KANE456
Kane 456 Domestic Flue Gas & Boiler Analyser
Kane
Simultaneously measure and display 6 results Compatible with various different fuel types Test CO, CO2, oxygen, temperature, efficiency and much more Kane 456 Domestic Flue Gas & Boiler Analyser Details Kane's 456 can show up to six measurements at the same time on its built-in screen, allowing you to work faster when installing and servicing domestic oil and gas appliances. This flue gas analyser is suitable for use with several fuel types: natural gas, butane, propane, LPG, 28 sec oil, 35 sec oil and wood pellets. It's ideally suited for both combustion performance and combustion efficiency checks and is fast, easy to use and performs a wide variety of different measurement types. With the Kane 456, it's possible to measure carbon dioxide (Co2), carbon monoxide (CO), differential temperature and differential pressure. It can also be used to calculate oxygen (O2), CO/CO2 ratio, losses and overall combustion efficiency (net or condensing gross). An integrated CO sensor will also test the level of carbon monoxide in ambient air, allowing room CO tests for up to 30 minutes to be performed. At the touch of a button, all parameters can be saved directly into the analyser's memory. This data can be viewed back on the analyser, or can be sent to an optional Kane IRP printer for fast printing wherever you are. Kane 456 Domestic Flue Gas and Boiler Analyser Key Features Structured commission test Rotary switch with easy test selection Data hold function temporarily freezes a value on the screen Perform combustion, pressure, let-by and tightness, temperature, CO build up and comission tests Direct CO2 measurements with infrared sensor Measure carbon monoxide from 0-2000ppm Differential temperature measurements High accuracy differential pressure meter - ±80mbar Compatible with natural gas, butane, propane, LPG, 28 sec oil, 35 sec oil and wood pellets Integrated memory can store up to 60 combustion tests, 20 AUX tests, 20 let-by/tightness tests, 20 temp/pressure tests, 20 room CO tests and 20 commissioning tests Wireless printing (requires optional IRP printer, sold separately) Built-in CO monitor for ambient CO tests What's Included? Kane 456 Flue Gas Analyser Probe Pressure Connectors Charger Manual Calibration Report
Parameter Range Resolution Accuracy Temp Measurements Flue Temperature 0 to 600°C 0.1°C ±2.0°C ±0.3% reading Inlet Temperature (Internal Sensor) 0-50°C 0.1°C ±1.0°C ±0.3% reading Inlet Temperature (External Sensor) 0 to 600°C 0.1°C ±2.0°C ±0.3% reading Flue Gas Measurements Oxygen 0 to 21% 0.1% ±0.3% Carbon Monoxide 0-20ppm 21 to 2000ppm nominal 4000ppm max for 15 minutes 1ppm ±3ppm ±5% reading Carbon Dioxide 0-20% 0.1% ±0.3% volume Efficiency (Net or Gross) 0 to 99.9% 0.1% ±1.0% reading Efficiency High (C) 0 to 119.9% 0.1% ±1.0% reading Excess Air 0 to 250% 0.1% ±0.2% reading CO/CO2 Ratio 0 to 0.999 0.0001 ±5% reading Pressure (Differential) Nominal Range ±80mbar Maximum over range without damage to sensor is ±400mbar ±0.2mbar ±1mbar±80mbar Maximum 0.001mbar <25mbar ±0.005mbar ±0.03mbar ±3% of reading General Specs Pre-Programmed Fuels Natural gas, propane, butane, LPG, Light Oils (28/35 sec), Wood Pellets Storage Capacity 60 combustion tests 20 pressure and temperature tests 20 tightness tests 20 temperature tests 20 room CO tests 20 commissioning tests Ambient Operating Range 0 to 45°C 10 to 90% RH non-condensing Battery Type/Life 4 x AA cells >8 hours using alkaline AA cells Chargers (Optional) 220V charger, for NiMH batteries only 12V in vehicle charger, for NiMH batteries only Weight 0.8kg (handset with protective rubber cover) Dimensions Handset: 200 x 45 x 90mm Probe: 300mm long including handle. 6mm diameter x 240mm long stainless steel shaft with 3m long neoprene hose. Type K thermocouple
Home Gas, HVAC & Plumbing Flue Gas Analysers