing distance Beam shape Beam diameter Resolution Order code Regular reflective models 20±1 mm Line beam 1.0 mm × 20 µm 0.25 µm ZS-HLDS2T 25±2 mm 2.2 mm × 45 µm 0.6 µm ZS-HLDS2VT Diffuse reflective models 50±5 mm 1.0 mm × 30 µm 0.25 µm ZS-HLDS5T 100±20 mm 3.5 mm × 60 µm 1 µm ZS-HLDS10 600±350 mm 16 mm × 0.3 mm 8 µm ZS-HLDS60 1500±500 mm 40 mm × 1.5 mm 500 µm ZS-HLDS150 ZS-HL-series sensor heads (for nozzle gaps) also compatible with ZS-L controller Optical system Sensing distance Beam shape Beam diameter Resolution Order code Regular reflective models 10±0.5 mm Line beam 900x25 µm 0.25 µm ZS-LD10GT 15±0.75 mm ZS-LD15GT ZS-L-series sensor heads Optical system Sensing distance Beam shape Beam diameter Resolution Order code Regular reflective models 20±1 mm Line beam 900 × 25 µm 0.25 µm ZS-LD20T Spot beam 25 µm dia. ZS-LD20ST 40±2.5 mm Line beam 2000 × 35 µm ZS-LD40T Diffuse reflective models 50±5 mm Line beam 900 × 60 µm 0.8 µm ZS-LD50 Spot beam 50 µm dia. ZS-LD50S 80±15 mm Line beam 900 × 60 µm 2 µm ZS-LD80 130±15 mm Line beam 600 × 70 µm 3 µm ZS-LD130 200 ±50 mm Line beam 900 × 100 µm 5 µm ZS-LD200 350 ±135 mm Spot beam 240 µm dia. 20 µm ZS-LD350S ZS-HL-series sensor controllers Supply voltage Control outputs Order code 24 VDC NPN outputs ZS-HLDC11 PNP outputs ZS-HLDC41 ZS-HLDC41A (incl. USB cable + Smart monitor) Multi-controllers Supply voltage Control outputs Order code 24 VDC NPN outputs ZS-MDC11 PNP outputs ZS-MDC41 Data storage units Supply voltage Control outputs Order code 24 VDC NPN outputs ZS-DSU11 PNP outputs ZS-DSU41 Accessories (sold separately) Controller link Item Order code Controller link ZS-XCN Panel mount adapter Model Order code For 1st controller ZS-XPM1 For expansion (from 2nd controller on) ZS-XPM2 Cables for connecting to a Personal Computer Type Quantity Order code RS-232C 1 ZS-XRS2 USB 1 ZS-XUSB2 Extension cables for sensor heads Cable length Quantity Order code 1 m 1 ZS-XC1A 4 m 1 ZS-XC4A 5 m 1 ZS-XC5B , 8 m 1 ZS-XC8A 10 m 1 ZS-XC10B Logging software Item Order code Smart monitor zero professional ZS-SW11E Memory card Model Order code 64 MB F160-N64S(S) 128 MB QM300-N128S 256 MB F160-N256S Safety precautions for using laser equipment Specifications Sensor heads ZS-HL-series sensor heads Item ZS-HLDS2T ZS-HLDS2VT ZS-HLDS5T ZS-HLDS10 ZS-HLDS60 ZS-HLDS150 Applicable controllers ZS-HLDC series Optical system Regular reflection Diffuse reflection Regular reflection Regular reflection Diffuse reflection Regular reflection Diffuse reflection Diffuse reflection Diffuse reflection Measuring center distance 20 mm 5.2 mm 25 mm 44 mm 50 mm 94 mm 100 mm 600 mm 1,500 mm Measuring range ±1 mm ±1 mm ±2 mm ±4 mm ±5 mm ±16 mm ±20 mm ±350 mm ±500 mm Light source Visible semiconductor laser (wavelength: 650 nm, 1 mW max., JIS Clas Visible semiconductor laser (wavelength 658 nm, 1 mW max., Class 2) Beam shape Line beam Beam diameter 1.0 mmx20 µm 2.2 mmx45 µm 1.0 mmx30 µm 3.5 mmx60 µm 0.3 mmx16 mm 1.5 mmx40 mm Linearity ±0.05% F.S. ±0.2 %F.S. ±0.1% F.S. ±0.07 %F.S. (250 mm to 750 mm) ±0.1% F.S. (750 mm to 950 mm) ±0.2 %F.S. Resolution 0.25 µm (No. of samples to average: 256) 0.5 µm (No. of samples to average: 128) 0.25 µm (No. of samples to average: 512) 1 µm (No. of samples to average: 64) 8 µm (average 64) (at 250 mm) 40 µm (average 64) (at 600 mm) 500 µm (average 64) Temperature characteristic 0.01% F.S./°C 0.1% F.S./°C 0.01% F.S./°C Sampling cycle 110 µs (high-speed mode), 500 µs (standard mode), 2.2 ms (high-precision mode), 4.4 ms (high-sensitivity mode) Indicators NEAR indicator Lits near the measurement