Siemens西门子 3RV2121-4CA10 保护继电器-产品快照
- 品牌:
- Siemens
- 型号:
- 3RV2121-4CA10
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
众业达电气(深圳)有限公司 | 0755-89314987 | irene.li@zyd.cn,13509669211 |
大连鼎宏科技有限公司 | 0411-83693111 | |
东莞市欧能自动化设备有限公司 | 18680502757 | |
福建萤光电气科技发展有限公司 | 18359060969 | |
福州福大自动化科技有限公司 | 0591-28482265 | |
广州锋力五金机电有限公司 | 020-87359185 | |
广州汇尼克机电设备有限公司 | 020-85549829 | |
广州市黄埔区科技开发总公司 | ||
海格曼商贸(上海)有限公司 | 4008215282 | |
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
深圳市行健自动化股份有限公司 | 0755-86336499 | |
深圳市昊普锐科技有限公司 | 0755-82127363 | |
深圳市朗助机电有限公司 | 0755-83975718 | |
深圳市曼伯特实业发展有限公司 | 0755-82032366 | |
苏州工品汇信息科技有限公司 | 4000496999 |
产品介绍
Siemens西门子 3RV2121-4CA10 保护继电器
3RV2121-4CA10 SIEMENS CIRCUIT-BREAKER SZ S0, FOR MOTOR PROTECTION, CLASS 10, W. OVERLOAD RELAY FUNCTION A-R..
SIEMENS
CIRCUIT-BREAKER SZ S0, FOR MOTOR PROTECTION, CLASS 10, W. OVERLOAD RELAY FUNCTION A-RELEASE16...22A, N-RELEASE 286 A, SCREW CONNECTION, STANDARD SW. CAPACITY
product brand name SIRIUS Product designation 3RV2 circuit breaker General technical data: Size of the circuit-breaker S0 Size of contactor can be combined company-specific S00, S0 Product extension ● Auxiliary switch Yes Power loss [W] total typical 8 W Insulation voltage with degree of pollution 3 rated value 690 V Surge voltage resistance rated value 6 kV maximum permissible voltage for safe isolation ● in networks with grounded star point between main and auxiliary circuit 400 V ● in networks with grounded star point between main and auxiliary circuit 400 V Protection class IP ● on the front IP20 ● of the terminal IP20 Shock resistance ● acc. to IEC 60068-2-27 25g / 11 ms Mechanical service life (switching cycles) ● of the main contacts typical 100 000 ● of auxiliary contacts typical 100 000 Electrical endurance (switching cycles) ● typical 100 000 Type of protection Increased safety Certificate of suitability relating to ATEX on request Protection against electrical shock finger-safe Equipment marking acc. to DIN EN 81346-2 Q Ambient conditions: Installation altitude at height above sea level maximum 2 000 m Ambient temperature ● during operation -20 ... +60 °C ● during storage -50 ... +80 °C ● during transport -50 ... +80 °C Temperature compensation -20 ... +60 °C Relative humidity during operation 10 ... 95 % Main circuit: Number of poles for main current circuit 3 Adjustable pick-up value current of the current-dependent overload release 16 ... 22 A Operating voltage ● rated value 690 V ● at AC-3 rated value maximum 690 V Operating frequency rated value 50 ... 60 Hz Operating current rated value 22 A Operating current ● at AC-3 — at 400 V rated value 22 A Operating power ● at AC-3 — at 230 V rated value 5 500 W — at 400 V rated value 11 000 W — at 500 V rated value 11 000 W — at 690 V rated value 18 500 W Operating frequency ● at AC-3 maximum 15 1/h Auxiliary circuit: Design of the auxiliary switch laterally Number of NC contacts ● for auxiliary contacts 0 Number of NO contacts ● for auxiliary contacts 0 Number of CO contacts ● for auxiliary contacts 0 Operating current of auxiliary contacts at AC-15 ● at 24 V 1.5 A ● at 230 V 1.5 A Operating current of auxiliary contacts at DC-13 ● at 24 V 1 A Protective and monitoring functions: Trip class CLASS 10 Design of the overload release thermal Operational short-circuit current breaking capacity (Ics) at AC ● at 240 V rated value 100 kA ● at 400 V rated value 25 kA ● at 500 V rated value 5 kA ● at 690 V rated value 2 kA Maximum short-circuit current breaking capacity (Icu) ● at AC at 240 V rated value 100 kA ● at AC at 400 V rated value 55 kA ● at AC at 500 V rated value 10 kA ● at AC at 690 V rated value 4 kA Breaking capacity short-circuit current (Icn) ● at 1 current path at DC at 150 V rated value 10 kA ● with 2 current paths in series at DC at 300 V rated value 10 kA ● with 3 current paths in series at DC at 450 V rated value 10 kA UL/CSA ratings: Full-load current (FLA) for three-phase AC motor ● at 480 V rated value 22 A ● at 600 V rated value 22 A Yielded mechanical performance [hp] ● for single-phase AC motor — at 110/120 V rated value 1.5 hp — at 230 V rated value 3 hp ● for three-phase AC motor — at 200/208 V rated value 5 hp — at 220/230 V rated value 7.5 hp — at 460/480 V rated value 15 hp Contact rating of auxiliary contacts according to UL C600 / R300 Short-circuit protection Design of the short-circuit trip magnetic Design of the fuse link ● for short-circuit protection of the auxiliary switch required fuse gL/gG: 6 A, quick: 10 A Design of the fuse link for IT network for short-circuit protection of the main circuit ● at 400 V gL/gG 63 A ● at 500 V gL/gG 50 A ● at 690 V gL/gG 50 A Installation/ mounting/ dimensions: Mounting position any Mounting type screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715 Height 97 mm Width 65 mm Depth 96 mm Required spacing ● with side-by-side mounting — forwards 0 mm — Backwards 0 mm — upwards 50 mm — downwards 50 mm — at the side 0 mm ● for grounded parts — forwards 0 mm — Backwards 0 mm — upwards 50 mm — at the side 30 mm — downwards 50 mm ● for live parts — forwards 0 mm — Backwards 0 mm — upwards 50 mm — downwards 50 mm — at the side 30 mm Connections/Terminals: Product function ● removable terminal for auxiliary and control circuit No Type of electrical connection ● for main current circuit screw-type terminals ● for auxiliary and control current circuit screw-type terminals Arrangement of electrical connectors for main current circuit Top and bottom Type of connectable conductor cross-sections ● for main contacts — single or multi-stranded 2x (1 ... 2,5 mm²), 2x (2,5 ... 10 mm²) — finely stranded with core end processing 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm² ● at AWG conductors for main contacts 2x (16 ... 12), 2x (14 ... 8) Type of connectable conductor cross-sections ● for auxiliary contacts — single or multi-stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²) — finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) ● at AWG conductors for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14) Tightening torque ● for main contacts with screw-type terminals 2 ... 2.5 N·m ● for auxiliary contacts with screw-type terminals 0.8 ... 1.2 N·m Design of screwdriver shaft Diameter 5 to 6 mm Design of the thread of the connection screw ● for main contacts M4 ● of the auxiliary and control contacts M3 Safety related data: B10 value ● with high demand rate acc. to SN 31920 5 000 Proportion of dangerous failures ● with low demand rate acc. to SN 31920 50 % ● with high demand rate acc. to SN 31920 50 % Failure rate [FIT] ● with low demand rate acc. to SN 31920 50 FIT T1 value for proof test interval or service life acc. to IEC 61508 10 y Display version ● for switching status Handle
Categories: Motor protection switches