RBAPMWV4A12V - Electro-proportional relief valve - pilot capacity

Sun Hydraulics

This 2-port, pilot-stage, direct-acting relief cartridge is an electro-proportionally controlled, pressure regulating valve. The proportional control allows for infinite, step-less adjustability within the selected pressure range. When the pressure at port 1 (inlet) is sufficient to overcome the solenoid forces, as determined by the analog input signal, the poppet lifts and allows flow from port 1 to port 2 (outlet). This pilot control cartridge utilizes the T-8A cavity so it can be used in conjunction with Sun's main stage, pressure control elements. Varying the analog input signal to the proportional solenoid provides a step-less control of pressure. This electro-proportional cartridge utilizes the Sun T-8A, 2-port cavity making it the ideal choice to use in conjunction with Sun's main stage cartridges. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function. Note: All 2-port pilot stage control cartridges utilize the same cavity and are physically interchangeable. Functionality is the only consideration. All pressure ranges will drop to a setting of 0 with no analog input signal. The pressure ranges indicate the valve's area of acceptable performance. The L control (Manual Override - Adjustable) allows one to manually adjust the valve in case of an electrical failure. The L control also allows one to offset the pressure range. For instance, if an A range valve is mechanically offset to a setting of 1500 psi (105 bar), the new maximum will be 4500 psi (310 bar). The 'E' manual control assembly has a mechanical life expectancy of approximately 7,000 cycles. Damped construction provides stable operation over a wide range of operating conditions. Note: Models equipped with an 'M' control do not incorporate the dampening orifice in the solenoid armature. The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees. Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals. Capable of operating with pressures up to 5000 psi. Low leakage levels in the closed position. (Reseat occurs at 85% of cracking pressure.) Coils are interchangeable with Sun's other full flow, solenoid operated valves and can be mounted on the tube in either direction. For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz. NOTE: There is no upper limit to the pressure setting when using the M control. The more force you exert on the manual override, the higher the resulting pressure. High pilot capacity allows for operation of larger size main stage elements. Note: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value. Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations. Cavity T-8A Series P Capacity .25 gpm1 L/min. Maximum Operating Pressure 5000 psi350 bar Maximum Valve Leakage at Reseat 1.5 in³/min.25 cc/min. Manual Override Force Requirement 10 lbs/1000 psi @ Port 166 N/100 bar @ Port 1 Reseat >85% of setting>85% of setting Solenoid Tube Diameter .75 in.19 mm Valve Hex Size 7/8 in.22,2 mm Valve Installation Torque 20 - 25 lbf ft27 - 33 Nm Model Weight (with coil) 1.00 lb0,45 kg Seal kit - Cartridge Viton: 990-208-006 Seal and nut kit - Coil Viton: 990-770-006Viton: 990-770-006 Show FAQ Direct acting or pilot operated - what do I use? Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust. How do I get a kick-down relief to reset? The kick-down relief acts much like a circuit breaker. When the pressure at the inlet (port 1) of the relief valve rises to the setting, the valve pops open and drops the pressure down to 100 psi or so. The valve stays open until flow through it stops. Shutting off the supply of oil will reset the valve; reversing pressure on the valve is a positive way of resetting it. Where would I use a kick-down relief? One graphic example is on a portable grain auger for silos. When the farmer gets caught in the auger the kick-down relief trips and allows him to escape. How big is a drop of hydraulic oil? There are exactly 250 Sun drops in a cubic inch or 15 in a cc. What are the tolerances on pressure settings for Sun's pressure control valves? Pressure setting tolerances are listed in our Performance Data page. A link to this page can also be found in the Additional Resources tab of the applicable product page. Can I use a kick-down relief for my system relief? Maybe not. We build in a good amount of overlap in the kick-down reliefs to prevent false tripping. This means they are not as fast as our standard pilot-operated reliefs. A direct-acting relief valve set just above the kick-down relief valve would be good insurance. Additional Resources Pilot Operated, Balanced Poppet Relief Valves Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses Sun Offers Zinc-Nickel Plating for Corrosion Resistance Sun Cartridges with EPDM Seals 'Soft' Relief Eliminates Pressure Spikes Pilot-Operated, Balanced Poppet, Anti Shock Reliefs Configure Your Bluetooth Embedded Amplifier with AmpSet Blue™ Sun Introduces 'Hybrid' Valves Tri-Grip Handknob Now Offered From Sun as a Standard Control Option Sun Expands Corrosion-Resistant Solutions CavitySaver multi-function valves deliver single-cartridge solutions Electro-Proportional Basics Explained CE/TÜV Certified Pressure Relief Valves Weatherized Solenoid Valves for Harsh Environments QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool Pressure Relief and Regulating Cartridge Valve Technical Tips Pressure Relief and Regulating Valves Proportional Amplifiers and Ancillary Products Manufacturing Sun Cartridge Cavities Solenoid Coils for Switching and Proportional Valves Electro-Proportional Cartridge Valves Performance Data Sun Model Code Explanation; 999-901-334 Units of Measure, Settings, and Conversions Electro-Proportional Terms and Definitions Cartridges: Materials of Construction Cavity Information (S-171) and Tooling Sun's Floating Style Screw-In Cartridge Fluid and Temperature Recommendations Notes: Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances. Related Files Download Download Download Download Download Download Download

Home / Sun Hydraulics - RBAPMWV4A12V - Electro-proportional relief valve - pilot capacity

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。