EATON伊顿 IZM20N4-V16F-产品快照
- 品牌:
- EATON
- 型号:
- IZM20N4-V16F
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
上海亦翔电气技术有限公司 | 021-61488548 | |
深圳市欧捷诚科技有限公司 | 0755-26650315 | |
苏州哈德控制技术有限公司 | ||
上海沪朗电气有限公司 | 15905696881 | |
杭州捍特电气有限公司 | 021-51720278 | |
伊顿(中国)投资有限公司 | 021-52000099 |
产品介绍
EATON伊顿 IZM20N4-V16F
IZM20N4-V16F 123559 EATON MOELLER Automatic switch, 4P, 1600A, fixed
EATON - MOELLER
Automatic switch, 4P, 1600A, fixed
Delivery programme Product range Air circuit-breakers/switch-disconnectors Product range Open circuit-breakers Current Range over 4000 A Protective function Selective operation Installation type Fixed Construction size IZM20 Release system Electronic release Standard/Approval IEC Number of poles 4 pole Degree of Protection IP20, IP55 with protective cover, IP41 with door sealing frame Rated current = rated uninterrupted current I n = I u A 1600 Breaking capacity Icu = Ics to 440 V 50/60 Hz I cu kA 65 Breaking capacity Ics to 440 V 50/60 Hz I cs kA 65 Overload release, min. I r A 640 Overload release, max. I r A 1600 Non-delayed I i = I n x … 2 - 10, OFF Delayed I sd = I r x … 2 - 10 Notes Including rear connection main terminals and secondary terminal blocks according to ordered breaker options. Technical data General Standards IEC/EN 60947 Ambient temperature Storage ϑ °C -25 - +70 (device with LCD-display -20 - +70) Operating (open) °C -25 - +70 (device with LCD-display -20 - +70) Mounting position > > Utilization category B Degree of Protection IP20, IP55 with protective cover, IP41 with door sealing frame Direction of incoming supply as required Main conducting paths Rated current = rated uninterrupted current I n = I u A 1600 Rated uninterrupted current at 50 °C I u A 1600 Rated uninterrupted current at 60 °C I u A 1500 Rated uninterrupted current at 70 °C I u A 1350 Rated impulse withstand voltage U imp V AC 8000 Rated operational voltage U e V AC 690 Use in IT electrical power networks up to U = 440 V I IT kA 23 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V 1000 Switching capacity Rated short-circuit making capacity I cm up to 440 V 50/60 Hz I cm kA 136 up to 690 V 50/60 Hz I cm kA 137 Rated short-time withstand current 50/60 Hz t = 1 s I cw kA 65 t = 3 s I cw kA 40 Rated short-circuit breaking capacity I cn I cn IEC/EN 60947 operating sequence I cu O-t-CO up to 240 V 50/60 Hz I cu kA 65 up to 440 V 50/60 Hz I cu kA 65 up to 690 V 50/60 Hz I cu kA 65 IEC/EN 60947 operating sequence I cs O-t-CO-t-CO up to 240 V 50/60 Hz I cs kA 65 up to 440 V 50/60 Hz I cs kA 65 up to 690 V 50/60 Hz I cs kA 65 Operating times Closing delay via spring release ms 30 Break times ms 40 Total opening delay via shunt release ms 35 Total opening delay via undervoltage release ms 35/70 Total opening delay on non-delayed short-circuit release (up to complete arc quenching) ms 35 Maximum operating frequency Operations/h 60 Heat dissipation at rated current I n Fixed mounting W 180 Withdrawable units (switch with cassette) W 360 Weight Fixed mounting 3-pole kg 43 4-pole kg 54 Withdrawable 3-pole kg 48 4-pole kg 62 Cassette 3 pole kg 34 4 pole kg 38 Terminal capacities Copper bar Fixed mounting Black mm 2 x 5 x 100 Withdrawable units Black mm 2 x 5 x 100 Permissible continuous current for circuit‐breakers operating in switchboards at various internal ambient temperatures. The switchboard’s internal ambient temperature should be estimated using the calculation methods of IEC regulation. Other technical data (sheet catalogue) >Tripping characteristics for universal and selective protection >Notes - tripping characteristics Design verification as per IEC/EN 61439 (Show features) (Hide features) Technical data for design verification Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 70 Dimensions > Additional product information (links) > >Notes - tripping characteristics > >Tripping characteristics for universal and selective protection
Categories: