RD5110 温度记录仪

Hybrid Chart Recorder, 250 mm (10")

RD5100 series chart recorders are 250 mm (10") hybrid recorders with multi-range input. Innovative design high performance recorder provides high accuracy, ±0.05%; high speed scanning, 0.1 second for 36 points and high speed recording, 1 line in 3 seconds. Simple operational keys and PC setting functions drastically improved usability of recording system. SPECIFICATIONS Input Number of Measuring Points: 12, 24 and 36 points Input Types: Universal (refer to the table of inputs) Range Setting: Input type and range are set with front keys Scale Setting: The minimum and maximum values and unit are set for each point with front keys Setting Range: -30,000 to 30,000 Decimal Points: Optional setting Indication Accuracy: Refer to the table of inputs on page S-35d Temperature Drift: 0.1% FS/ 10°C Measuring Period: 0.1 sec/channel Reference Junction Compensation Accuracy: K, E, J, T, N, Platinel II: ±0.5°C (33°F) or less [0°C (32°F) or more when measuring] R, S, WRe5-WRe26, NiMo-Ni, U, L: ±1.0°C (34°F) or less [only when the ambient temperature is 23°C (73°F) ±5°C (41°F)] Input Resolution: Approx. 1/40,000 (standard range conversion) Burnout: Select with/without burnout for each input Allowable Signal Source Resistance: Thermocouple Inputs, DC Voltage Input (10 mV): 500Ω or less (without burnout) DC Voltage Input (Except 10 mV): 100Ω or less Resistance Thermometer Inputs : 10Ω or less/ line, three lines are common, Pt100, JPt100 Input Resistance: Thermocouple Input, DC Voltage Input: Approx. 1MΩ Maximum Input Applied Voltage: ±20 Vdc Input Correction: Zero/span correction and shift correction for each channel Maximum Common Mode Coltage: 30 Vac (support LVD) Common Mode Rejection Ratio: 130dB Series Mode Rejection Ratio: 50dB (only when the peak value of noise is below standard range) Terminal Board: Detachable type, removable for wire connection Recording Specifications Recording System: Raster scan system, 10-color wire dot printing Recording and Recording Color: Analog Recording: Color can be specified for each channel as required 10 colors (red, purple-red, orange, brown, green, yellow-green, blue-green, purple, purple-blue, black) Digital Recording and Logging Recording: Black Message Printing: Black List Printing: Black Chart Paper: Fan-fold type; overall width 318 mm (12.5"), total length 20 m (65.6'); effective recording width 250 mm (10") (analog recording) Chart Speed: 1 to 1500 mm/H [in 1 mm/H steps] Skip Function: Analog recording, digital recording and digital display can be set independently from recording slip Recording Compensation: Independent setting of zero spans are available Display Specifications Digital Display: Color LCD panel RGB (640 x 240 dot) Display Size: 149.8 W x 57.4 mm H (5.8 W x 2.25" H) Setting Display: Common to digital display* Display Contents: Digital display Channel Display: One-point/multiple points continuous/sequential indication change Display Measuring Value of Each Channel: One-point/multiple points continuous/sequential indication change Clock Display: Hour/Minute/ Second/Tag/Unit Chart Speed Display Status Display: Record On: Lights during recording; LED Key Lock: Lights during key lock Alarm: Lights during alarm activated; LED Chart End: Lights just before record ending Fail: Lights during unit abnormal time * Sharing LED and setting display Alarm Specifications Alarm Display: Occurrence CH No, data is displayed in red when alarm occurs Alarm Types: High limit, low limit Alarm Setting Method: Individual setting for each point four levels/ channels Alarm Output: See option specification Setting and Operational Specifications Key Types, Operation: Func1: Switching each function Func2: Switching each function Enter: Setting a change of parameter for each mode Menu: Specifying each setting function Esc: Used to escape in the middle of setting Used to switch channels when specifying the parameter on cursor Used to switch channels when specifying the parameter on cursor Used to move cursor to the right Used to move cursor to the left Rec: Analog recording, digital