供应商名称 | 电话 | 备注 |
---|---|---|
福建萤光电气科技发展有限公司 | 18359060969 | |
福州福诺自动化设备有限公司 | 0591-87880180 | |
广州市西克传感器有限公司 | 4000121000 | |
买道传感科技(上海)有限公司 | 021-51872140 | |
上海桂伦自动化设备有限公司 | 021-56519159 | |
深圳市中南科达科技有限公司 | 0755-86110175 | |
深圳市洲其电气自动化设备有限公司 | 0755-26016618 | |
深圳市丰德锐科技有限公司 | 0755-82526060 | |
上海锝秉工控设备有限公司 | 021-39520660 | 工业自动化控制 |
产品介绍
SICK施克 6047602 温度传感器
Sick THTS-1PA542006MZ (6047602)
Sick
Sick THTS-1PA542006MZ (6047602) ; Pt100 element, accuracy class A (IEC 60751) Measuring ranges -50 °C ... +150 °C and -50 °C … +250 °C Wetted parts: Corrosion-resistant stainless steel 316L/1.4435, Ra = 0.8 µm Various hygienic process connections and insertion lengths Pt100 (4-wire) or 4 mA … 20 mA (2-wire) Round connector M12 x 1 Your benefits Convenient system integration – installation in narrow installation space possible through compact dimensions Safe, hygienic operation due to wetted parts made from high-grade stainless steel, hygienically-graded surface finish and a gap- and crevice-free design Rugged: Connection housing is easily cleaned and splash proof Quick and safe installation Very good long-term stability, accuracy and linearity Quick response time Optimal solutions for individual requirements due to versatile configurability Features Measurement range: -50 °C ... 150 °C Sensor element: Pt100 Output signal: Pt100, 4-wire Performance Accuracy of sensor element: Class A according to IEC 60751 Transmitter accuracy: ≤ ± 0.2 % of span Transmitter linearity: ≤ ± 0.1 % of span Response time: Response time t50: ≤ 3.3 s response time t90: ≤ 9.7 s 1) 1) Depending on sensor configuration, according to IEC 60751 Mechanics/electronics Process connection: Conical coupling (DIN 11851) DN 40 with union nut Insertion length/diameter of probe: 200 mm / 6 mm Housing material: Stainless steel 1.4571 (316Ti) Wetted parts: stainless steel 1.4435 (316L), Ra ≤ 0.8 µm Electrical connection/enclosure rating 1) : Round connector M12 x 1, 4-pin / IP 68 and IP 69K Measuring current: 0.3 mA ... 1 mA Electrical safety: Dielectric strength: 500 V AC Protection class: III Protection class III: Pressure resistance: max. 40 bar 1) Enclosure rating IP per IEC 60529. The enclosure rating classes specified only apply while the pressure transmitter is connected with female connectors that provide the corresponding enclosure rating. Ambient data Ambient temperature: -40 °C ... 85 °C Storage and transport temperature: -40 °C ... 85 °C Vibration resistance according to IEC 60751: 3 g Shock resistance: According to IEC 60751 Relative humidity: ≤ 95 %
Products specifications Manufacturer category Sick THT Manufacturer Sick
Temperature Sensors Temperature Sensors