供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 PN2-160 连接器
PN2-160 266005 EATON MOELLER Switch-disconnector 3p, 160A
EATON - MOELLER
Switch-disconnector 3p, 160A
Delivery programme Product range Switch-disconnectors Protective function Disconnectors/main switches Standard/Approval IEC Installation type Fixed Construction size PN2 Description Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113. Isolating characteristics to IEC/EN 60947-3 and VDE 0660. Busbar tag shroud to VDE 0160 Part 100. Number of poles 3 pole Standard equipment Screw connection Switch positions I, 0 Rated current = rated uninterrupted current I n = I u A 160 Short-circuit protection max. fuse gL-characteristic A gL 250 Technical data Switch-disconnectors Rated surge voltage invariability U imp Main contacts V 8000 Auxiliary contacts V 6000 Rated operational voltage Ue V AC 690 Rated current = rated uninterrupted current I n = I u A 160 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V 690 Use in unearthed supply systems V Technical data for design verification Rated operational current for specified heat dissipation I n A 160 Equipment heat dissipation, current-dependent P vid W 19.66 Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 70 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 Low-voltage industrial components (EG000017) / Switch disconnector (EC000216) Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Switch disconnector ( [email protected] [AKF060010]) Version as main switch Yes Version as maintenance-/service switch Yes Version as safety switch No Version as emergency stop installation Yes Version as reversing switch No Max. rated operation voltage Ue AC V 690 Rated operating voltage V 690 - 690 Rated permanent current Iu A 160 Rated permanent current at AC-21, 400 V A 0 Rated operation power at AC-3, 400 V kW 0 Rated short-time withstand current lcw kA 3.5 Rated operation power at AC-23, 400 V kW 90 Switching power at 400 V kW 0 Conditioned rated short-circuit current Iq kA 100 Number of poles 3 Number of auxiliary contacts as normally closed contact 0 Number of auxiliary contacts as normally open contact 0 Number of auxiliary contacts as change-over contact 0 Motor drive optional No Motor drive integrated No Voltage release optional No Device construction Built-in device fixed built-in technique Suitable for ground mounting Yes Suitable for front mounting 4-hole No Suitable for front mounting center No Suitable for distribution board installation Yes Suitable for intermediate mounting Yes Colour control element Black Type of control element Rocker lever Interlockable Yes Type of electrical connection of main circuit Screw connection Degree of protection (IP), front side IP20 Dimensions IL01206006Z (AWA1230-1916) Circuit-Breaker, basic unit >>
Categories: Circuit Breakers Electrical Power Compact switch-disconnectors PN and N - EATON - MOELLER