EATON伊顿 T0-2-15679/I1/SVB-产品快照
- 品牌:
- EATON
- 型号:
- T0-2-15679/I1/SVB
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 T0-2-15679/I1/SVB
T0-2-15679/I1/SVB 207149 EATON MOELLER Main switch, 3 pole + 1 N/O, 20 A, Emergency-Stop function, 90 °, Loc..
EATON - MOELLER
Main switch, 3 pole + 1 N/O, 20 A, Emergency-Stop function, 90 °, Lockable in the 0 (Off) position, surface mounting
Delivery programme Product range Main switch maintenance switch Repair switch Part group reference T0 Emergency STOP Emergency switching off function With red rotary handle and yellow locking ring Number of poles 3 pole Auxiliary contacts General Standards IEC/EN 60947, VDE 0660, IEC/EN 60204 Switch-disconnector according to IEC/EN 60947-3 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Enclosed °C -25 - +40 Overvoltage category/pollution degree III/3 Rated impulse withstand voltage U imp V AC 6000 Mechanical shock resistance g 15 Mounting position As required Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Contacts Mechanical variables Number of poles 3 pole Auxiliary contacts N/O 1 N/C 0 Electrical characteristics Rated operational voltage U e V AC 690 Rated uninterrupted current I u A 20 Note on rated uninterrupted current ! u Rated uninterrupted current Iu is specified for max. cross-section. Load rating with intermittent operation, class 12 AB 25 % DF x I e 2 AB 40 % DF x I e 1.6 AB 60 % DF x I e 1.3 Short-circuit rating Fuse A gG/gL 20 Rated short-time withstand current (1 s current) I cw A rms 320 Note on rated short-time withstand current lcw Current for a time of 1 second Rated conditional short-circuit current Iq kA 6 Switching capacity cos ϕ rated making capacity as per IEC 60947-3 A 130 Rated breaking capacity cos ϕ to IEC 60947-3 A 230 V A 100 400/415 V A 110 500 V A 80 690 V A 60 Safe isolation to EN 61140 between the contacts V AC 440 Current heat loss per contact at I e W 0.6 Current heat loss per auxiliary circuit at I e (AC-15/230 V) CO 0.6 Lifespan, mechanical Operations x 10 6 > 0.4 Maximum operating frequency Operations/h 1200 AC AC-3 Rating, motor load switch P kW 220 V 230 V P kW 3 230 V Star-delta P kW 5.5 400 V 415 V P kW 5.5 400 V Star-delta P kW 7.5 500 V P kW 5.5 500 V Star-delta P kW 7.5 690 V P kW 4 690 V Star-delta P kW 5.5 Rated operational current motor load switch 230 V I e A 11.5 230 V star-delta I e A 20 400V 415 V I e A 11.5 400 V star-delta I e A 20 500 V I e A 9 500 V star-delta I e A 15.6 690 V I e A 4.9 690 V star-delta I e A 8.5 AC-21A Rated operational current switch 440 V I e A 20 AC-23A Motor rating AC-23A, 50 - 60 Hz P kW 230 V P kW 3 400 V 415 V P kW 5.5 500 V P kW 7.5 690 V P kW 5.5 Rated operational current motor load switch 230 V I e A 13.3 400 V 415 V I e A 13.3 500 V I e A 13.3 690 V I e A 7.6 DC DC-1, Load-break switches L/R = 1 ms Rated operational current I e A 10 Voltage per contact pair in series V 60 DC-21A I e A Rated operational current I e A 1 Contacts Quantity 1 DC-23A, motor load switchL/R = 15 ms 24 V Rated operational current I e A 10 Contacts Quantity 1 48 V Rated operational current I e A 10 Contacts Quantity 2 60 V Rated operational current I e A 10 Contacts Quantity 3 120 V Rated operational current I e A 5 Contacts Quantity 3 240 V Rated operational current I e A 5 Contacts Quantity 5 DC-13, Control switches L/R = 50 ms Rated operational current I e A 10 Voltage per contact pair in series V 32 Control circuit reliability at 24 V DC, 10 mA Fault probability H F < 10 -5 , < 1 fault in 100000 operations Terminal capacities Solid or stranded mm 2 1 x (1 - 2,5) 2 x (1 - 2,5) Flexible with ferrules to DIN 46228 mm 2 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) Terminal screw M3.5 Max. tightening torque Nm 1 Technical safety parameters: Notes B10 d values as per EN ISO 13849-1, table C1 Design verification as per IEC/EN 61439 (Show features) (Hide features) Technical data for design verification Rated operational current for specified heat dissipation I n A 20 Heat dissipation per pole, current-dependent P vid W 0.6 Equipment heat dissipation, current-dependent P vid W 0 Static heat dissipation, non-current-dependent P vs W 0 Heat dissipation capacity P diss W 0 Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 40 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Please enquire 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 (Show features) (Hide features) Low-voltage industrial components (EG000017) / Switch disconnector (EC000216) Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Switch disconnector ( [email protected] [AKF060010]) Version as main switch Yes Version as maintenance-/service switch Yes Version as safety switch No Version as emergency stop installation Yes Version as reversing switch No Max. rated operation voltage Ue AC V 690 Rated operating voltage V 690 - 690 Rated permanent current Iu A 20 Rated permanent current at AC-21, 400 V A 20 Rated operation power at AC-3, 400 V kW 5.5 Rated short-time withstand current lcw kA 0.32 Rated operation power at AC-23, 400 V kW 5.5 Switching power at 400 V kW 5.5 Conditioned rated short-circuit current Iq kA 6 Number of poles 3 Number of auxiliary contacts as normally closed contact 0 Number of auxiliary contacts as normally open contact 1 Number of auxiliary contacts as change-over contact 0 Motor drive optional No Motor drive integrated No Voltage release optional No Device construction Complete device in housing Suitable for ground mounting Yes Suitable for front mounting 4-hole No Suitable for front mounting center No Suitable for distribution board installation No Suitable for intermediate mounting No Colour control element Red Type of control element Door coupling rotary drive Interlockable Yes Type of electrical connection of main circuit Screw connection Degree of protection (IP), front side IP65 Dimensions IL03801007Z (AWA1150-1687) Cam switch: Surface mounting enclosure >>
Categories: Switches Switch-disconnectors - main switches - EATON - MOELLER