center, and nearer than the measurement center distance inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. FAR indicator Lits near the measurement center, and further than the measurement center distance inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. Operating ambient illumination Illumination on received light surface 3,000 lx or less (incandescent light) Illumination on received light surface 1,000 lx or less (incandescent light) Illumination on received light surface 500 lx or less (incandescent light) Ambient temperature Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation) Ambient humidity Operating and storage: 35% to 85% (with no condensation) Degree of protection IP64 IP67 Cable length 0.5 m: IP66, cable length 2 m: IP67 IP66 (IEC60529) Vibration resistance (destructive) 10 to 150 Hz, 0.7 mm double amplitude, 80 min each in X, Y, and Z directions Shock resistance (destructive) 150 m/s² 3 times each in six directions (up/down, left/right, forward/backward) Materials Case: aluminum die-cast, front cover: glass Cable length 0.5 m, 2 m 2 m 0.5 m, 2 m Weight Approx. 350 g Approx. 600 g Approx. 800 g *1 Defined as 1/e² (13.5%) of the center optical intensity in the measurement center distance. The beam diameter is sometimes influenced by the ambient conditions of the workpiece such as leaked light from the main beam. *2 This is the error on the measured value with respect to an ideal straight line. Linear curve may change according to the workpiece. The following lists the workpieces Model Diffusive reflection Mirror reflection ZS-HLDS2T SUS block Glass ZS-HLDS5T/HLDS10 White alumina ceramic Glass ZS-HLDS60/HLDS150 White alumina ceramic - ZS-HLDS2VT - Glass *3 This is the “peak-to-peak” displacement conversion value of the displacement output in the measurement center distance when high-resolution mode and the average number in the table are set (For ZS-HLDS60, the maximum resolution at 250 mm is also included). The following lists the workpieces. Model Diffusive reflection Mirror reflection ZS-HLDS2T SUS block Glass ZS-HLDS5T White alumina ceramic Glass ZS-HLDS10 White alumina ceramic ZS-HLDS60/HLDS150 White alumina ceramic - ZS-HLDS2VT - Glass *4 Value obtained when the sensor part and object part are fixed with an aluminum jig. ZS-L-series sensor heads Item ZS-LD20T ZS-LD20ST ZS-LD40T ZS-LD10GT ZS-LD15GT Applicable controllers ZS-HLDC/LDC series Optical system Regular reflection Diffuse reflection Regular reflection Diffuse reflection Regular reflection Diffuse reflection Regular reflection Measuring center distance 20 mm 6.3 mm 20 mm 6.3 mm 40 mm 30 mm 10 mm 15 mm Measuring range ±1 mm ±1 mm ±1 mm ±1 mm ±2.5 mm ±2 mm ±0.5 mm ±0.75 mm Light source Visible semiconductor laser (wavelength: 650 nm, 1 mW max., JIS Class 2) Beam shape Line beam Spot beam Line beam Beam diameter 900 x 25 µm 25 µm dia. 2,000 x 35 µm Approx. 25 x 900 µm Linearity ±0.1%F.S Resolution 0.25 µm 0.25 µm 0.4 µm 0.25 µm 0.25 µm Temperature characteristic 0.04% FS/°C 0.04% FS/°C 0.02% FS/°C 0.04% FS/°C Sampling cycle 110 µs (high-speed mode), 500 µs (standard mode), 2.2 ms (high-precision mode), 4.4 ms (high-sensitivity mode) Indicators NEAR indicator Lights near the measuring center distance, and nearer than the measuring center distance inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. FAR indicator Lights near the measuring center distance, and further than the measuring center distance inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. Operating ambient illumination Illumination on received light surface: 3,000 lx or less (incandescent light) Ambient temperature Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation) Ambient humidity Operating and storage: 35% to 85% (with no condensation) Degree of protection Cable length 0.5 m: IP66, cable length 2 m: IP67 IP40 Materials Case: Aluminum die-cast, front cover: Glass Cable length 0.5 m, 2 m Weight Approx. 