EATON伊顿 PKZ-SOL30 直流断路器-产品快照
- 品牌:
- EATON
- 型号:
- PKZ-SOL30
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 PKZ-SOL30 直流断路器
PKZ-SOL30 120939 EATON MOELLER String circuit-breaker, DC current, 2p, 30A
EATON - MOELLER
String circuit-breaker, DC current, 2p, 30A
Delivery programme Product range Switchgear for photovoltaic systems Subrange String circuit-breakers Product range String circuit-breakers Application field Utility buildings Open areas Rated operational voltage U e V 900 Protection class 2 Number of conductors 2 pole Rated operational current 240 V I e A 30 Setting range Short-circuit releases Accessories Page 2 auxiliary contacts NHI-E → 082882 3 shunt releases A-PKZ0 → 073187 3 undervoltage releases U-PKZ0 → 073135 Technical data Rated operational current 240 V I e A 30 Pole 2 pole Rated operational voltage U e V 900 Thermal trip 1.05 - 1.3 x I e Electromagnetic trip block 6 x I e Standards IEC/EN 60 947-2 UL-508, TÜV-certified Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open °C -25 - +60 Mounting position Technical data for design verification Rated operational current for specified heat dissipation I n A 30 Heat dissipation per pole, current-dependent P vid W 0 Equipment heat dissipation, current-dependent P vid W 6.3 Static heat dissipation, non-current-dependent P vs W 0 Heat dissipation capacity P diss W 0 Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 60 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 (Show features) (Hide features) Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228) Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ( [email protected] [AJZ716010]) Rated permanent current Iu A 30 Rated voltage V 900 - 900 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz kA 0 Overload release current setting A 39 - 39 Adjustment range short-term delayed short-circuit release A 0 - 0 Adjustment range undelayed short-circuit release A 180 - 180 Integrated earth fault protection No Type of electrical connection of main circuit Clamp bracket Device construction Built-in device fixed built-in technique Suitable for DIN rail (top hat rail) mounting Yes DIN rail (top hat rail) mounting optional Yes Number of auxiliary contacts as normally closed contact 0 Number of auxiliary contacts as normally open contact 0 Number of auxiliary contacts as change-over contact 0 Switched-off indicator available No With under voltage release No Number of poles 2 Position of connection for main current circuit - Type of control element Turn button Complete device with protection unit Yes Motor drive integrated No Motor drive optional No Degree of protection (IP) IP00 Approvals North America Certification Request filed for UL and CSA Specially designed for North America No Characteristics Characteristic curves >>
Categories: Motor Circuit Protectors Protection Breaker Protection of photovoltaic systems - EATON - MOELLER