Siemens西门子 3RP2505-2AW30 时间继电器-产品快照
- 品牌:
- Siemens
- 型号:
- 3RP2505-2AW30
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
众业达电气(深圳)有限公司 | 0755-89314987 | irene.li@zyd.cn,13509669211 |
大连鼎宏科技有限公司 | 0411-83693111 | |
东莞市欧能自动化设备有限公司 | 18680502757 | |
福建萤光电气科技发展有限公司 | 18359060969 | |
福州福大自动化科技有限公司 | 0591-28482265 | |
广州锋力五金机电有限公司 | 020-87359185 | |
广州汇尼克机电设备有限公司 | 020-85549829 | |
广州市黄埔区科技开发总公司 | ||
海格曼商贸(上海)有限公司 | 4008215282 | |
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
深圳市行健自动化股份有限公司 | 0755-86336499 | |
深圳市昊普锐科技有限公司 | 0755-82127363 | |
深圳市朗助机电有限公司 | 0755-83975718 | |
深圳市曼伯特实业发展有限公司 | 0755-82032366 | |
苏州工品汇信息科技有限公司 | 4000496999 |
产品介绍
Siemens西门子 3RP2505-2AW30 时间继电器
3RP2505-2AW30 SIEMENS TIME RELAY, MULTI-FUNCTION, 1 CO CONT., 13 FUNCTIONS, 7 TIME SET. RANGES, (1,10,100)S..
SIEMENS
TIME RELAY, MULTI-FUNCTION, 1 CO CONT., 13 FUNCTIONS, 7 TIME SET. RANGES, (1,10,100)S 10MIN; (1,10,100) HR 12... 240 V AC/DC AT AC 50/60HZ, LED, SPRING-LOADED TERM. (PUSH-IN)
General technical data: product brand name SIRIUS Product designation 3RP25 timing relays 17.5 mm and 22.5 mm Design of the product 13 functions Mounting position any Product function at the relay outputs Switchover delayed/without delay No Product function non-volatile No Product component ● Relay output Yes ● semi-conductor output No Installation altitude at height above sea level maximum m 2 000 Ambient temperature ● during operation °C -25 ... +60 ● during storage °C -40 ... +85 ● during transport °C -40 ... +85 Relative humidity during operation % 10 ... 95 EMC emitted interference acc. to IEC 61812-1 EN 61000-6-4(3) EMI immunity acc. to IEC 61812-1 EN 61000-6-2 Conducted interference due to burst acc. to IEC 61000-4-4 2 kV network connection / 1 kV control connection Conducted interference due to conductor-earth surge acc. to IEC 61000-4-5 2 kV Conducted interference due to conductor-conductor surge acc. to IEC 61000-4-5 1 kV Electrostatic discharge acc. to IEC 61000-4-2 4 kV contact discharge / 8 kV air discharge Field-bound parasitic coupling acc. to IEC 61000-4-3 10 V/m Surge voltage resistance rated value V 4 000 Power loss [W] total typical W 2 Equipment marking ● acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750 K ● acc. to DIN EN 61346-2 K ● acc. to DIN EN 81346-2 K Category acc. to EN 954-1 none Protection against electrical shock finger-safe Protection class IP IP20 Type of insulation Basic insulation Mechanical service life (switching cycles) typical 10 000 000 Electrical endurance (switching cycles) at AC-15 at 230 V typical 100 000 Operating frequency with 3RT2 contactor maximum 1/h 5 000 Vibration resistance acc. to IEC 60068-2-6 10 ... 55 Hz / 0.35 mm Shock resistance acc. to IEC 60068-2-27 11g / 15 ms Relative repeat accuracy % 1 Recovery time ms 250 Minimum ON period ms 35 Degree of pollution 3 Insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value V 300 Relative setting accuracy relating to full-scale value % 5 Product extension required remote control No Product extension optional remote control No Switching Function: Switching function ● ON-delay Yes ● ON-delay/instantaneous contact No ● passing make contact Yes ● passing make contact/instantaneous contact No ● OFF delay Yes ● flashing asymmetrically starting with interval No ● flashing asymmetrically starting with pulse No ● flashing symmetrically starting with pulse Yes ● flashing symmetrically starting with pulse/instantaneous No ● flashing symmetrically starting with interval Yes ● flashing symmetrically starting