350 g Approx. 400 g Accessories Laser labels (1 each for JIS/EN, 3 for FDA), ferrite cores (2), insure Locks (2), instruction sheet Laser safety labels (1 each for JIS/EN),ferrite cores (2), insure locks (2) ZS-L-series sensor heads Item ZS-LD50 ZS-LD50S ZS-LD80 ZS-LD130 ZS-LD200 ZS-LD350S Applicable controllers ZS-HLDC/LDC series Optical system (reflection) Diffuse Regular Diffuse Regular Diffuse Regular Diffuse Regular Diffuse Regular Diffuse Measuring center distance 50 mm 47 mm 50 mm 47 mm 80 mm 78 mm 130 mm 130 mm 200 mm 200 mm 350 mm Measuring range ±5 mm ±4 mm ±5 mm ±4 mm ±15 mm ±14 mm ±15 mm ±12 mm ±50 mm ±48 mm ±135 mm Light source Visible semiconductor laser (wavelength: 650 nm, 1 mW max., JIS Class 2) Beam shape Line beam Spot beam Line beam Line beam Line beam Spot beam Beam diameter 900 x 60 µm 50 µm dia. 900 x 60 µm 600 x 70 µm 900 x 100 µm 240 µm dia. Linearity ±0.1%F.S. ±0.25%F.S. ±0.1%F.S. ±0.25%F.S. ±0.04%F.S. Resolution 0.8 µm 0.8 µm 2 µm 3 µm 5 µm 20 µm Temperature characteristic 0.02% FS/°C 0.02% FS/°C 0.01% FS/°C 0.02% FS/°C 0.02% FS/°C 0.04% FS/°C Sampling cycle 110 µs (high-speed mode), 500 µs (standard mode), 2.2 ms (high-precision mode), 4.4 ms (high-sensitivity mode) Indicators NEAR indicator Lights near the measuring center distance, and nearer than the measuring center distance inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. FAR indicator Lights near the measuring center distance, and further than the measuring center distance inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient. Operating ambient illumination Illumination on received light surface: 3,000 lx or less (incandescent light) Illumination on received light surface: 2,000 lx or less (incandescent light) Illumination on received light surface: 3,000 lx or less (incandescent light) Ambient temperature Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation) Ambient humidity Operating and storage: 35% to 85% (with no condensation) Degree of protection Cable length 0.5 m: IP66, cable length 2 m: IP67 Materials Case: Aluminum die-cast, front cover: Glass Cable length 0.5 m, 2 m Weight Approx. 350 g Accessories Laser labels (1 each for JIS/EN, 3 for FDA), ferrite cores (2), insure Locks (2), instruction sheet Sensor controllers ZS-HL-series sensor controllers Item ZS-HLDC11 ZS-HLDC41 NPN/PNP NPN PNP No. of samples to average 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096 Number of mounted sensors 1 per sensor controller External interface Connection method Serial I/O: connector, other: pre-wired (standard cable length: 2 m) Serial I/O USB 2.0 1 port, full speed (12 Mbps max.), MINI-B RS-232C 1 port, 115,200 bps. max. Output Judgement output HIGH/PASS/LOW 3 outputs NPN open collector, 30 VDC, 50 mA max., residual voltage 1.2 V max HIGH/PASS/LOW: 3 outputs PNP open collector, 50 mA max., residual voltage 1.2 V max Linear output Selectable from 2 types of output, voltage or current (selected by slide switch on bottom). Voltage output: .10 to 10 V, output impedance: 40 Ω Current output: 4 to 20 mA Inputs Laser OFF, ZERO reset timing, RESET ON: Short-circuited with 0 V terminal or 1.5 V or less OFF: Open (leakage current: 0.1 mA max.) ON: Short-circuited to supply