EATON伊顿 NZMH2-4-A40-SVE 模块
NZMH2-4-A40-SVE 113367 EATON MOELLER Circuit-breaker, 4p, 40A, plug-in module
EATON - MOELLER
Circuit-breaker, 4p, 40A, plug-in module
Delivery programme Product range Circuit-breaker Protective function System and cable protection Standard/Approval IEC Installation type Plug-in units Release system Thermomagnetic release Construction size NZM2 Description Set value in neutral conductor is synchronous with set value Ir of main pole. Number of poles 4 pole Standard equipment Screw connection Switching capacity 400/415 V 50 Hz I cu kA 150 Rated current = rated uninterrupted current Rated current = rated uninterrupted current I n = I u A 40 Neutral conductor % of phase conductor CSA 100 Setting range Overload trip General Standards IEC/EN 60947 Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Ambient temperature, storage °C - 40 - + 80 Operation °C -25 - +70 Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27 g 20 (half-sinusoidal shock 20 ms) Safe isolation to EN 61140 Between auxiliary contacts and main contacts V AC 500 between the auxiliary contacts V AC 300 Weight kg 3.5 Mounting position Vertical and 90° in all directions Switching of one pole via two series contacts Switching of one pole via three series contacts Technical data for design verification Rated operational current for specified heat dissipation I n A 40 Equipment heat dissipation, current-dependent P vid W 13.44 Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 70 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228) Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ( [email protected] [AJZ716010]) Rated permanent current Iu A 40 Rated voltage V 690 - 690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz kA 150 Overload release current setting A 32 - 40 Adjustment range short-term delayed short-circuit release A 0 - 0 Adjustment range undelayed short-circuit release A 320 - 400 Integrated earth fault protection No Type of electrical connection of main circuit Screw connection Device construction Built-in device plug-in technique Suitable for DIN rail (top hat rail) mounting No DIN rail (top hat rail) mounting optional Yes Number of auxiliary contacts as normally closed contact 0 Number of auxiliary contacts as normally open contact 0 Number of auxiliary contacts as change-over contact 0 Switched-off indicator available No With under voltage release No Number of poles 4 Position of connection for main current circuit Front side Type of control element Rocker lever Complete device with protection unit Yes Motor drive integrated No Motor drive optional Yes Degree of protection (IP) IP20 Characteristics >>
Categories: Circuit Breakers Electrical Power NZM2 - EATON - MOELLER