Danfoss丹佛斯 178B8577 变频器-产品快照
- 品牌:
- Danfoss
- 型号:
- 178B8577
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
广州帕亚科技有限公司 | 020-37667990 | |
北京圣泰洋电器有限公司 | 010-61581431 | 工业自动化 |
深圳欧普瑞科技有限公司 | 0775-82542063 | 工业自动化 |
上海阔为贸易有限公司 | 021-64136978 | 工业自动化 |
杭州合擎电气技术有限公司 | 0571-86032789 | 工业自动化 |
上海华丰工业控制技术工程有限公司 | 021-56984579 | 动力系统 |
丹福国际贸易(深圳)有限公司 | 021-64681930 | 动力系统 |
北京佰利安科技有限公司 | 010-82800390 | 动力系统 |
广州市康达斯机电设备有限公司 | 020-83852320 | 商业制冷 |
深圳恒信冷冻器材有限公司 | 0755-82412186 | 商业制冷 |
上海华光制冷设备有限公司 | 021-63643894 | 商业制冷 |
北京汇嘉制冷设备有限公司 | 010-64477130 | 商业制冷 |
丹佛斯(天津)有限公司 | 022-82126400 | |
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
厦门南丽杰工业设备有限公司 | 0592-5685601 |
产品介绍
Danfoss丹佛斯 178B8577 变频器
178B8577 | Danfoss Vlt 2800 0.55kw Inverter Drive 1.7a, Three Phase With A 380...480v Ac Supply Vlt2805pt4b20sbr0dbf00a00c1
Danfoss
Description Danfoss 178B8577 - Compact General Purpose Inverter Drives Advanced and versatile, the VLT 2800 is an ideal general purpose inverter drive. 178B8577 is a Three Phase, 1.7A, 0.55 kW inverter drive with a 380...480V AC supply. These modular AC drives consist of a power module and a control module and mountable side-by-side saving you installation space and money. For the low power market, the VLT 2800 range is ideal. Smart and safe to benefit your application Product safety A number of safety features are included such as 100% earth fault protection and mains transient protection. Other safety features include galvanic isolation and both switching on input and output. Intelligent 178B8577 enjoys a number of features that make it an intelligent part of your system. Bus communication, precise stop, pump and wobble functions make it suitable for many industrial applications. Bus communications Bus communications including DeviceNet, Profibus DP, Modbus RTU and Metasys allow your 0.55 kW inverter drive to communicate with other devices in your system. Applications for your Danfoss 0.55 kW inverter drive The whole VLT 2800 series is designed for stable operation in industrial environments. You can use your 0.55 kW AC drives in many applications including: Pump Fan Conveyor Extruder Mixer Wrapper Gantry crane (small loads) Cutting Rotor spinning Winder Wobble Dedication to your application The VLT 2800 family has a selection of additional features that are designed to optimise operation and protection of system components for typical applications. Built-in wobble function On a textile winder the wobble function is used for the traverse function. {part num} operates a motor, which turns a grooved drum. During winding, the grooved drum places the thread in a diamond pattern in the correct position on the bobbin. When the traverse drum operates at a constant speed, the thread crosses at the same position for each pass, which results in loose and less compact winding on the bobbin. Precise stop On a conventional inverter drive, digital inputs are scanned periodically - this initiates the Stop command. With a periodical scan, uneven delays can be caused as the drive scans all other parts of the program. VLT 2800 solves this problem as the Stop command is an interrupt rather than part of the scan, typically reducing deviation from ±10 mm to ±1 mm Counter precise stop After the start signal is received the VLT 2800 operates until the number of of pulses is seen at terminal 33. A Stop signal is generated and the normal stop ramp is used. The counter stop signal is then re-armed and ready again for a new start command. The pulse input is designed to handle 24 V push-pull pulses from an encoder with up to 1024 ppr. The maximum pulse rate is 67,600 Hz. Specifications Mains supply Supply voltage 380...480V AC Supply frequency 50/60 Hz Displacement power factor (cos φ) near unity (>0.98) Switching on input supply 1-2 time/min Output data Output voltage 0-100% of supply voltage Output frequency 0-200 Hz (VVC+ mode), 0-400 Hz (U/f mode) Switching on output Unlimited Ramp times 1-3600 sec Closed loop 0-132 Hz Digital inputs For start/stop, reset, thermistor, etc. 2 Logic PNP or NPN Voltage level 0-24 VDC Pulse inputs Number of pulse inputs 2 Voltage level 0-24 VDC (PNP positive logic) Pulse input accuracy (0.1-110 kHz) Digital output Number of digital outputs 1 Analogue output Programmable analogue outputs 1 Current range 0/4 to 20 mA Relay outputs Number of relay outputs 1 Fieldbus communication RS485 Ambient temperature 50°C Specification Alternative Partnumber VLT2805PT4B20SBR0DBF00A00C1 Product Status Current Range VLT 2800 Range type Variable Speed Drive Communications Options N/A No Analog Inputs 2 No Digital Outputs 1 Relay Outputs 1 PTC/KTY Input N/A Pulse Output N/A NEMA N/A Logic Positive, Negative Protection N/A Width (mm) 75.0000 Height (mm) 200.0000 Weight (kg) N/A Constant Torque KW (Normal Duty) N/A Filter N/A Variable Torque KW (Heavy Duty) 0.55 Supply 380...480V AC Phase Three Phase Conformal Coating N/A decorateTable('product-attribute-specs-table'); PDFs & Videos Downloads We currently have no 178B8577 manuals uploaded but you can contact our technical team for help.
Alternative Partnumber VLT2805PT4B20SBR0DBF00A00C1 Product Status Current Range VLT 2800 Range type Variable Speed Drive Communications Options N/A No Analog Inputs 2 No Digital Outputs 1 Relay Outputs 1 PTC/KTY Input N/A Pulse Output N/A NEMA N/A Logic Positive, Negative Protection N/A Width (mm) 75.0000 Height (mm) 200.0000 Weight (kg) N/A Constant Torque KW (Normal Duty) N/A Filter N/A Variable Torque KW (Heavy Duty) 0.55 Supply 380...480V AC Phase Three Phase Conformal Coating N/A