Fluke Calibration 2638A/05/C 120,HYDRA 2638A Data Logger, 22 CHANNEL, 120V with calibration
Precision data collection in a portable stand-alone system High-performance system accepts up to 22 inputs to measure voltage, current, resistance, temperature, and more Outstanding DC voltage accuracy of ±0.0024%! Features a dedicated 6.5-digit DMM Supports 15 common thermocouple types Data transfer to PC via USB memory stick or remote USB/LAN Set dual alarm set points for each channel to easily monitor data 20 on-board math channels with alarm settings for complex calculations 6 TTL Alarm outputs assignable to one or multiple channels Includes a calibration document supplied by the manufacturer Excellent accuracy, full-color display, easy-to-use menu system, and industrial safety ratings make the Hydra series III data acquisition system a standout in its class. This 22-channel (20 universal inputs and 2 dedicated low-burden current inputs) data logger with universal input module accepts AC/DC voltage, AC/DC current, resistance, frequency, thermocouple, RTD, and thermistor inputs. The Hydra series III system features a removable universal input module that plugs into a rear slot to give you the flexibility to leave your module at the test site, completely wired, and ready to use. When you need data from that site, simply "plug in" and load your saved setup file. The calibration date and input module serial number are programmed into the module and are read by the data logger when installed—ideal for collecting data in a regulated industry. A dedicated 6.5-digit multimeter provides additional functionality and value. On-screen color trend graphing and analysis offer multichannel real-time data display. Simply push a button to capture the chart results or data displays for reports or a closer review. Statistics include rate of change, Min, Max, standard deviation, average, sample size, and peak-to-peak information. A 20 MB on-board memory stores up to 75,000 data records. A built-in USB port collects and stores files up to 32 GB directly to a USB flash drive. What's included: input module, relay card, one pair of TL71 test leads, FlukeDAQ Lite software, screwdriver, power cord, and a calibration document supplied by the manufacturer.
Specifications Product Type Data Acquisition AC voltage accuracy ±0.11% AC current accuracy ±0.3% AC Max (Voltage) 300 V AC Min (Voltage) 100 mV DC current accuracy ±0.007% DC current range 100 µA to 100 mA DC voltage accuracy ±0.0024% DC voltage range 100 mV to 300 V Resistance range 100 ohm to 100 M ohm Frequency accuracy ±0.01% Frequency range 20 Hz to 1 MHz Temp accuracy Type J: ±0.60°C; Type K: ±0.53°C; Type T: ±0.62°C; RTD (Pt 100): ±0.016%; Thermistor: –40 to 150°C AC voltage range 100 mV to 300 V Power 100 to 240 VAV in four power model selections (100, 120, 220, and 240 VAC) Digits 6.5-digit for DMM Safety rating IEC Class II Display Full color, TFD (Thin Film Diode) Memory 75,000 scans; 1000 setup files Qty/ea 1 Math functions rate of change, min, max, standard deviation, average, sample size, and peak-to-peak information Temp range Type J: –210 to 1200°C; Type K: –270 to 1372°C; Type T: –270 to 400°C; also accepts Type R, S, N, E, B, C, D, G, L, M, U, W; RTD (Pt 100): –200 to 600°C; Thermistor: –40 to 150°C Dimensions (" L) 15-1/8 Dimensions (" W) 11-1/4 Dimensions (" H) 5-7/8 Manufacturer number 2638A/05/C 120
Recorders & Data Acquisition Data Acquisition Fluke 2638A/05 Hydra Series III 22-Channel Data Acquisition System and DMM