Sun Hydraulics PBJF8WV

PBJF8WV - Pilot operated, pressure reducing main stage with drilled piston orifice and integral T-8A control cavity

Sun Hydraulics

This valve is a normally open modulating element that incorporates an integral pilot control cavity. The pilot control cavity will accept any T-8A pressure control cartridge. The valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1. The pilot cartridge's setting determines the difference in pressure between reduced pressure (port 1) and the drain (port 3). These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications. All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges. Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit. Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes. Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis. Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar). Maximum inlet pressure is determined by the bias spring. The D spring is tested with 2000 psi (140 bar) maximum differential pressure and the W spring is tested with 5000 psi (350 bar) maximum inlet pressure. NOTE: With the -8 control option, the main stage valve should first be installed to the correct torque value. The T-8A pilot control valve should then be installed into the main stage valve to its required torque value. The -8 control option allows the pilot control valve to be incorporated directly into the end of the relief cartridge via the T-8A cavity. These pilot control cartridges are sold separately and include electro-proportional, solenoid, air pilot, and hydraulic pilot operation. See Pilot Control Cartridges. Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations. Cavity T-19A Series 4 Capacity 80 gpm320 L/min. Factory Pressure Settings Established at blocked control port (dead headed)blocked control port (dead headed) Maximum Operating Pressure 5000 psi350 bar Control Pilot Flow 15 - 20 in³/min.0,25 - 0,33 L/min. Pilot Control Cavity T-8AT-8A Valve Hex Size 1 5/8 in.41,3 mm Valve Installation Torque 350 - 375 lbf ft474 - 508 Nm Model Weight 2.90 lb1,30 kg Seal kit - Cartridge Viton: 990-019-006 Show FAQ Can I back flow through a reducing valve from port 1 to port 2? Yes. A reducing or reducing/relieving valve is normally open. If the pressure in the secondary circuit is less than the setting, it will be open.2 caveats: (1) If the valve is in the reducing mode and you suddenly reverse the flow, the valve will not have time to open and will shift into relieving mode or (2) If the back flow generates a pressure drop through the valve that exceeds the setting, the valve will shift into the relieving mode.When in doubt, use a reverse flow check. I need a reducer on B. Can I connect the drain to A? Yes. If you look in the sandwich section you will see that we offer many such packages. When you are pressurizing B, A is connected to tank, allowing the reducer to do its job. When you reverse, the drain or tank port of the reducer is pressurized by A. This increases the setting of the reducer and helps keep the reducer open in the reverse flow direction. What do you mean by maximum differential? Our reducing valves are outside-in valves; the supply pressure on the outside of the working parts is higher than the inside. At some pressure differential, the outside (sleeve) will close in on the piston and cause the valve to stick. A D range is adjustable from 25 to 800 psi with a maximum differential of 2000 psi. This means you could set the valve at 600 psi and expect it to work correctly with a supply pressure of 2600 psi. The valve may work at higher differentials, but we do not recommend it. The W and C ranges are tested over their entire range with an inlet pressure of 5000 psi. All direct-acting valves are tested with an inlet pressure of 5000 psi. Direct acting or pilot operated - what do I use? Direct-acting valves are used to prevent over pressure, and pilot-operated valves are used to regulate pressure. If you are unsure, use a direct-acting valve. Sun's direct acting valves are very fast, dirt tolerant, stable, and robust. Sun's pilot-operated valves are moderately fast, they have a low pressure rise vs. flow curve, and they are easy to adjust. How big is a drop of hydraulic oil? There are exactly 250 Sun drops in a cubic inch or 15 in a cc. What are the tolerances on pressure settings for Sun's pressure control valves? Pressure setting tolerances are listed in our Performance Data page. A link to this page can also be found in the Additional Resources tab of the applicable product page. Additional Resources Weatherized Solenoid Valves for Harsh Environments Configure Your Bluetooth Embedded Amplifier with AmpSet Blue™ Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool Electro-Proportional Basics Explained Sun Offers Zinc-Nickel Plating for Corrosion Resistance Sun Expands Corrosion-Resistant Solutions Sun Cartridges with EPDM Seals Solenoid Coils for Switching and Proportional Valves Reducing and Reducing/Relieving Valves Proportional Amplifiers and Ancillary Products Manufacturing Sun Cartridge Cavities Sun's Floating Style Screw-In Cartridge Fluid and Temperature Recommendations Sun Model Code Explanation; 999-901-334 Performance Data Cartridges: Materials of Construction Units of Measure, Settings, and Conversions Electro-Proportional Terms and Definitions Cavity Information (S-171) and Tooling Related Files Download Download Download

Home / Sun Hydraulics - PBJF8WV - Pilot operated, pressure reducing main stage with drilled piston orifice and integral T-8A control cavity

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。