with interval/instantaneous No ● star-delta circuit Yes ● star-delta circuit with delay time No Switching function with control signal ● additive ON delay Yes ● passing break contact Yes ● OFF delay Yes ● pulse-shaping Yes ● OFF delay/instantaneous No ● ON-delay/OFF-delay/instantaneous No ● passing break contact/instantaneous No ● additive ON delay/instantaneous No ● ON-delay/OFF-delay Yes ● passing make contact Yes ● passing make contact/instantaneous contact No ● pulse delayed Yes ● pulse delayed/instantaneous No ● pulse-shaping/instantaneous No Switching function of interval relay with control signal ● retrotriggerable with deactivated control signal/instantaneous contact No ● retrotriggerable with activated control signal Yes ● retrotriggerable with activated control signal/instantaneous contact No ● retriggerable with deactivated control signal Yes Design of the control terminal non-floating Yes Control circuit/ Control: Adjustable time s 0.05 ... 360 000 Type of voltage of the control supply voltage AC/DC Control supply voltage frequency 1 Hz 50 ... 60 Control supply voltage 1 ● at AC at 50 Hz V 12 ... 240 ● at AC at 60 Hz V 12 ... 240 ● at DC V 12 ... 240 Operating range factor control supply voltage rated value ● at AC — at 50 Hz 0.85 ... 1.1 — at 60 Hz 0.85 ... 1.1 ● at DC 0.85 ... 1.1 Inrush current peak ● at 24 V A 0.4 ● at 240 V A 5 Duration of inrush current peak ● at 24 V ms 0.3 ● at 240 V ms 0.5 Power loss [W] at AC maximum W 1.09 Power loss [V∙A] at AC maximum V·A 2.95 Auxiliary circuit: Contact reliability of auxiliary contacts one incorrect switching operation of 100 million switching operations (17 V, 5 mA) Material of switching contacts AgSnO2 Operating current of auxiliary contacts ● at AC-15 — at 24 V A 3 — at 250 V A 3 ● at DC-13 — at 24 V A 1 — at 125 V A 0.2 — at 250 V A 0.1 Influence of the surrounding temperature 1% in the whole temperature range to the set runtime Power supply influence 1% in the whole voltage range to the set runtime Test voltage for isolation test kV 2.5 Design of the fuse link for short-circuit protection of the auxiliary switch required fuse gL/gG: 4 A Thermal current A 5 Switching capacity current with inductive load A 0.01 ... 3 Number of NC contacts ● delayed switching 0 ● instantaneous contact 0 Number of NO contacts ● delayed switching 0 ● instantaneous contact 0 Number of CO contacts ● delayed switching 1 ● instantaneous contact 0 Contact rating of auxiliary contacts according to UL R300 / B300 Installation/ mounting/ dimensions: Mounting type screw and snap-on mounting onto 35 mm standard mounting rail Width mm 17.5 Height mm 100 Depth mm 90 Required spacing with side-by-side mounting ● upwards mm 0 ● forwards mm 0 ● at the side mm 0 ● Backwards mm 0 ● downwards mm 0 Required spacing for grounded parts ● Backwards mm 0 ● at the side mm 0 ● upwards mm 0 ● forwards mm 0 ● downwards mm 0 Required spacing for live parts ● downwards mm 0 ● Backwards mm 0 ● at the side mm 0 ● forwards mm 0 ● upwards mm 0 Connections/ Terminals: Type of electrical connection for auxiliary and control current circuit PUSH-IN connection (spring-loaded connection) Product function removable terminal for auxiliary and control circuit Yes Type of connectable conductor cross-sections ● solid 0.5 ... 4 mm² ● finely stranded — without core end processing 0.5 ... 4 mm² — with core end processing 0.5 ... 2.5 mm² ● at AWG conductors — stranded 20 ... 12 — solid 20 ... 12 Ampacity of the bridge terminals maximum A 10
Categories: Function relays