OMRON欧姆龙 E3JM-R4M4 机械传动-产品快照
- 品牌:
- OMRON
- 型号:
- E3JM-R4M4
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
北京市京浙电子技术有限公司 | 010-82665209 | |
东莞市科威自动化设备有限公司 | 4006699083 | |
东莞市欧能自动化设备有限公司 | 18680502757 | |
东莞市中昊自动化科技有限公司 | 0769-22882481 | 传感器解决方案 |
东莞运通工业器材有限公司 | 0769-28056288 | |
福州倍德福工业自动化设备有限公司 | 0591-83500620 | |
福州福大自动化科技有限公司 | 0591-28482265 | |
广州科韵商贸发展有限公司 | 020-87508653 | |
广州市振欣自动化系统有限公司 | 020-85267788 | |
买道传感科技(上海)有限公司 | 021-51872140 | |
上海行之达电子有限公司 | 021-66988928 | |
上海欧龙翰邦自动化系统有限公司 | 021-32515208 | |
深圳市华光行电工器材有限公司 | ||
深圳市明琪宏科技有限公司 | 0755-82873757 | |
苏州工品汇信息科技有限公司 | 4000496999 |
产品介绍
OMRON欧姆龙 E3JM-R4M4 机械传动
Ac/DC Power-Source Free Type Photoelectronic Switch E3Jm E3JM-R4M4
OMRON
Material (lens) Methacrylic resin Withstand Voltage AC2000V 50/60Hz 1min Output Relay Detection Distance (m) 4 (when using E39-R1 type) Detection Distance (mm) - Differential Movement - Materials (cover) Polycarbonate Materials (mounting bracket) Iron Light Sources (projection of light wavelength) Red light emitting diode (660nm) Response Time Operation / reset: each 30ms or less Ambient Temperature (Degree C) During operation: -25 -+55 During storage: -30 - +70 (not during times of condensation or freezing) Detection Distance 4m (when E39-R1 form is used) Detection Method Regressive reflective type (with M.S.R function) Supply Voltage Less than DC12-240V+/-10% Ripple (p-p) 10%, AC24-240V+/-10% 50/60Hz Accessories Mounting bracket (with screws), nut, terminal protection cover, nut with cord attached, reflector Control Output 1c contact point less than AC250V 3A (cosphi=1), more than DC5V 10mA Incident light: ON / blackout: ON switch system Caution This product is manufactured in Japanese standards. Please check the specification before you order., Sensor with timer function (FORM E3JM-XXX4T)cannot disable timer function. Material (case) ABS Protection Structure IEC standard IP66 Sensitivity Adjustment - Functions - Standard Detective Object (mm) Opaque body more than phi75 Connection Method Terminal-block type Power Consumption Below DC2W, below AC2W Insulation Resistance (Mohm) 20 or more (with DC500V megger) Angle of Beam Spread (degree) 1 - 5 Ambient Humidity (% RH) At the time of operation: 45-85, time of storage: 35-95 (not in cases of freezing or condensation) Lifespan Relay light emission: Mechanically over 50 million times (opening and closing frequency is over 180000 times per hour), electronically over 10 million times (Opening and closing frequency is 1800 times per hour) Impact Resistance (Malfunction) 100m/s 2 X, Y, Z for all 3 directions Vibration Resistance (malfunction) 10 to 55Hz double amplitutde 1.5mm X,Y, and Z each direction 2 hours Timer Functions - Using Periphery illuminanation (Lx) Acceptance surface intensity of illumination Incandescence lamp: 3000 or less Impact Resistance 500m/s 2 X, Y, Z, all directions 3 times Vibration Resistance 10 to 55Hz double amplitutde 1.5mm X,Y, and Z each direction 2 hours
FA and Mechanical Parts Controlled Equipments Omron