recording, printing, switching chart ON/OFF DataP: Digital recording of latest data Feed: Fast-forwarding chart paper Shift: Specifying key . _ =: Setting characters of “. _ =” @ + -: Setting characters of “@ + -” 0 * /: Setting parameter value 0 and character of “* / ” 1ABC: Setting parameter value 1 and character of “ABC ” 2DEF: Setting parameter value 2 and character of “DEF” 3GHI: Setting parameter value 3 and character of “GHI” 4JKL: Setting parameter value 4 and character of “JKL” 5MNO: Setting parameter value 5 and character of “MNO” 6PQR: Setting parameter value 6 and character of “PQR” 7STU: Setting parameter value 7 and character of “STU” 8VWX: Setting parameter value 8 and character of “VWX” 9YZ: Setting parameter value 9 and character of “YZ” Recording Operation: Record On/Off: Recording operation ON/OFF* Data Print: Printing measuring data* Feed: Fast-forwarding chart paper * Two actions are taken to operate General Specifications Rated Power Voltage: 100 to 240 Vac (universal power supply) 50/60Hz Maximum Power Consumption: 100V A Reference Operating Condition: Ambient Temperature/Humidity Range: 21 to 25°C (70 to 77°F), 45 to 65% RH Power Voltage: 90 to 264V Power Frequency: 50/60Hz ±2% Attitude: Forward/Backward/left/right within 3° Warm-Up Time: 1 hour or longer Normal Operating Condition: Ambient Temperature/Humidity Range: 0 to 40°C (32 to 104°F), 20 to 80% RH Power Voltage: 90 to 264V Power Frequency: 50/60Hz ±2% Attitude: Forward/backward/left/right within 3° Transportation Condition: At the packed condition on shipment from our factory Ambient Temperature/Humidity -20 to 60°C (-4 to 140°F), 5 to 90%RH (no dew condensation) Vibration: 10 to 60 Hz, 4.9 m (16')/ S2 (0.5G or less) Impact: 392 m (1.3')/S2 (approx. 40G or less) Storage Condition: Ambient Temperature: -20 to 60°C (-4 to 140°F), 5 to 90% RH (no dew condensation) Working Condition: Working Temperature Range: 0 to 40°C (32 to 104°F) Working Humidity Range: 20 to 80% RH Power Failure Protection: Programmed parameters stored into EEPROM memory clock circuit sustained for 5 years or longer by a lithium battery (at the operation of 8 hours or longer per day) Insulation Resistance: Between Primary Terminals and Protective Conductor Terminals: 20MΩ or more at 500 Vdc Between Secondary Terminals and Protective Conductor Terminals: 20MΩ or more at 500 Vdc Between Primary Terminals and Secondary Terminals: 20MΩ or more at 500 Vdc Dielectric Strength: Between Primary Terminals and Protective Conductor Terminals: 1 minute at 1500 Vac Between Secondary Terminals and Protective Conductor Terminals: 1 minute at 500 Vac Between Primary Terminals and Secondary Terminals: 1 minute at 1500 Vac Note 1: Primary Terminals: Power terminal, alarm output terminal, output relay terminal Secondary Terminals: Measuring input terminal, communication terminal, external drive terminal Note 2: When testing insulation resistance and dielectric strength, please short-circuit every terminals of primary and secondary terminals before the test; test without short-circuiting terminals can damage instruments Case Assembly Material: Door (Frame): ABS resin Front Panel: Soda glass Back Case: Normal steel Color: Door (Frame): White (equivalent to DIC546 1.2) Front Panel: Transparent Back Case: White (equivalent to DIC546 1.2) Mounting: Panel mounting Weight: About 15 kg (33 lb) (full option) Dimensions: 400 W x 260 H x 300 mm D (15.7 W x 10.2 H x 11.8" D) Panel Cut Dimensions: 388 x 248 mm (15.2 x 9.7") Terminal Screws: Measuring Input, Alarm Terminals: M3.5 Power, Protective Conductor Terminal, External Drive Terminal, Communication Terminal: M4 Chart Paper Illumination: White LED

High Speed Scanning at 36 Points/Sec and High-Speed Recording High Accuracy of 0.05% Various Industrial Values Can be Measured at the Same Time with Selectable Ranges Superior Ease of Operation Engineering Port is Provided (USB) Anti-Noise Countermeasures Communication Interfaces are Available Recording and Calculation of Data Communication Input

Home Temperature Recorders Recorder Selection Guide

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。