EATON伊顿 ZEB32-20 电子继电器-产品快照
- 品牌:
- EATON
- 型号:
- ZEB32-20
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 ZEB32-20 电子继电器
ZEB32-20 136488 EATON MOELLER Overload relay, electronic, 4-20A
EATON - MOELLER
Overload relay, electronic, 4-20A
Delivery programme Product range Electronic overload relays ZEB Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102 Description Test/off button Reset pushbutton Manual/auto reset selectable Protection with heavy starting duty (Class 10A-30) Mounting type Direct mounting Earth-fault protection Earth-fault protection none Setting range Overload releases General Standards IEC/EN 60947, VDE 0660, UL, CSA Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open °C -25 - +65 Ambient temperature open max. °C 65 Mechanical shock resistance g 15 Shock duration 10 ms according to IEC 60068-2-27 Degree of Protection IP20 Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Main conducting paths Rated impulse withstand voltage U imp V AC 6000 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V AC 690 Rated operational voltage U e V AC 690 Rated frequency f Hz 50/60 Safe isolation to EN 61140 Between auxiliary contacts and main contacts V AC 600 Between main circuits V AC 600 Terminal capacities mm 2 Solid mm 2 1 x 1.5 - 16 Solid or stranded AWG 1 x 14 - 4 Auxiliary and control circuits Rated impulse withstand voltage U imp V 6000 Overvoltage category/pollution degree III/3 Terminal capacities mm 2 Solid mm 2 2 x (0.75 - 4) Flexible with ferrule mm 2 2 x (0.75 - 2.5) Solid or stranded AWG 2 x (18 - 12) Terminal screw M3.5 Tightening torque Nm 0.8 - 1.2 Tightening torque lb-in 7 Tools Pozidriv screwdriver Size 2 Standard screwdriver mm 1 x 6 Rated insulation voltage U i V AC 500 Rated operational voltage U e V AC 500 Safe isolation to EN 61140 between the auxiliary contacts V AC 240 Conventional thermal current I th A 5 Rated operational current I e A AC-15 Make contact 120 V I e A 1.5 220 V 230 V 240 V I e A 1.5 380 V 400 V 415 V I e A 0.5 500 V I e A 0.5 Break contact 120 V I e A 1.5 220 V 230 V 240 V I e A 1.5 380 V 400 V 415 V I e A 0.9 500 V I e A 0.8 DC-13 L/R - 15 ms 24 V I e A 0.9 60 V I e A 0.75 110 V I e A 0.4 220 V I e A 0.2 Short-circuit rating without welding max. fuse A gG/gL 6 Design verification as per IEC/EN 61439 (Show features) (Hide features) Technical data for design verification Rated operational current for specified heat dissipation I n A 20 Heat dissipation per pole, current-dependent P vid W 0.77 Equipment heat dissipation, current-dependent P vid W 2.3 Static heat dissipation, non-current-dependent P vs W 0 Heat dissipation capacity P diss W 0 Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 65 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 (Show features) (Hide features) Low-voltage industrial components (EG000017) / Electronic overload relay (EC001080) Electric engineering, automation, process control engineering / Low-voltage switch technology / Overload protection device / Electronic overload relay ( [email protected] [AKF076011]) Adjustable current range A 4 - 20 Mounting method Direct attachment Type of electrical connection of main circuit Screw connection Number of auxiliary contacts as normally closed contact 1 Number of auxiliary contacts as normally open contact 1 Number of auxiliary contacts as change-over contact 0 Rated control supply voltage Us at AC 50HZ V 0 - 0 Rated control supply voltage Us at AC 60HZ V 0 - 0 Rated control supply voltage Us at DC V 0 - 0 Release class Adjustable Voltage type for actuating Selfsupplied Approvals Product Standards UL 508; CSA-C22.2 No. 14; IEC/EN 60947-4-1; CE marking UL File No. E1230 UL Category Control No. NKCR CSA File No. 2290956 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Specially designed for North America No Suitable for Branch circuits Max. Voltage Rating 600 V AC Degree of Protection IEC: IP20, UL/CSA Type: - Dimensions IL04210002E Solid-state motor protection relay >>
Categories: Contactor Relays Electronic Motor-Protective Relay Unit ZEB - EATON - MOELLER