voltage or within 1.5 V of supply voltage. OFF: Open (leakage current: 0.1 mA max.) Functions Display: Measured value, threshold value, voltage/current, received light amount, and resolution/terminal block output Sensing: Mode, gain, measurement object, head installation Measurement point: Average, peak, bottom, thickness, step, and calculations Filter: Smooth, average, and differentiation Outputs: Scaling, various hold values, and zero reset I/O settings: Linear (focus/correction), judgments (hysteresis and timer), non-measurement, and bank (switching and clear) System: Save, initialization, measurement information display, communications settings, key lock, language, and data load Task: Single task or multitask (up to 4) Status indicators HIGH (orange), PASS (green), LOW (orange), LDON (green), ZERO (green), and ENABLE (green) Segment display Main digital 8-segment red LED, 6 digits Sub-digital 8-segment green LEDs, 6 digits LCD 16 digitsx2 rows, color of characters: green, resolution per character: 5x8 pixel matrix Setting inputs Setting keys Direction keys (UP, DOWN, LEFT, and RIGHT), SET key, ESC key, MENU key, and function keys (1 to 4) Slide switch Threshold switch (2 states: High/Low), mode switch (3 states: FUN, TEACH, and RUN) Power supply voltage 21.6 V to 26.4 VDC (including ripple) Current consumption 0.5 A max. (when sensor head is connected) Ambient temperature Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation) Ambient humidity Operating and storage: 35% to 85% (with no condensation) Degree of protection IP20 Materials Case: Polycarbonate (PC) Weight Approx. 280 g (excluding packing materials and accessories) Accessories Ferrite core (1), instruction sheet ZS-MDC11/MDC41 multi controllers Basic specifications are the same as those for the sensor controllers. The following points, however, are different. (1) Sensor heads cannot be connected. (2) A maximum 9 of controllers can be connected. Control link units are required to connect controllers. (3) Processing functions between controllers: Math functions Controller link unit Connection using the ZS-XCN Data storage units Sensor controllers Model ZS-DSU11 ZS-DSU41 Number of mounted censor heads Cannot be connected Number of connectable controllers 10 controllers max. (ZS-MDC: 1 controller, ZS-HLDC: 9 controllers max.) Connectable controllers ZS-HLDC__, ZS-MDC__ External interface Connection method Serial I/O: connector, other: pre-wired (standard cable length: 2 m) Serial I/O USB 2.0 1 port, full speed (12 Mbps), MINI-B RS-232C 1 port, 115,200 bps max. Outputs 3 outputs: HIGH, PASS, and LOW NPN open-collector, 30 VDC, 50 mA max., residual voltage: 1.2 V max. 3 outputs: HIGH, PASS, and LOW PNP open-collector, 50 mA max., residual voltage: 1.2 V max. Inputs ON: Short-circuited with 0V terminal or 1.5 V or less OFF: Open (leakage current: 0.1 mA max.) ON: Short-circuited to supply voltage or within 1.5 V of supply voltage OFF: Open (leakage current: 0.1 mA max.) Data resolution 32 bits Functions Logging trigger functions Start and stop triggers can be set separately; external triggers, data triggers (self-triggers), and time triggers Other functions External banks, alarm outputs, saved data format customization, and clock Status indicators OUT (orange), PWR (green), ACCESS (orange), and ERR (red) Segment display 8-segment green LEDs, 6 digits LCD 16 digitsx2 rows, color of characters: green, resolution per character: 5x8 pixel matrix Setting inputs Setting keys Direction keys (UP, DOWN, LEFT, and RIGHT), SET key, ESC key, MENU key, and function keys (1 to 4) Slide switch Threshold switch (2 states: High/Low), mode switch (3 states: FUN, TEACH, and RUN) Power supply voltage 21.6 V to 26.4 VDC (including ripple) Current consumption 0.5 A max. Ambient temperature Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation) Ambient humidity Operating and storage: 35% to 85% (with no condensation) Materials Case: Polycarbonate (PC) Weight Approx. 