OMRON欧姆龙 S8VS-12024 机械传动-产品快照
- 品牌:
- OMRON
- 型号:
- S8VS-12024
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
北京市京浙电子技术有限公司 | 010-82665209 | |
东莞市科威自动化设备有限公司 | 4006699083 | |
东莞市欧能自动化设备有限公司 | 18680502757 | |
东莞市中昊自动化科技有限公司 | 0769-22882481 | 传感器解决方案 |
东莞运通工业器材有限公司 | 0769-28056288 | |
福州倍德福工业自动化设备有限公司 | 0591-83500620 | |
福州福大自动化科技有限公司 | 0591-28482265 | |
广州科韵商贸发展有限公司 | 020-87508653 | |
广州市振欣自动化系统有限公司 | 020-85267788 | |
买道传感科技(上海)有限公司 | 021-51872140 | |
上海行之达电子有限公司 | 021-66988928 | |
上海欧龙翰邦自动化系统有限公司 | 021-32515208 | |
深圳市华光行电工器材有限公司 | ||
深圳市明琪宏科技有限公司 | 0755-82873757 | |
苏州工品汇信息科技有限公司 | 4000496999 |
产品介绍
OMRON欧姆龙 S8VS-12024 机械传动
Switching Power Supply S8VS S8VS-12024
OMRON
Caution This product is manufactured in Japanese standards. Please check the specification before you order. higher Harmonics Current Regulation EN61000-3-2 compatibility Efficiency 80% or more Output Indicator Available(color: green) Output Voltage (V) 24 Operating Ambient Temperature (deg C) -10 - 60 Weight (g) 550 or less Capacity (W) 120 Mounting Direction Standard installation Storage Temperature (DegreeC) -25 - +65 Impact Resistance (m/s2) 150 (no abnormalities when all six directions were taken 3 times each) Insulation Resistance (Mohm) MORE THAN 100 (BULK OUTPUT, ALARM OUTPUT BULK) (BULK INPUT GROUND [EARTH]) WHILE AT DC500V Output Current Display Not available Functions Series operation: possible (for up to 2 units, an external installation diode is needed) Parallel Operation: Not allowed Low voltage detection display: none Inrush Current (A) during 100V input: below 25A during 200V input: below 50A (d5 degrees, cold start) Safety Standards UL60950-1, UL:UL508 (Listing) cUR:CSA C22.2 No.107.1 cUR:CSA C22.2 No.60950-1 EN/VDE:EN50178 (VDE0160), EN60950-1 (= VDE0805 Teil1) Korea S Mark Starting Time (min) less than1000 (by rated input and output) Ambient Humidity 25-85% (Saves between 25 and 90% humidity) Alarm Output Sink (emitter COM) Vibration Resistance Are normal each in 2 h of piece amplitude of 10-55 Hz 0.375 mm 3 directions. Load Changes 1.5% or less (by a rated input and 0 to 100% load) Withstand Voltage AC3.0kV 1min between(batch input)and (batch output)(detection current of 20mA) AC2.0kV 1min between(batch input)and (batch output)(detection current of 20mA) AC1.0kV 1min between(batch output, alarm batch output) and (ground [earth[/FG)) (detection current of 30mA) AC3.0kV 1min (output package) and between (an output package, an alarm output package) (20 mA of detection current) Type Standard type Input Frequency (Hz) 50/60Hz(47 - 63Hz) Output Current (A) 5 Input Voltage (V) AC100 - 240 Installation Method Corresponds to DIN rail attachment Power Factor 0.95 or more Temperature Fluctuation 0.05%/deg C or less Terminal Block Screw terminal block Output Voltage Adjustable Range (%) -10-+15 (at V.AD) Radiated Interference Field Intensity EN55011Group1 ClassB conformity Outer Dimensions (Width W x Height H x Depth D) (mm) 50x115x121.3 Peak Hold Current Display Not available Output Ripple Noise Voltage Below 2.0% (p-p) (rated input and output) Output Voltage Display Not available Leakage Current (mA) During 100V input: less than .5 200V input: 1 or less Over-Voltage Protection Present (To automatically reset, turn off the power, wait for 3 minutes, then turn back on the power) Disturbance Voltage EN55011Group1 ClassB conformity, FCC class A conformity Overcurrent Protection 105 to 160% Rated input voltage, Reverse L shape doop, auto recovery Input Curret (A) At a 100V input : less than 1.9 at 200V input: below 1.1 Replacement Not available Under Voltage Detection Output Not available Output Holding Time 20 ms or more (by rated input and output) Input Variation Influence 0.5% or less (input AC85 - 264V and 100% load)
FA and Mechanical Parts Controlled Equipments Omron