EATON伊顿 DTZ0,63(*/*)* 三相变压器-产品快照
- 品牌:
- EATON
- 型号:
- DTZ0,63(*/*)*
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 DTZ0,63(*/*)* 三相变压器
DTZ0,63(*/*)* 914804 EATON MOELLER Three-phase control/isolation/safety transformer, 630VA, non-standard vol..
EATON - MOELLER
Three-phase control/isolation/safety transformer, 630VA, non-standard voltage
Delivery programme Product range Three-phase DTZ control transformers Rated input voltage V 50 – 950 ± 5 % Rated output voltage V 18.5 – 1000 Rated power kVA 0.63 Short-time rating kVA 1.38 Cu factor 3,00 Notes Transformers with the rated output voltages Technical data for design verification Rated operational current for specified heat dissipation I n A 0 Heat dissipation per pole, current-dependent P vid W 0 Equipment heat dissipation, current-dependent P vid W 0 Static heat dissipation, non-current-dependent P vs W 75 Heat dissipation capacity P diss W 0 Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 40 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 (Show features) (Hide features) Low-voltage industrial components (EG000017) / Three-phase control transformer (EC002485) Electric engineering, automation, process control engineering / Transformer, converter, coil / Control transformer / Three-phase control transformer ( [email protected] [AAB619012]) Built as safety transformer Yes Built as isolating transformer Yes Built as energy saving transformer No Primary voltage 1 V 50 - 950 Primary voltage 2 V 50 - 950 Primary voltage 3 V 50 - 950 Primary voltage 4 V 50 - 950 Primary voltage 5 V 50 - 950 Primary voltage 6 V 50 - 950 Primary voltage 7 V 0 - 0 Primary voltage 8 V 0 - 0 Primary voltage 9 V 0 - 0 Primary voltage 10 V 0 - 0 Secondary voltage 1 V 18.5 - 1000 Secondary voltage 2 V 18.5 - 1000 Secondary voltage 3 V 18.5 - 1000 Secondary voltage 4 V 18.5 - 1000 Secondary voltage 5 V 18.5 - 1000 Secondary voltage 6 V 18.5 - 1000 Secondary voltage 7 V 0 - 0 Secondary voltage 8 V 0 - 0 Secondary voltage 9 V 0 - 0 Secondary voltage 10 V 0 - 0 Wiring system - Rated power VA 630 Type of insulation material acc. IEC 85 B Short-circuit-proof No Relative short circuit voltage % 5.5 Width mm 190 Height mm 224 Depth mm 132 Degree of protection (IP) IP00 Approvals Product Standards UL 506; UL5085-1; UL 5085-2; CSA-C22.2 No. 66; CSA-C22.2 No. 66.1-06; CSA-C22.2 No. 66.2-06; IEC/EN 61558-2-2; CE marking UL File No. E167225 UL Category Control No. XPTQ2, XPTQ8 CSA File No. UL report applies to both US and Canada CSA Class No. – North America Certification UL recognized, certified by UL for use in Canada Specially designed for North America No Suitable for Branch circuits Max. Voltage Rating 600 V AC Degree of Protection IEC: IP00, UL/CSA Type: - Dimensions >
Categories: Current Power Transformers Transformers STN, STI, ST, DTZ and UTI - EATON - MOELLER