280 g (excluding packing materials and accessories) Accessories Ferrite core (1) instruction sheet, tools for data storage unit: CSV file converter for data storage unit, smart analyzer macro edition (Excel macros for analysis of collected data) 1. Refer to the table of ratings and specifications for details. 2. Refer to the table of ratings and specifications for details. 3. This is the peak-to-peak displacement conversion value in the displacement output at the measuring center distance in high-precision mode when the number of samples to average is set to 128 and the measuring mode is set to the high-resolution mode. The standard workpiece is white aluminum ceramics in diffuse reflection mode and glass in the regular reflection mode. 4. Up to two ZS-XC_B cables can be connected (22 m max.). 5. A robot cable (ZS-XC5BR) is also available. 6. Defined as 1/e² (13.5%) of the center optical intensity at the actual measurement center distance (effective value). The beam diameter is sometimes influenced by the ambient conditions of the workpiece, such as leaked light from the main beam. 7. This is the error in the measured value with respect to an ideal straight line. The standard workpiece is white aluminum ceramics in diffuse reflection mode and glass in the regular reflection mode of the ZS-LD20T/40T/50. Linearity may change according to the workpiece. 8. This is the peak-to-peak displacement conversion value in the displacement output at the measuring center distance in high-precision mode when the number of samples to average is set to 128 and the measuring mode is set to the high-resolution mode. The standard workpiece is white aluminum ceramics in diffuse reflection mode and glass in the regular reflection mode. 9. This is the value obtained at the measuring center distance when the Sensor and workpiece are fixed by an aluminum jig. 10. This value is obtained when the measuring mode is set to the high-speed mode. 11. Defined as 1/e² (13.5%) of the center optical intensity at the actual measurement center distance (effective value). The beam diameter is sometimes influenced by the ambient conditions of the workpiece, such as leaked light from the main beam. 12. This is the error in the measured value with respect to an ideal straight line. The standard workpiece is white aluminum ceramics in diffuse reflection mode and glass in the regular reflection mode of the ZS-LD20T/40T/50. Linearity may change according to the workpiece. 13. This is the peak-to-peak displacement conversion value in the displacement output at the measuring center distance in high-precision mode when the number of samples to average is set to 128 and the measuring mode is set to the high-resolution mode. The standard workpiece is white aluminum ceramics in diffuse reflection mode and glass in the regular reflection mode. 14. This is the value obtained at the measuring center distance when the sensor and workpiece are fixed by an aluminum jig. 15. This value is obtained when the measuring mode is set to the high-speed mode. 16. Control link units are required to connect controllers.
Categories: Monitoring Products Measurement Accessories Advanced Sensors