Sun Hydraulics FQGAXBN/AP 流量阀-产品快照
- 品牌:
- Sun Hydraulics
- 型号:
- FQGAXBN/AP
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
上海萨弗工控设备有限公司 | 021-51095192 | |
上海伦萨液压设备有限公司 | 021-69008526 | |
升旭液压系统有限公司 | 021-51162862 | |
橡达油压机械(上海)有限公司 |
产品介绍
Sun Hydraulics FQGAXBN/AP 流量阀
FQGAXBN/AP - Fixed orifice, flow fuse valve
Sun Hydraulics
Flow fuse cartridges are used to maintain the position of a hydraulic actuator in the event of a hose or line break. The valve allows flow to and from the actuator but closes instantly if flow from the actuator exceeds the setting of the valve. NOTE: Because the valve responds so rapidly, it is sensitive to any transient flow above the valve setting. Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting. Valve closes when flow from port 1 to port 2 exceeds the setting of the valve. Valve resets when pressures at port 1 and port 2 are equal. Flow setting should be at least 25% above maximum normal system flow. Customer must specify flow when ordering valve. These are spool type valves, therefore there is leakage. Some actuator drift may occur. Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations. Cavity T-16A Series 3 Capacity 25 gpm95 L/min. Maximum Operating Pressure 5000 psi350 bar Maximum Valve Leakage at 110 SUS (24 cSt) 4 in³/min.@1000 psi65 cc/min.@70 bar Valve Hex Size 1 1/4 in.31,8 mm Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm Model Weight .70 lb0,30 kg Seal kit - Cartridge Viton: 990-016-006 Show FAQ How big is a drop of hydraulic oil? There are exactly 250 Sun drops in a cubic inch or 15 in a cc. Can I use a flow fuse to prevent the loss of oil? NO! Flow fuses are meant to prevent the uncontrolled movement of an actuator in case of hose failure. Can I use a flow fuse to provide fire protection? NO! Flow fuses are meant to prevent the uncontrolled movement of an actuator in case of hose failure. To avoid false tripping they must be set above the typical system flow, usually 50% above. On a 4 gpm (15 L/min.) circuit the flow fuse may need to be set at 6 gpm (23 L/min.) to avoid false tripping. Hoses do not normally fail totally, they spring a leak. If the hose springs a 5.5 gpm (21 L/min.) leak the flow fuse will not trip. 5.5 gpm (21 L/min.) of hydraulic fluid will feed a fire that would heat a small town in Ohio (Denmark) in January! How should I choose the setting of a flow fuse? It is very, very difficult to predict the transient flows in a system. We say at least 25% above maximum normal system flow and should say 50%. Don’t back yourself into a corner by sizing a flow fuse at the top end of its range unless you can test it. If you have an FQCA in a 4 gpm (15 L/min.) circuit, set at 6 gpm (23 L/min.) and it false trips, you are out of luck. Select an FQEA and leave yourself some room for tuning. Every time I try to lower my load the flow fuse trips. What's wrong? What's wrong is that every time you start to lower your load, you get a flow transient that exceeds the setting of the flow fuse and trips it. Sun's flow fuses are very consistent and very fast. Related Files Technical TipsTechnical Tips for Manufacturing Sun Cartridge Cavities (522.27 KB) Technical Tips for Circuit Savers (466.24 KB) Sun's Floating Style Screw-In Cartridge (719.9 KB) Sun Model Code Explanation; 999-901-334 (343.9 KB)
Home / Sun Hydraulics - FQGAXBN/AP - Fixed orifice, flow fuse valve