EATON伊顿  T0-2-15679/I1/SVB

EATON伊顿 T0-2-15679/I1/SVB-产品快照

品牌:
EATON
型号:
T0-2-15679/I1/SVB

* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.


供应商名称 电话 备注
深圳市格雷创科技有限公司 400-811-6961 微信及邮件咨询,官网:www.gchane.com
上海亦翔电气技术有限公司 021-61488548
深圳市欧捷诚科技有限公司 0755-26650315
苏州哈德控制技术有限公司
上海沪朗电气有限公司 15905696881
杭州捍特电气有限公司 021-51720278
伊顿(中国)投资有限公司 021-52000099

EATON供应商或现货商入驻,请点击>>

产品介绍

EATON伊顿 T0-2-15679/I1/SVB

T0-2-15679/I1/SVB 207149 EATON MOELLER Main switch, 3 pole + 1 N/O, 20 A, Emergency-Stop function, 90 °, Loc..

EATON - MOELLER

Main switch, 3 pole + 1 N/O, 20 A, Emergency-Stop function, 90 °, Lockable in the 0 (Off) position, surface mounting

Delivery programme Product range Main switch maintenance switch Repair switch Part group reference T0 Emergency STOP Emergency switching off function With red rotary handle and yellow locking ring Number of poles 3 pole Auxiliary contacts General Standards IEC/EN 60947, VDE 0660, IEC/EN 60204 Switch-disconnector according to IEC/EN 60947-3 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Enclosed °C -25 - +40 Overvoltage category/pollution degree III/3 Rated impulse withstand voltage U imp V AC 6000 Mechanical shock resistance g 15 Mounting position As required Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Contacts Mechanical variables Number of poles 3 pole Auxiliary contacts N/O 1 N/C 0 Electrical characteristics Rated operational voltage U e V AC 690 Rated uninterrupted current I u A 20 Note on rated uninterrupted current ! u Rated uninterrupted current Iu is specified for max. cross-section. Load rating with intermittent operation, class 12 AB 25 % DF x I e 2 AB 40 % DF x I e 1.6 AB 60 % DF x I e 1.3 Short-circuit rating Fuse A gG/gL 20 Rated short-time withstand current (1 s current) I cw A rms 320 Note on rated short-time withstand current lcw Current for a time of 1 second Rated conditional short-circuit current Iq kA 6 Switching capacity cos ϕ rated making capacity as per IEC 60947-3 A 130 Rated breaking capacity cos ϕ to IEC 60947-3 A 230 V A 100 400/415 V A 110 500 V A 80 690 V A 60 Safe isolation to EN 61140 between the contacts V AC 440 Current heat loss per contact at I e W 0.6 Current heat loss per auxiliary circuit at I e (AC-15/230 V) CO 0.6 Lifespan, mechanical Operations x 10 6 > 0.4 Maximum operating frequency Operations/h 1200 AC AC-3 Rating, motor load switch P kW 220 V 230 V P kW 3 230 V Star-delta P kW 5.5 400 V 415 V P kW 5.5 400 V Star-delta P kW 7.5 500 V P kW 5.5 500 V Star-delta P kW 7.5 690 V P kW 4 690 V Star-delta P kW 5.5 Rated operational current motor load switch 230 V I e A 11.5 230 V star-delta I e A 20 400V 415 V I e A 11.5 400 V star-delta I e A 20 500 V I e A 9 500 V star-delta I e A 15.6 690 V I e A 4.9 690 V star-delta I e A 8.5 AC-21A Rated operational current switch 440 V I e A 20 AC-23A Motor rating AC-23A, 50 - 60 Hz P kW 230 V P kW 3 400 V 415 V P kW 5.5 500 V P kW 7.5 690 V P kW 5.5 Rated operational current motor load switch 230 V I e A 13.3 400 V 415 V I e A 13.3 500 V I e A 13.3 690 V I e A 7.6 DC DC-1, Load-break switches L/R = 1 ms Rated operational current I e A 10 Voltage per contact pair in series V 60 DC-21A I e A Rated operational current I e A 1 Contacts Quantity 1 DC-23A, motor load switchL/R = 15 ms 24 V Rated operational current I e A 10 Contacts Quantity 1 48 V Rated operational current I e A 10 Contacts Quantity 2 60 V Rated operational current I e A 10 Contacts Quantity 3 120 V Rated operational current I e A 5 Contacts Quantity 3 240 V Rated operational current I e A 5 Contacts Quantity 5 DC-13, Control switches L/R = 50 ms Rated operational current I e A 10 Voltage per contact pair in series V 32 Control circuit reliability at 24 V DC, 10 mA Fault probability H F < 10 -5 , < 1 fault in 100000 operations Terminal capacities Solid or stranded mm 2 1 x (1 - 2,5) 2 x (1 - 2,5) Flexible with ferrules to DIN 46228 mm 2 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) Terminal screw M3.5 Max. tightening torque Nm 1 Technical safety parameters: Notes B10 d values as per EN ISO 13849-1, table C1 Design verification as per IEC/EN 61439 (Show features) (Hide features) Technical data for design verification Rated operational current for specified heat dissipation I n A 20 Heat dissipation per pole, current-dependent P vid W 0.6 Equipment heat dissipation, current-dependent P vid W 0 Static heat dissipation, non-current-dependent P vs W 0 Heat dissipation capacity P diss W 0 Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 40 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Please enquire 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 (Show features) (Hide features) Low-voltage industrial components (EG000017) / Switch disconnector (EC000216) Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Switch disconnector ( [email protected] [AKF060010]) Version as main switch Yes Version as maintenance-/service switch Yes Version as safety switch No Version as emergency stop installation Yes Version as reversing switch No Max. rated operation voltage Ue AC V 690 Rated operating voltage V 690 - 690 Rated permanent current Iu A 20 Rated permanent current at AC-21, 400 V A 20 Rated operation power at AC-3, 400 V kW 5.5 Rated short-time withstand current lcw kA 0.32 Rated operation power at AC-23, 400 V kW 5.5 Switching power at 400 V kW 5.5 Conditioned rated short-circuit current Iq kA 6 Number of poles 3 Number of auxiliary contacts as normally closed contact 0 Number of auxiliary contacts as normally open contact 1 Number of auxiliary contacts as change-over contact 0 Motor drive optional No Motor drive integrated No Voltage release optional No Device construction Complete device in housing Suitable for ground mounting Yes Suitable for front mounting 4-hole No Suitable for front mounting center No Suitable for distribution board installation No Suitable for intermediate mounting No Colour control element Red Type of control element Door coupling rotary drive Interlockable Yes Type of electrical connection of main circuit Screw connection Degree of protection (IP), front side IP65 Dimensions IL03801007Z (AWA1150-1687) Cam switch: Surface mounting enclosure >>

Categories: Switches Switch-disconnectors - main switches - EATON - MOELLER

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。