Mersen A6D90R 电源保险丝
Mersen A6D90R
Mersen A6D-R - Class RK1 - Time-Delay Fuse Specs: Volts (VAC) 600 Volts (VDC) 600 Ampere (A) 90 I.R. AC (kA) 200 I.R DC (kA) 100 IR Other (kA) 300kA 600VAC, Self Certified (UL Witnessed) Class Class RK1 Size per Standard Class RK1 Speed / Characteristic Time-Delay Mounting Clip Connection Terminal Type Ferrule, Blade Body Style Cylindrical, Rejection Body Material Polyester Materials Contact Tin-plated Copper Minimum Operating & Storage Temp °C -25 Ratings: UL Listed to Standard 248-12, File E2137, DC Listed to UL Standard 248, CSA Certified to Standard C22.2, No. 248.12 Description: Amp-Trap 2000 SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace obsolete 600V Class H, K or RK5 fuses already installed in the field. Solid-state SmartSpot indicator, Time-delay for motor starting and transformer inrush currents without nuisance opening, 300kA interrupting rating, self-certified (UL witnessed test, Extremely current-limiting for low peak let-thru current, Easy 2-to-1 selectivity for prevention of nuisance shut downs and "black outs", Rejection-style design prevents replacement errors (when used with recommended fuse blocks), High-visibility orange label gives instant recognition, Reduced inventory by taking the place of Class RK5, K, and H fuses, Metal embossed date and catalog number for easier traceability and lasting identification, Fiberglass body provides dimensional stability in harsh industrial settings, High-grade silica filler ensures fast arc quenching. Application Motors, Safety Switches, Transformers, Disconnects, Control Panels, All General-purpose Circuits. Mersen (also known as Ferraz Shawmut and Gould Fuses). Performance Data Performance Data-Peak Let Thru Data Sheet Application Guidelines Application Guidelines Brochure-Fuses Reference-Coordination Guide-Allen Bradley Reference-Coordination Guide-Cutler Hammer Reference-Coordination Guide-Square D
600V 90A Class RK1 Time-Delay Fuse Mersen A6D90R
Power Fuses