
SL Power ( Ault / Condor ) Power Products >> GLD140A 电源电源(AC-DC电源)-产品快照
- 品牌:
- SL Power ( Ault / Condor ) Power Products >>
- 型号:
- GLD140A
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
暂无展示,可咨询在线客服 | 400-811-6961 |
![]() |
产品介绍
SL Power ( Ault / Condor ) Power Products >> GLD140A 电源电源(AC-DC电源)
SL Power ( Ault / Condor ) GLD140A
SL Power ( Ault / Condor ) Power Products >>
SEE 744-0661 GLD140AG Overview 1% Output Regulation, 0.03%/°C (Typ.) Temperature Coefficient, Power Supply Specifications Input Current: Active power factor correction circuitry assures compliance with IEC1000-3-2, Class A. Maximum input current at minimum input voltage and full load is 3.0 A. Hold-Up Time: 26 ms total. 16 ms minimum from loss of AC input at full load until activation of the power fail signal. Output voltage remain within specified regulation limits for an additional 9 ms minimum after power fail activates. Output Noise: 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. Overvoltage Protection: Built-in on V1, 2 and 3 outputs. Output Regulation: Regulation for all outputs is the maximum deviation from initial set point under all line and load conditions. Initial set tolerance is measured with all outputs at 50% of full rated load. Specifications (Continued) Inrush Current: Inrush is limited by internal thermistors. The inrush at 240 VAC, averaged over the first AC half-cycle under cold start conditions will not exceed 37 A. EMI/EMC Compliance: All models including built-in EMI filtering to meet the following requirements:Conducted Emissions — EN55011, Class B; FCC Class BStatic Discharge — EN61000-4-2, Level 3RF Field Susceptibility — EN61000-4-3, Level 3Fast Transients/Bursts — EN61000-4-4, Level 3Surge Susceptibility — EN61000-4-5, Level 3Conducted RF Susceptibility — EN61000-4-6Voltage Sags and Surges — EN61000-4-11 Safety Agency Approvals: UL/EN/IEC 60601-1 and CSA22.2 No. 601-1. Features Compact Size: 4.5 × 8.5 × 1.95 Power Factor Corrected to IEC 1000-3-2 Class A Features (Continued) EMI Compliance to CISPR11, FCC Class B, IEC601-1-2 Approved to UL2601, IEC601-1 and CSA 22.2 No. 601.10M90 and EN60601: 1990 CE Marked to LVD
Brand/Series : GLD140 Series Configuration : Open Frame Current, Input : 3.0 A (Max.) Dimensions : 8.5" L x 4.5" H x 1.95" W in Efficiency : 73-85% Mounting Type : Panel Mount Number of Outputs : 4 Operation : Switching Output : 5VDC@16A, 12VDC@4A, 12VDC@6A, -12VDC@0.75A Power Rating : 140 W Power, Output : 140 W Power, Rating : 140 W Primary Type : AC-DC Regulation, Output : 1 % Special Features : PFC, Remote Sense Standards : CE Marked Temperature Coefficient : 0.03%⁄°C (Typ.) Temperature, Operating : 0 to +50 °C Type : Medical Voltage, Input : 90-246 VAC Voltage, Output : 5 VDC, 12 VDC, 12 VDC, -12 VDC Voltage, Output 1 : 5 V Voltage, Output 2 : 12 V Voltage, Output 3 : 12 V (C) Voltage, Output 4 : -12 V
Power Power Supply (AC-DC Power Supplies)