供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 LS-11/LB
LS-11/LB 290175 EATON MOELLER LS-11-LB Position switches
EATON - MOELLER
LS-11-LB Position switches
Delivery programme Basic function Position switches Safety position switches Part group reference LS(M)-… Product range Roller lever Degree of Protection IP66, IP67 Features Complete unit Ambient temperature °C -25 - +70 Description Large Contacts N/O = Normally open 1 N/O N/C = Normally closed 1 NC General Standards IEC/EN 60947 Climatic proofing Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30 Ambient temperature °C -25 - +70 Mounting position As required Degree of Protection IP66, IP67 Terminal capacities mm 2 Solid mm 2 1 x (0.5 - 2.5) Flexible with ferrule mm 2 1 x (0.5 - 1.5) Contacts/switching capacity Rated impulse withstand voltage U imp V AC 4000 Rated insulation voltage U i V 400 Overvoltage category/pollution degree III/3 Rated operational current I e A AC-15 24 V I e A 6 220 V 230 V 240 V I e A 6 380 V 400 V 415 V I e A 4 DC-13 24 V I e A 3 110 V I e A 0.6 220 V I e A 0.3 Control circuit reliability at 24 V DC/5 mA H F Fault probability < 10 -7 , < 1 fault in 107 operations at 5 V DC/1 mA H F Fault probability < 10 -6 , < 1 failure at 5 x 10 6 operations Supply frequency Hz max. 400 Short-circuit rating to IEC/EN 60947-5-1 max. fuse A gG/gL 6 Repetition accuracy mm 0.15 Rated conditional short-circuit current kA 1 Mechanical variables Lifespan, mechanical Operations x 10 6 8 Mechanical shock resistance (half-sinusoidal shock, 20 ms) Standard-action contact g 25 Operating frequency Operations/h Technical data for design verification Rated operational current for specified heat dissipation I n A 6 Heat dissipation per pole, current-dependent P vid W 0.17 Equipment heat dissipation, current-dependent P vid W 0 Static heat dissipation, non-current-dependent P vs W 0 Heat dissipation capacity P diss W 0 Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 70 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 (Show features) (Hide features) Sensors (EG000026) / End switch (EC000030) Electric engineering, automation, process control engineering / Binary sensor technology, safety-related sensor technology / Position switch / Position switch (Type 1) ( [email protected] [AGZ382012]) Width sensor mm 31 Diameter sensor mm 0 Height of sensor mm 61 Length of sensor mm 33.5 Rated operation current Ie at AC-15, 24 V A 6 Rated operation current Ie at AC-15, 125 V A 6 Rated operation current Ie at AC-15, 230 V A 6 Rated operation current Ie at DC-13, 24 V A 3 Rated operation current Ie at DC-13, 125 V A 0.8 Rated operation current Ie at DC-13, 230 V A 0.3 Switching function Slow-action switch Output electronic No Forced opening Yes Number of safety auxiliary contacts 1 Number of contacts as normally closed contact 1 Number of contacts as normally open contact 1 Number of contacts as change-over contact 0 Type of interface None Type of interface for safety communication None Housing according to norm - Construction type housing Cuboid Material housing Plastic Coating housing - Type of control element Roller lever Alignment of the control element - Type of electric connection - With status indication No Suitable for safety functions Yes Explosion safety category for gas None Explosion safety category for dust None Ambient temperature during operating °C -25 - 70 Degree of protection (IP) IP67 Approvals Product Standards IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 12528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Degree of Protection IEC: IP66, 67, UL/CSA Type 3R, 4X (indoor use only), 12, 13 Dimensions >
Categories: Plastic Box LS position switches - EATON - MOELLER