Phoenix Contact菲尼克斯 2986575 继电器-产品快照
- 品牌:
- Phoenix Contact
- 型号:
- 2986575
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
菲尼克斯(中国)投资有限公司 | 025-52121888 | |
西连电气(上海)有限公司 | 021-80181890 | 工业连接器供应商 |
上海积进自动化设备有限公司 | 021-34273201 | |
上海北上自动化设备有限公司 | 400 7720 262 | |
南京瀚德电子科技有限公司 | 025-86368030 | 电气连接解决方案 |
工控网(北京)电子商务有限公司 | 400-102-5068 | |
上海贸泽电子有限公司 | ||
欧时电子元件(上海)有限公司 | ||
深圳市仕达威实业有限公司 | 400-800-8619 | 德国工业品一站式采购 |
众业达电气股份有限公司 | 4008018988 | |
福州福大自动化科技有限公司 | 0591-28482265 | |
北京京北通宇电子元件有限公司 | 010-82743622 | 国际电子元器件采购服务 |
产品介绍
Phoenix Contact菲尼克斯 2986575 继电器
PSR-SCP Safety Relay, 24 V dc, 3 Safety
Phoenix Contact
PSR Safety Relays for the Process Industry Failsafe controllers are used as standard in process engineering. In this context, the use of safe coupling relays for power adjustment and the electrical isolation of actuators is gaining in significance, as actuators often need more current or other voltages than the controllers are able to supply. Furthermore, the digital outputs of failsafe controllers run automatic self-tests at regular intervals in order to detect faults. However, the test pulses involved usually cause premature wear of the relays. With their integrated test pulse filter and control circuit to adjust power consumption, all FSP devices take these special requirements of a failsafe controller into account. Emergency Stop Coupling RelayConnects digital output signals from fail safe controllers to the peripherals (valves, etc.) for electrical isolation and power adaptationOne enabling current path (768-5134 & 801-6075)Two enabling current paths (712-5263, 712-5266, 712-5260 & 712-5279)17.5 mm slim housingLong service life thanks to filtering of controller test pulsesWith installed and replaceable fuse in the enabling current pathForcibly guided contacts according to EN 50205Simple proof test as per IEC 61508 due to integrated signalling contactUp to SIL 2 according to IEC 61508 (712-5263 & 712-5266)Up to SIL 3 according to IEC 61508 (768-5134, 801-6075, 712-5260 & 712-5279) Emergency Stop and Safety Door MonitoringOne and two channel control (666-7084 & 801-5956)One channel control (666-7022 & 801-5930)Manual and automatic activationMax. 3 enabling current paths24-230V wide-range input (666-7084 & 801-5956)With switch-on current reduction, thus suitable for connecting to failsafe controllers (PSR-ESP4)Up to Cat. 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508 F&G coupling relay for failsafe controllersCouples digital output signals to I/O devices (valves, etc.) for electrical isolation and power adaptationLong service life, thanks to integrated test pulse filtersConnectable, configurable open circuit and load monitoringSpecial design for avoiding spurious trips1 enabling current path (767-6180 & 767-6184)17.5 mm narrow housingUp to SIL 3 according to IEC 61508 (low demand) Approvals UL, cUL, TÜV, GOST. Standards DIN EN 50178, VDE 0160. Safety Relay ; Supply Voltage 24 V dc; SIL IEC 61508 2; Safety Contacts 3; Terminal Type Screw Clamp; Width 17.5mm; CAD Drawing 3D CAD Model; Length 99mm; Depth 114.5mm; Series PSR-SCP;
Safety Relays