产品介绍
LEUZE劳易测 66076100
Leuze MLD335-R2L: Multiple Light Beam Safety Device Receiver – 66076100
66076100
Multiple light beam safety device receiver, compatible with MLD 300 series, type 2, 2 beams, 500mm beam spacing, supply voltage: 24 VDC -20 – 20 % , M12 thread size, IP 67 protection , Product Description Series: MLD 300 Device type: Receiver Number of beams: 2 beams Beam spacing: 500 mm Response time: 50 ms Restart delay time: 100 ms Supply voltage: 24 VDC, -20-20% Number of safety-related switching outputs (OSSDs): 2 outputs Number of digital switching outputs: 1 output Switching voltage high, min: 18.2 V Switching voltage low, max: 2.5 V Switching voltage, type: 23 V Voltage type: DC Switching element for outputs: Transistor, PNP Connection 1 thread size: M12 Type of display: LED Number of LEDs: 2 Degree of protection: IP 67 Certifications: c CSA US, c TUV NRTL US, TUV SUd Functions: Contactor monitoring (EDM), selectable, Timing controlled 2-sensor muting, Sequence controlled 2-sensor muting, Timing controlled 4-sensor muting, Muting enable function, Muting-timeout extension, Alternative connection for second muting signal, Partial muting, Start/restart interlock (RES) Special design: Reflective element for laser alignment aid Like the protective sensors of the MLD 500 series (type 4), these type 2 multiple light beam safety devices are also available in various function classes (MLD 310, 312, 320, 330, 335). Configuration via PC or DIP switch is not necessary. Advantages: Through extensive functions, such as start/restart interlock, contactor monitoring, timing controlled 2-sensor muting, sequence controlled 2-sensor muting and timing controlled 4-sensor muting, these multiple light beam safety devices can be used in different areas. The configuration is simply performed by means of wiring, i. e. no software, PC or DIP switch are necessary The use at ambient temperatures as low as -30 degrees Celsius is possible Start/restart interlock (RES), selectable Contactor monitoring (EDM), selectable Configurable operating modes Integrated muting function, no additional muting module is necessary 2-sensor muting, (timing controlled, sequence controlled) Timing controlled 4-sensor muting Options: integrated laser alignment aid, integrated muting indicator, 7?segment display Click to download the Leuze MLD 300 Instruction Manual
Categories: Brands , Leuze , Leuze MLD 300: Type 2 Multiple Light Beam Safety Devices , Multiple Light Beam Safety Devices , Optoelectronic Safety Sensors , Safety Products