SICK施克 1040173 光栅-产品快照
- 品牌:
- SICK
- 型号:
- 1040173
- 重量:
- 1.997 kg
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
福建萤光电气科技发展有限公司 | 18359060969 | |
福州福诺自动化设备有限公司 | 0591-87880180 | |
广州市西克传感器有限公司 | 4000121000 | |
买道传感科技(上海)有限公司 | 021-51872140 | |
上海桂伦自动化设备有限公司 | 021-56519159 | |
深圳市中南科达科技有限公司 | 0755-86110175 | |
深圳市洲其电气自动化设备有限公司 | 0755-26016618 | |
深圳市丰德锐科技有限公司 | 0755-82526060 | |
上海锝秉工控设备有限公司 | 021-39520660 | 工业自动化控制 |
产品介绍
SICK施克 1040173 光栅
Sick C46S-0901CT400 (1040173)
Sick
Safety Light Curtain C4000 Standard / Advanced Guest Emitter C46S-0901CT400 900mm protection field height, 14mm resolution Range 0...8 m System connection: M12 x 7 + FE Fixed connection cable: 320mm ; 7-segment display Beam coding for correct system allocation Cascadable up to three systems PSDI mode with the UE402 switching amplifier Configuration and diagnostics via PC ADO (Application Diagnostic Output) signaling output for contamination indicator External device monitoring (EDM) and restart interlock (RES) Accessory Clone Plug - for configuration memory Your benefits 7-segment display saves time during alignment and diagnostics Beam coding protects the systems against opticalinterference by ensuring a high level of availability Ability to cascade up to three systems optimizes the safety application and reduces wiring costs Preconfigured light curtains and the clone plug enables easy and rapid commissioning Precise, convenient configuration and diagnostics reduces downtime Functions-Sender Beam coding: Beam coding (delivery status): Non-coded Configuration method: PC with CDS (Configuration and Diagnostic Software) Extension connection: - Safe device communication via EFI/SDL: - Functions-Receiver Restart interlock: - External device monitoring: - Beam coding: Beam coding (delivery status): Non-coded Bypass (with UE402): - Emergency stop / bypass at extension connection: - Operating mode switching (with UE402): - Reduced resolution: - Muting with: Flexi Classic Configuration method: PC with CDS (Configuration and Diagnostic Software) Extension connection: - Safe device communication via EFI/SDL: - Technical Data-Sender Protective field height: 900 mm Resolution: 14 mm Housing length: 980 mm Housing cross-section: 48 mm x 40 mm Type: Type 4 (IEC 61496) Safety integrity level: SIL3 (IEC 61508), SILCL3 (IEC 62061) Category: category 4 (EN ISO 13849) Performance level: PL e (EN ISO 13849) PFHd: 1.5 * 1E-08 TM (Mission Time): 20 a Enclosure rating: IP 65 Protection class: III Ambient operating temperature from ... to: 0 °C ... 55 °C Vibration resistance (checked to): 5 g (IEC 60068-2-6) Oscillation frequency from ... to: 10 Hz ... 55 Hz Shock resistance: 10 g, 16 ms (IEC 60068-2-29) Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC Power consumption: ≤ 2 A Wave length: 950 nm Connection type: fixed connection cable 320 mm with plug M12 x 7 + FE, straight Maximum connection cable cross-section: 0.25 mm2 Technical Data-Receiver Protective field height: 900 mm Resolution: 14 mm Scanning range from ... to: 0 m ... 8 m Scanning range from ... to (delivery status): 0 m ... 2.5 m Housing length: 980 mm Housing cross-section: 48 mm x 40 mm Type: Type 4 (IEC 61496) Safety integrity level: SIL3 (IEC 61508), SILCL3 (IEC 62061) Category: category 4 (EN ISO 13849) Performance level: PL e (EN ISO 13849) PFHd: 1.5 * 1E-08 TM (Mission Time): 20 a Enclosure rating: IP 65 Protection class: III Ambient operating temperature from ... to: 0 °C ... 55 °C Vibration resistance (checked to): 5 g (IEC 60068-2-6) Oscillation frequency from ... to: 10 Hz ... 55 Hz Shock resistance: 10 g, 16 ms (IEC 60068-2-29) Response time without beam coding: ≤ 17 ms Response time with beam coding: ≤ 33 ms Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC Power consumption: ≤ 3 A Maximum switching current: 500 mA Wave length: 950 nm Connection type: fixed connection cable 320 mm with plug M12 x 7 + FE, straight Maximum connection cable cross-section: 0.25 mm2
Products specifications Manufacturer category Sick C4000 Manufacturer Sick
Safety Barriers Safety Barriers