EATON伊顿 DS7-340SX160N0-N 软启动器

DS7-340SX160N0-N 134922 EATON MOELLER Soft starter, 3p, 160A, 200-480VAC, us 24VAC/DC

EATON - MOELLER

Soft starter, 3p, 160A, 200-480VAC, us=24VAC/DC

Delivery programme Description With internal bypass contacts Function Soft starters for three-phase loads Mains supply voltage (50/60 Hz) U LN V AC 200 - 480 Supply voltage U s 24 V AC/DC Control voltage U C 24 V AC 24 V DC Assigned motor rating (Standard connection, In-Line) at 400 V, 50 Hz P kW 90 at 460 V, 60 Hz P HP 125 Rated operational current AC-53 I e A 160 Startup class CLASS 10 (star-delta replacement) CLASS 20 (heavy starting duty 3 x I e for 45 s) Rated operational voltage U e 200 V 230 V 400 V 480 V Connection to SmartWire-DT no Technical data General Standards IEC/EN 60947-4-2 UL 508 CSA22.2-14 Approvals CE Approvals UL CSA C-Tick UkrSEPRO Climatic proofing Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-10 Ambient temperature Operation ϑ °C -5 - +40 up to 60 at 2% derating per Kelvin temperature rise Storage ϑ °C -25 - +60 Altitude m 0 - 1000 m, above that 1 % derating per 100 m , up to 2000 m Mounting position Vertical Degree of protection Degree of Protection IP20 (terminals IP00) Integrated Protection type IP40 can be achieved on all sides with covers from the NZM range. Protection against direct contact Finger- and back-of-hand proof Overvoltage category/pollution degree II/2 Shock resistance 8 g/11 ms Vibration resistance to EN 60721-3-2 2M2 Radio interference level (IEC/EN 55011) B Static heat dissipation, non-current-dependent P vs W 30 Weight kg 3.7 Main conducting paths Rated operating voltage U e V AC 200 - 480 Supply frequency f LN Hz 50/60 Rated operational current I e A AC-53 I e A 160 Assigned motor rating (Standard connection, In-Line) at 230 V, 50 Hz P kW 45 at 400 V, 50 Hz P kW 90 at 200 V, 60 Hz P HP 50 at 230 V, 60 Hz P HP 60 at 460 V, 60 Hz P HP 125 Overload cycle to IEC/EN 60947-4-2 AC-53a 160 A: AC-53a: 3 - 5: 75 - 10 Internal bypass contacts Technical data for design verification Rated operational current for specified heat dissipation I n A 160 Heat dissipation per pole, current-dependent P vid W 0 Equipment heat dissipation, current-dependent P vid W 30 Static heat dissipation, non-current-dependent P vs W 30 Heat dissipation capacity P diss W 0 Operating ambient temperature min. °C -5 Operating ambient temperature max. °C 40 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 (Show features) (Hide features) Low-voltage industrial components (EG000017) / Soft starter (EC000640) Electric engineering, automation, process control engineering / Low-voltage switch technology / Load breakout, motor breakout / Semiconductor motor controller or soft starter ( [email protected] [ACO300008]) Rated operation current Ie at 40 °C Tu A 160 Rated operating voltage Ue V 230 - 460 Rated power three-phase motor, inline, at 230 V kW 45 Rated power three-phase motor, inline, at 400 V kW 90 Rated power three-phase motor, inside delta, at 230 V kW 0 Rated power three-phase motor, inside delta, at 400 V kW 0 Internal bypass Yes With display No Torque control No Rated surrounding temperature without derating °C 40 Rated control supply voltage Us at AC 50HZ V 24 - 24 Rated control supply voltage Us at AC 60HZ V 24 - 24 Rated control supply voltage Us at DC V 24 - 24 Voltage type for actuating AC/DC Integrated motor overload protection No Approvals Product Standards IEC/EN 60947-4-2; GB 14048.6; UL 508; CSA-C22.2 No 0-M91; CSA-C22.2 No 14-05 CE marking UL File No. E251034 CSA File No. 2511305 CSA Class No. 321106 Specially designed for North America No Suitable for Branch circuits Current Limiting Circuit-Breaker No Max. Voltage Rating 480 V Degree of Protection IP20; UL/CSA Type 1 Dimensions IL03902005Z Instructions for DS7 Soft Starter > > >>

Categories: Softstarters Soft Starters Motor DS - EATON - MOELLER

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。