EATON伊顿  BPM-O-600/10-IVS 表面

EATON伊顿 BPM-O-600/10-IVS 表面-产品快照

品牌:
EATON
型号:
BPM-O-600/10-IVS

* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.


供应商名称 电话 备注
深圳市格雷创科技有限公司 400-811-6961 微信及邮件咨询,官网:www.gchane.com
上海亦翔电气技术有限公司 021-61488548
深圳市欧捷诚科技有限公司 0755-26650315
苏州哈德控制技术有限公司
上海沪朗电气有限公司 15905696881
杭州捍特电气有限公司 021-51720278
伊顿(中国)投资有限公司 021-52000099

EATON供应商或现货商入驻,请点击>>

产品介绍

EATON伊顿 BPM-O-600/10-IVS 表面

BPM-O-600/10-IVS 111367 EATON MOELLER Surface mounted service distribution board

EATON - MOELLER

Surface mounted service distribution board

Delivery programme Product range Service distribution board IVS Basic function Wall-mounting distribution system Single unit/Complete unit Complete housing Degree of Protection IP54 Description Profi Plus basic enclosures Monoblock enclosure with door and double ward key lock The enclosure can be turned through 180° for cable entry from below. Material Sheet steel Surface finish Polyester powder coating Phosphated RAL 7035, light grey Colour RAL 7035, light grey Information about equipment supplied Including mounting system for the IVS mounting units including insulating surround and mounted insulated support bracket including open cable entry at top, prepared for F3A flanges, closed at bottom Width mm 600 Height mm 1060 Depth mm 270 Technical data General Standards EN 60439-1/3 IEC 62208 Protection class 1 Degree of Protection IP54 Power loss Max. admissible heat dissipation, ambient air temperature +35 °C W 143 Weight kg 38.5 Material characteristics Material Sheet steel Surface treatment Painting, phosphated and polyester powder coating Surface finish Polyester powder coating Phosphated RAL 7035, light grey Colour RAL 7035, light grey Material characteristics Type Door Doors with covered hinges Can be removed from 90° door opening angle 100° (single mounting) Door interlock Hinge handle with roller lever lock Cylinder lock Double-ward lock Material properties Mechanical Impact resistance IK07 Cable entry Open cable entry, prepared for F3A flanges Electrical Rated operational voltage U e V 690 Rated frequency f Hz 50 Rated operational current I e CSA 630 Max. admissible heat dissipation, ambient air temperature +35 °C W 143 Earthings M6 weld stud (base frame) M5 self-tapping screw (enclosure side plate, top/bottom panel) M6 weld stud (door) Design verification as per IEC/EN 61439 (Show features) (Hide features) Technical data for design verification Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees, calculated as per IEC 60890 Individual enclosure for wall mounting P V CO 71 Starting enclosure for wall mounting P V CO 68 Middle enclosure for wall mounting P V CO 66 Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees, calculated as per IEC 60890 Individual enclosure for wall mounting P V CO 143 Starting enclosure for wall mounting P V CO 137 Middle enclosure for wall mounting P V CO 132 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Not relevant to indoor installations. 10.2.5 Lifting Does not apply to enclosures without lifting aids. 10.2.6 Mechanical impact IK07 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES IP54 10.4 Clearances and creepage distances Is the panel builder's responsibility. 10.5 Protection against electric shock < 0.1 Ω; meets the product standard's requirements. 10.6 Incorporation of switching devices and components Is the panel builder's responsibility. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength U i = 440 V AC 10.9.3 Impulse withstand voltage 4 kV 10.9.4 Testing of enclosures made of insulating material Does not apply to metal enclosures. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. 10.13 Mechanical function Meets the product standard's requirements.

Categories: Control Cabinets Switch Boxes Distribution Enclosures

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。