OMRON欧姆龙 D2MC-5EL 机械传动-产品快照
- 品牌:
- OMRON
- 型号:
- D2MC-5EL
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
北京市京浙电子技术有限公司 | 010-82665209 | |
东莞市科威自动化设备有限公司 | 4006699083 | |
东莞市欧能自动化设备有限公司 | 18680502757 | |
东莞市中昊自动化科技有限公司 | 0769-22882481 | 传感器解决方案 |
东莞运通工业器材有限公司 | 0769-28056288 | |
福州倍德福工业自动化设备有限公司 | 0591-83500620 | |
福州福大自动化科技有限公司 | 0591-28482265 | |
广州科韵商贸发展有限公司 | 020-87508653 | |
广州市振欣自动化系统有限公司 | 020-85267788 | |
买道传感科技(上海)有限公司 | 021-51872140 | |
上海行之达电子有限公司 | 021-66988928 | |
上海欧龙翰邦自动化系统有限公司 | 021-32515208 | |
深圳市华光行电工器材有限公司 | ||
深圳市明琪宏科技有限公司 | 0755-82873757 | |
苏州工品汇信息科技有限公司 | 4000496999 |
产品介绍
OMRON欧姆龙 D2MC-5EL 机械传动
Low Torque Basic Switch D2MC D2MC-5EL
OMRON
Caution This product is manufactured in Japanese standards. Please check the specification before you order. Electrical Durability 100,000 times or more (30 times / min) Vibration Resistance (malfunction) (Contact opening or closing within 1ms) 10 to 55Hz 1.5mm double amplitude frequency Contact Interval 0.5mm (standard value) Rating AC125V 5A Weight (g) About 10 Movement of Differential (MD) Minimum 3 degree Contact Resistance (mohm) 20 or less (initial value) Contact Materials Silver alloy Direction of Rotation (Actuator) counter-clockwise direction Operating Ambient Temperature (deg C) (Icing or no condensation) RH below -25 to +85 60% Inrush Current (A) (Normally closed) up to 15, (always open) up to 7 Withstand Voltage Ground between AC600V 50/60Hz 1min charging metal parts, non-current-carrying metal parts between each terminal: the electrode terminal between non-current-carrying metal parts AC1500V 50/60Hz 1min between each terminal and Specification Torque required for operation (OTq): maximum 0.50mNm Torque of return (RTq): minimum 0.06mNm RoHS Directive Fit Mechanical Durability 10 million times or more (60 times / min) Protection Structure IEC IP40 Allowable Operating Speed 1 degree to 360 degree / s Minimum Adaptable Load DC5V 160mA Ambient Humidity Less than 85% RH (at +5 to +35 deg C) Movement after Operation (OT) Minimum 17 degree PT Movement until Operation Maximum 21 degree Contact Specification Rivet Impact Resistance Up to 1000m / s 2 sup> (Contact opening or closing within 1ms) Insulation Resistance (Mohm) 100 or more (by DC500V insulation resistance tester) Allowable Operating Frequency (In the case of 0.5mN ? m) 60 times / min: Mechanical: 240 times / min electrical Impact Resistance (Malfunction) Up to 100m / s 2 sup> (Contact opening or closing within 1ms)
FA and Mechanical Parts Controlled Equipments Omron