Sun Hydraulics  FKBALCV 节流阀

Sun Hydraulics FKBALCV 节流阀-产品快照

品牌:
Sun Hydraulics
型号:
FKBALCV

* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.


供应商名称 电话 备注
上海萨弗工控设备有限公司 021-51095192
上海伦萨液压设备有限公司 021-69008526
升旭液压系统有限公司 021-51162862
橡达油压机械(上海)有限公司

Sun Hydraulics供应商或现货商入驻,请点击>>

产品介绍

Sun Hydraulics FKBALCV 节流阀

FKBALCV - 2-way, pilot shifted, proportional throttle

Sun Hydraulics

This valve is a 2-way, 2 position, proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1 creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes. Pressure at port 4 directly opposes pressure at port 1. An optional tuning adjustment (L control) is offered to vary the pilot pressure required to control flow. The tuning adjustment provides a means to manually increase or decrease flow at a given pilot pressure. The adjustment range is 50 - 450 psi (3,5 - 30 bar), 100 psi (7 bar) Standard Setting. These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit. The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information. Ports 1 and 4 should be limited to 500 psi (35 bar). Pressure at port 4 directly opposes pressure at port 1. Accurate pressure compensated control requires that a constant pressure differential be maintained across the valve. Cartridges with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals. Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations. Cavity T-21A Series 1 Capacity 5 gpm20 L/min. Maximum Operating Pressure 5000 psi350 bar Maximum Valve Leakage at 110 SUS (24 cSt) 2 in³/min.@1000 psi30 cc/min.@70 bar Pilot Volume Displacement .02 in³0,33 cc Minimum Pilot Pressure to Operate 100 psi7 bar Hysteresis ± 2 %± 2 % Adjustment - Number of Clockwise Turns to Increase Setting 55 Valve Hex Size 7/8 in.22,2 mm Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm Adjustment Screw Internal Hex Size 5/32 in.4 mm Locknut Hex Size 9/16 in.15 mm Locknut Torque 80 - 90 lbf in.9 - 10 Nm Model Weight .30 lb0,15 kg Seal kit - Cartridge Viton: 990-021-006 Show FAQ What happens if I block the bypass port on a priority flow control? The valve acts as a 2 port restrictive flow control. How big is a drop of hydraulic oil? There are exactly 250 Sun drops in a cubic inch or 15 in a cc. How accurate are Sun's flow controls? We claim +/- 10%. We set to +/- 5% in production testing to allow for differences in customers' conditions. If you want accuracy, stay in the bottom 2/3rds of the range. Our 12 gpm (45 L/min.) flow controls are quite flat at 9 gpm (34 L/min.) and dead flat below 6 gpm (23 L/min.), until you get to the bottom of the range. Below about .25 gpm (1 L/min.), spool leakage and orifice conditions start to limit accuracy. I have a heat problem, will Sun's priority flow control help? I am afraid not. Unless you are overflowing your current valve and correctly size ours, you are not likely to notice any improvement. Priority flow controls are not efficient devices. They are an easy way to get more than 1 source of oil from 1 pump but they can generate a lot of heat. Try to size your actuators so the pressures are similar on both the priority and the bypass circuits. If you can't do that, try to have the lower flow leg be the lower pressure. The pump pressure is determined by whichever leg is higher and if there is flow that is taking a pressure drop that is not doing work it is creating heat. What happens if I block the control flow (priority) port? All flow is blocked, hence the term priority. The priority flow has to be satisfied. What is the compensating pressure of Sun's flow controls? The spring force in our flow controls equates to about 100 psi (7 bar). This is high enough to give the valves acceptable capacity (not really) and not too high for proper circuit operation. 100 psi (7 bar) is the spring force; at the upper end of the flow control's range, the drop through the valve will be as high as 250 psi (17 bar) before it starts modulating. What is the pressure drop through a flow control? In a meter-in flow control circuit if the pump is set at 3000 psi and the load is 2000 psi the drop through the flow control is 1000 psi. In a meter-out circuit with the load at 2000 psi the drop through the flow control is 2000 psi. Related Files Technical TipsTechnical Tips for Proportional Amplifiers and Ancillary Products (2.06 MB) Technical Tips for Manufacturing Sun Cartridge Cavities (522.27 KB) Technical Tips for Solenoid Coils for Switching and Proportional (975.2 KB) Electro-Proportional Terms and Definitions (1.08 MB) Sun's Floating Style Screw-In Cartridge (719.9 KB) Sun Model Code Explanation; 999-901-334 (343.9 KB)

Home / Sun Hydraulics - FKBALCV - 2-way, pilot shifted, proportional throttle

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。