Sun Hydraulics  PRDLLBE72499 减压阀

Sun Hydraulics PRDLLBE72499 减压阀-产品快照

品牌:
Sun Hydraulics
型号:
PRDLLBE72499

* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.


供应商名称 电话 备注
上海萨弗工控设备有限公司 021-51095192
上海伦萨液压设备有限公司 021-69008526
升旭液压系统有限公司 021-51162862
橡达油压机械(上海)有限公司

Sun Hydraulics供应商或现货商入驻,请点击>>

产品介绍

Sun Hydraulics PRDLLBE72499 减压阀

PRDLLBE72499 - Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition

Sun Hydraulics

This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the relieving mode. Energizing the coil connects port 2 to port 1. Increasing the current to the coil will proportionally increase the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is open in the transition from reducing to relieving. It provides good pressure control and dynamic response. Optional full manual control is available. Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar). Maximum pressure at port 3 should be limited to 3000 psi (210 bar). Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions. Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit. The transition from reducing to relieving is slightly open. The result is very good pressure control with oil consumption of about 0.1 gpm (0,4 L/min.). For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz. NOTE: There is no upper limit to the pressure setting when using the M control. The more force you exert on the manual override, the higher the resulting pressure. The 'E' manual control assembly has a mechanical life expectancy of approximately 7,000 cycles. The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees. Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals. All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges. Uses for the 'L' manual screw adjustment include: emergency valve setting during power failure or alternatively boosting the valve setting With the 'L' adjustment screw, all ranges are factory set at zero (adjustment screw fully backed out). With the coil de-energized, clockwise adjustment of the screw will increase the spring bias load up to the maximum setting for that range. With the coil energized, any mechanical pressure setting is directly additive to the coil induced value. Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations. Cavity T-11A Series 1 Capacity 5 gpm20 L/min. Maximum Operating Pressure 5000 psi350 bar Maximum Valve Leakage at 110 SUS (24 cSt) 20 in³/min.330 cc/min. Adjustment - Number of Clockwise Turns to Increase Setting 55 Solenoid Tube Diameter .75 in.19 mm Valve Hex Size 7/8 in.22,2 mm Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm Adjustment Screw Internal Hex Size 5/32 in.4 mm Locknut Hex Size 9/16 in.15 mm Locknut Torque 80 - 90 lbf in.9 - 10 Nm Model Weight (with coil) 1.20 lb0,55 kg Seal kit - Cartridge Viton: 990-511-006 Seal and nut kit - Coil Viton: 990-770-006Viton: 990-770-006 Show FAQ I need a reducer on B. Can I connect the drain to A? Yes. If you look in the sandwich section you will see that we offer many such packages. When you are pressurizing B, A is connected to tank, allowing the reducer to do its job. When you reverse, the drain or tank port of the reducer is pressurized by A. This increases the setting of the reducer and helps keep the reducer open in the reverse flow direction. What do you mean by maximum differential? Our reducing valves are outside-in valves; the supply pressure on the outside of the working parts is higher than the inside. At some pressure differential, the outside (sleeve) will close in on the piston and cause the valve to stick. A D range is adjustable from 25 to 800 psi with a maximum differential of 2000 psi. This means you could set the valve at 600 psi and expect it to work correctly with a supply pressure of 2600 psi. The valve may work at higher differentials, but we do not recommend it. The W and C ranges are tested over their entire range with an inlet pressure of 5000 psi. All direct-acting valves are tested with an inlet pressure of 5000 psi. Will your reducing/relieving valve relieve my pump to tank? No. A reducing/relieving valve throttles a supply of oil to maintain a set pressure in a secondary circuit. The valve is open until the secondary or downstream pressure rises to the setting of the valve at which time it starts to close to limit the pressure. If the secondary or downstream pressure is caused to go above the setting, the valve shifts into relieving mode and throttles the secondary circuit back to tank to prevent over-pressure. At no time can the valve connect the supply to tank. How big is a drop of hydraulic oil? There are exactly 250 Sun drops in a cubic inch or 15 in a cc. Direct acting or pilot operated - what do I use? Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust. Can I back flow through a reducing valve from port 1 to port 2? Yes. A reducing or reducing/relieving valve is normally open. If the pressure in the secondary circuit is less than the setting, it will be open.2 caveats: (1) If the valve is in the reducing mode and you suddenly reverse the flow, the valve will not have time to open and will shift into relieving mode or (2) If the back flow generates a pressure drop through the valve that exceeds the setting, the valve will shift into the relieving mode.When in doubt, use a reverse flow check. What are the tolerances on pressure settings for Sun's pressure control valves? Pressure setting tolerances are listed in our Performance Data page. A link to this page can also be found in the Additional Resources tab of the applicable product page. Additional Resources Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool Electro-Proportional Basics Explained Sun Offers Zinc-Nickel Plating for Corrosion Resistance Sun Expands Corrosion-Resistant Solutions Sun Cartridges with EPDM Seals Weatherized Solenoid Valves for Harsh Environments Configure Your Bluetooth Embedded Amplifier with AmpSet Blue™ Reducing and Reducing/Relieving Valves Proportional Amplifiers and Ancillary Products Manufacturing Sun Cartridge Cavities Solenoid Coils for Switching and Proportional Valves Electro-Proportional Cartridge Valves Performance Data Cartridges: Materials of Construction Units of Measure, Settings, and Conversions Electro-Proportional Terms and Definitions Cavity Information (S-171) and Tooling Sun's Floating Style Screw-In Cartridge Fluid and Temperature Recommendations Sun Model Code Explanation; 999-901-334 Notes: Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances. Related Files Download Download Download

Home / Sun Hydraulics - PRDLLBE72499 - Electro-proportional, direct-acting, pressure reducing/relieving valve with open transition

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。