EATON伊顿 NZMN2-ME90 断路器-产品快照
- 品牌:
- EATON
- 型号:
- NZMN2-ME90
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 NZMN2-ME90 断路器
NZMN2-ME90 265778 EATON MOELLER Circuit-breaker, 3p, 90A
EATON - MOELLER
Circuit-breaker, 3p, 90A
Delivery programme Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation type Fixed Release system Electronic release Construction size NZM2 Description IEC/EN 60947-4-1, IEC/EN 60947-2 The circuit-breaker fulfills all requirements for AC-3 switching category. R.m.s. value measurement and “thermal memory” adjustable time delay setting to overcome current peaks tr: 2 – 20 s at 6 x Ir also infinity (without overload releases) All AC-3 rating data applies to direct switching by the circuit-breaker under normal operating conditions. If, for example, a contactor takes over AC-3 switching under normal operating conditions, the full rated uninterrupted current applies to the circuit-breaker, In = Iu. Number of poles 3 pole Standard equipment Screw connection Switching capacity 400/415 V 50 Hz I cu kA 50 Rated current = rated uninterrupted current I n = I u A 90 Setting range Overload trip General Standards IEC/EN 60947 Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Ambient temperature, storage °C - 40 - + 80 Operation °C -25 - +70 Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27 g 20 (half-sinusoidal shock 20 ms) Safe isolation to EN 61140 Between auxiliary contacts and main contacts V AC 500 between the auxiliary contacts V AC 300 Weight kg 2.345 Mounting position Vertical and 90° in all directions Basic equipment Box terminal ● - - - Screw connection - ● ● ● Accessories Box terminal - ● ● - Screw connection ● - - ● Tunnel terminal ● ● ● ● Connection on rear ● ● ● ● Flat conductor terminal - - - ● Round copper conductor Box terminal Solid mm 2 1 x (10 - 16) 2 x (6-16) Stranded mm 2 1 x (25 - 185) 2 x (25 - 70) Tunnel terminal Solid mm 2 1 x 16 Stranded mm 2 Stranded mm 2 1 x (25 - 185) Bolt terminal and rear-side connection Direct on the switch Solid mm 2 1 x (10 - 16) 2 x (10 - 16) Stranded mm 2 1 x (25 - 50) 2 x (25 - 50) Al conductors, Cu cable Solid mm 2 1 x 16 Stranded mm 2 Stranded mm 2 1 x (25 - 185) Bolt terminal and rear-side connection Flat copper strip, with holes min. mm 2 x 16 x 0.8 Flat copper strip, with holes max. mm 10 x 24 x 0.8 Cu strip (number of segments x width x segment thickness) Box terminal min. mm 2 x 9 x 0.8 max. mm 10 x 16 x 0.8 (2x) 8 x 15.5 x 0,8 Bolt terminal and rear-side connection Flat copper strip, with holes min. mm 2 x 16 x 0.8 Flat copper strip, with holes max. mm 10 x 24 x 0.8 Copper busbar (width x thickness) mm Bolt terminal and rear-side connection Screw connection M8 Direct on the switch min. mm 16 x 5 max. mm 24 x 8 Control cables mm 2 1 x (0.75 - 2.5) 2 x (0.75 - 1.5) Design verification as per IEC/EN 61439 (Show features) (Hide features) Technical data for design verification Rated operational current for specified heat dissipation I n A 90 Equipment heat dissipation, current-dependent P vid W 6.68 Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 70 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 Low-voltage industrial components (EG000017) / Motor protection circuit-breaker (EC000074) Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Motor protection circuit-breaker ( [email protected] [AGZ529013]) Overload release current setting A 45 - 90 Adjustment range undelayed short-circuit release A 90 - 1260 Thermal protection No Phase failure sensitive Yes Switch off technique Electronic Rated operating voltage V 690 - 690 Rated permanent current Iu A 90 Rated operation power at AC-3, 230 V kW 22 Rated operation power at AC-3, 400 V kW 45 Type of electrical connection of main circuit Screw connection Type of control element Rocker lever Device construction Built-in device fixed built-in technique With integrated auxiliary switch No With integrated under voltage release No Number of poles 3 Rated short-circuit breaking capacity lcu at 400 V, AC kA 50 Degree of protection (IP) IP20 Height mm 184 Width mm 105 Depth mm 149 Characteristics IL01206006Z (AWA1230-1916) Circuit-Breaker, basic unit >>
Categories: Circuit Breakers Electrical Power Circuit-breakers, thermomagnetic releases, up to 1400A - EATON - MOELLER